Product Overview
Features
- 5.7kW 3 phase 208/120V Metered Power Distribution Unit / PDU
- Set of 3 built-in current meters continuously report input current per phase
- Attached NEMA L21-20P 20A (3P+N+E) 208V 3 phase input plug with 6 ft. / 1.8m cord
- 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
- 27 total outlets arranged in three single phase output load banks
- 6 NEMA L6-20R outlets output 208V
- 21 NEMA 5-15/20R outlets output 120V
- Included cord retention brackets keep vital network equipment plugged in and continuously powered
- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)
- Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Specifications
OVERVIEW
| UPC Code | 037332163905 |
| PDU Type | Metered |
INPUT
| PDU Input Voltage | 208/120V |
| Recommended Electrical Service | Three-phase 20A 208V service |
| Maximum Input Amps | 16 |
| PDU Plug Type | NEMA L21-20P |
| Input Phase | 3-Phase |
| Input Cord Length (ft.) | 6 |
OUTPUT
| Output Capacity Details | 5.7kW (208/120V) total capacity; 9.2A (208V) max per output phase (L1-L2, L2-L3, L3-L1) / 16A (120V) max per output phase (L1, L2, L3) |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacle Details | 5-15/20R outlets provide 120V output; L6-20R outlets provide 208V output |
| Output Receptacles | (21) 5-15/20R; (6) L6-20R |
| Output Nominal Voltage | 208/120V |
USER INTERFACE, ALERTS & CONTROLS
| Reported Load Segments | Supports local monitoring current for each input phase (9.2A balanced max per L1, L2 and L3); Outlets are color-coded and labeled for easy phase and load bank identification; L1-L2 feeds 2 L6-20R outlets; L2-L3 feeds 2 L6-20R outlets; L3-L1 feeds 2 L6-20R outlets; L1-N feeds black 5-20R outlets, Phase L2-N feeds dark-gray 5-20R outlets, Phase L3-N feeds light-gray 5-20R outlets |
| Front Panel LCD Display | Set of 3 digital current meters report input current per phase |
PHYSICAL
| Material of Construction | Metal |
| Form Factors Supported | Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks |
| PDU Form Factor | Vertical (0U) |
| Shipping Dimensions (hwd / in.) | 5.20 x 6.70 x 76.50 |
| Shipping Weight (lbs.) | 14.50 |
| Unit Dimensions (hwd / in.) | 70 x 2.2 x 1.71 |
| Unit Weight (lbs.) | 12.6 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +60°C (-22°F to +140°F) |
| Relative Humidity | 5-95% non-condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
STANDARDS & COMPLIANCE
| Certifications | Tested to UL60950-1 (USA, Canada), NOM (Mexico), Class A (Emissions), ROHS, TAA Compliant |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |
Features
- 5.7kW 3 phase 208/120V Metered Power Distribution Unit / PDU
- Set of 3 built-in current meters continuously report input current per phase
- Attached NEMA L21-20P 20A (3P+N+E) 208V 3 phase input plug with 6 ft. / 1.8m cord
- 0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
- 27 total outlets arranged in three single phase output load banks
- 6 NEMA L6-20R outlets output 208V
- 21 NEMA 5-15/20R outlets output 120V
- Included cord retention brackets keep vital network equipment plugged in and continuously powered
- Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)
- Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Specifications
OVERVIEW
| UPC Code | 037332163905 |
| PDU Type | Metered |
INPUT
| PDU Input Voltage | 208/120V |
| Recommended Electrical Service | Three-phase 20A 208V service |
| Maximum Input Amps | 16 |
| PDU Plug Type | NEMA L21-20P |
| Input Phase | 3-Phase |
| Input Cord Length (ft.) | 6 |
OUTPUT
| Output Capacity Details | 5.7kW (208/120V) total capacity; 9.2A (208V) max per output phase (L1-L2, L2-L3, L3-L1) / 16A (120V) max per output phase (L1, L2, L3) |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacle Details | 5-15/20R outlets provide 120V output; L6-20R outlets provide 208V output |
| Output Receptacles | (21) 5-15/20R; (6) L6-20R |
| Output Nominal Voltage | 208/120V |
USER INTERFACE, ALERTS & CONTROLS
| Reported Load Segments | Supports local monitoring current for each input phase (9.2A balanced max per L1, L2 and L3); Outlets are color-coded and labeled for easy phase and load bank identification; L1-L2 feeds 2 L6-20R outlets; L2-L3 feeds 2 L6-20R outlets; L3-L1 feeds 2 L6-20R outlets; L1-N feeds black 5-20R outlets, Phase L2-N feeds dark-gray 5-20R outlets, Phase L3-N feeds light-gray 5-20R outlets |
| Front Panel LCD Display | Set of 3 digital current meters report input current per phase |
PHYSICAL
| Material of Construction | Metal |
| Form Factors Supported | Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks |
| PDU Form Factor | Vertical (0U) |
| Shipping Dimensions (hwd / in.) | 5.20 x 6.70 x 76.50 |
| Shipping Weight (lbs.) | 14.50 |
| Unit Dimensions (hwd / in.) | 70 x 2.2 x 1.71 |
| Unit Weight (lbs.) | 12.6 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +60°C (-22°F to +140°F) |
| Relative Humidity | 5-95% non-condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
STANDARDS & COMPLIANCE
| Certifications | Tested to UL60950-1 (USA, Canada), NOM (Mexico), Class A (Emissions), ROHS, TAA Compliant |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |