8.6kW 3 phase 208/120V Local Metered Power Distribution Unit / PDU
Set of 3 built-in current meters continuously report input current per phase
Attached NEMA L21-30P 30A (3P+N+E) 208V 3 phase input plug with 6 ft. / 1.8m cord
0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
48 total outlets arranged in three breakered single phase output load banks
36 C13 and 6 C19 outlets output 208V
6 NEMA 5-15/20R outlets output 120V
Included cord retention brackets keep vital network equipment plugged in and continuously powered
Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)
Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Package Includes
Local Metered Rackmount PDU with pre-installed mounting buttons
Cord retention brackets
Spare installation buttons (2 9mm / 4 6mm)
Rack mounting brackets
Owner's manual
Specifications
OVERVIEW
UPC Code
037332163875
PDU Type
Local Metered
INPUT
PDU Input Voltage
208
Recommended Electrical Service
Three-phase 30A 208V service
Maximum Input Amps
24
Maximum Input Amps Details
Agency de-rated to 24A continuous
PDU Plug Type
NEMA L21-30P
Input Phase
3-Phase
Input Cord Length (ft.)
6
OUTPUT
Output Capacity Details
8.6kW (208V) total capacity; 13.9A (208V) max per output phase (L1-L2, L2-L3, L3-L1) / 16A (120V) max per output phase (L1, L2, L3); 12A max per C13 outlet; 16A max per 5-20R outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacle Details
5-15/20R outlets provide 120V output; C13 and C19 outlets provide 208V output
Output Receptacles
(6) 5-15/20R; (36) C13; (6) C19
Output Nominal Voltage
208/120V
Overload Protection
3 20A double-pole circuit breakers (1 per output phase)
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments
Supports monitoring of input current per phase (13.8A balanced max per L1, L2 and L3); Outlets are color-coded and labeled for phase and load bank identification; Phase L1-L2 feeds black C13 & C19 outlets; Phase L2-L3 feeds dark-gray C13 & C19 outlets; Phase L3-L1 feeds light-gray C13 & C19 outlets; Phase L1-N feeds black 5-20R outlets; Phase L2-N feeds dark-gray 5-20R outlets; Phase L3-N feeds light-gray 5-20R outlets
Front Panel LCD Display
Set of 3 digital current meters report input current in amps (L1, L2, L3)
PHYSICAL
Material of Construction
Metal
Form Factors Supported
Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
PDU Form Factor
Vertical (0U)
Shipping Dimensions (hwd / in.)
6.00 x 10.00 x 77.30
Shipping Weight (lbs.)
19.50
Unit Dimensions (hwd / in.)
70 x 2.2 x 1.71
Unit Weight (lbs.)
13.90
ENVIRONMENTAL
Operating Temperature Range
0C ~ 40C (32F ~ 104F)
Storage Temperature Range
-30°C to +60°C (-22°F to +140°F)
Relative Humidity
5-95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
STANDARDS & COMPLIANCE
Certifications
Tested to UL62368-1 (USA, Canada), NOM (Mexico), RETIE (Columbia), Class A (Emissions), ROHS, TAA Compliant