Product Overview
Features
- Tripp Lite SMX500RT1U .5 kVA / 500VA / 300 watt line interactive UPS
- 1U rack / tower compatible form factor
- IEC C14 input; 6 IEC C13 output receptacles
- Installed depth of only 11.8 in / 29.8 cm
- Large internal batteries offer runtimes of 14.6 minutes at half load (250VA/150 watts) and 3.2 minutes at full load (500VA/300 watts)
- Intelligent battery management system extends battery life
- Maintains regulated 230V nominal output during brownouts as low as 187V
- Includes 6 UPS-supported outlets, with one single-outlet load bank for remote load shedding or rebooting of an individual device
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
- Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
- PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
- IP-based Auto Probe detects lost connectivity and restores service autonomously
- Supports Tripp Lite's WatchDog software application to restore operation to locked equipment through soft reboot of application, OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications (requires optional WATCHDOGSW)
- Emergency Power Off (EPO) interface with cable
- Multi-function audible alarms and set of 5 front panel LEDs
- C14 inlet accepts user-supplied AC power cord with country specific plug
- Network-grade AC surge suppression
- Field-replaceable, hot-swappable internal UPS batteries
- Optional PDUBHV10 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
Specifications
OVERVIEW
| UPC Code | 037332119254 |
| UPS Type | Line-Interactive |
INPUT
| Rated input current (Maximum Load) | 7A (Maximum input with 300W UPS and 1310W surge-only loads) |
| Nominal Input Voltage(s) Supported | 230V AC |
| Nominal Input Voltage Description | Accepts inputs between 187 and 265V for AC mode operation |
| UPS Input Connection Type | C14 inlet |
| UPS Input Connection Description | C14 inlet accepts user-supplied AC power cord with country-specific plug; Includes 2 1.8m C13 to C14 power cables |
| Input Circuit Breakers | 7A thermal breaker |
| Input Phase | Single-Phase |
OUTPUT
| Output Volt Amp Capacity (VA) | 500 |
| Output Watt Capacity (Watts) | 300 |
| Power Factor | 0.6 |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection; 50Hz (46-54Hz) / 60Hz (56-64Hz) |
| Output Voltage Regulation (Line Mode) | -8%, +15% |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Included Output Power Cables | Two 1.8m IEC320-C13 to C14 load jumper cables |
| UPS Output Receptacles (Surge Suppression Only) | 5 UPS outlets, 1 surge-only outlet |
| Load Management Receptacles | One switchable single-outlet C13 load bank |
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Output Receptacles | (6) C13 |
| Output Amp Capacity | 2.17A maximum (UPS outlets) / 7A maximum (UPS + Surge-only Outlets) |
| Individually Controllable Load Banks | Yes |
BATTERY
| Full Load Runtime (min.) | 3 min. (300w) |
| Half Load Runtime (min.) | 14 min. (150w) |
| Expandable Runtime | No |
| DC System Voltage (VDC) | 12 |
| Battery Recharge Rate (Included Batteries) | Less than 12 hours to 90% |
| Battery Access | Battery access door |
| Internal UPS Replacement Battery Cartridge | IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMX500RT1U models with the Series Number AG-03AD listed on the UPS nameplate (Sold since 2021); For all prior versions of SMX500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additonal information |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 187 |
| Undervoltage Correction | Input voltages between 187 and 215 are boosted by 14% |
USER INTERFACE, ALERTS & CONTROLS
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 480 |
| EMI / RFI AC Noise Suppression | Yes |
PHYSICAL
| Primary Form Factor | Rackmount; Tower |
| Included Mounting Accessory Description | Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (inches) | 14.6 |
| Primary UPS Depth (mm) | 286 |
| Primary UPS Height (mm) | 44 |
| Primary UPS Width (mm) | 440 |
| Rack Height | 1U |
| Shipping Dimensions (hwd / in.) | 4.20 x 15.80 x 21.00 |
| Shipping Weight (lbs.) | 17.70 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd, in.) | 1.73 x 17.32 x 11.26 |
| UPS Power Module Weight (kg) | 8.03 |
| UPS Power Module Weight (lbs.) | 17.7 |
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 35 |
| AC Mode Efficiency Rating (100% Load) | 97% |
| Audible Noise | 45 dBA maximum, front side 1m |
COMMUNICATIONS
| Network Management Cards | WEBCARDLX |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Communications Cable | USB and DB9 cabling included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Network Management Card Description | Network management card optional |
| Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
LINE / BATTERY TRANSFER
| Transfer Time | 2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 187 |
| High Voltage Transfer to Battery Power (Setpoint) | 264 |
FEATURES & SPECIFICATIONS
| Grounding Lug | Back panel grounding lug |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
STANDARDS & COMPLIANCE
| UPS Certifications | CE; ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to UL1778 (USA) |
| Certification Details | Series Number (s) AG-03AD; Safety Standards (Canada) CAN/CSA-C22.2 No. 107.3-14 (3rd Ed); Safety Standards (U.S.) UL1778:2014 (5th Ed) R10.17; Safety Standards (International) EN62040-1:2008+A1:2013; IEC62040-1:2008 (1st Ed)+A1:2013; EMI/EMC Standards Class B; EN62040-1:2006; IEC62040-2:2005 (2nd Ed)+Cor.1:2011 |
WARRANTY
| Product Warranty Period (International) | 2-year limited warranty |
Features
- Tripp Lite SMX500RT1U .5 kVA / 500VA / 300 watt line interactive UPS
- 1U rack / tower compatible form factor
- IEC C14 input; 6 IEC C13 output receptacles
- Installed depth of only 11.8 in / 29.8 cm
- Large internal batteries offer runtimes of 14.6 minutes at half load (250VA/150 watts) and 3.2 minutes at full load (500VA/300 watts)
- Intelligent battery management system extends battery life
- Maintains regulated 230V nominal output during brownouts as low as 187V
- Includes 6 UPS-supported outlets, with one single-outlet load bank for remote load shedding or rebooting of an individual device
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX and SNMPWEBCARD
- Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
- PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
- IP-based Auto Probe detects lost connectivity and restores service autonomously
- Supports Tripp Lite's WatchDog software application to restore operation to locked equipment through soft reboot of application, OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications (requires optional WATCHDOGSW)
- Emergency Power Off (EPO) interface with cable
- Multi-function audible alarms and set of 5 front panel LEDs
- C14 inlet accepts user-supplied AC power cord with country specific plug
- Network-grade AC surge suppression
- Field-replaceable, hot-swappable internal UPS batteries
- Optional PDUBHV10 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
Specifications
OVERVIEW
| UPC Code | 037332119254 |
| UPS Type | Line-Interactive |
INPUT
| Rated input current (Maximum Load) | 7A (Maximum input with 300W UPS and 1310W surge-only loads) |
| Nominal Input Voltage(s) Supported | 230V AC |
| Nominal Input Voltage Description | Accepts inputs between 187 and 265V for AC mode operation |
| UPS Input Connection Type | C14 inlet |
| UPS Input Connection Description | C14 inlet accepts user-supplied AC power cord with country-specific plug; Includes 2 1.8m C13 to C14 power cables |
| Input Circuit Breakers | 7A thermal breaker |
| Input Phase | Single-Phase |
OUTPUT
| Output Volt Amp Capacity (VA) | 500 |
| Output Watt Capacity (Watts) | 300 |
| Power Factor | 0.6 |
| Nominal Voltage Details | 230v nominal inverter output voltage |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection; 50Hz (46-54Hz) / 60Hz (56-64Hz) |
| Output Voltage Regulation (Line Mode) | -8%, +15% |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| Included Output Power Cables | Two 1.8m IEC320-C13 to C14 load jumper cables |
| UPS Output Receptacles (Surge Suppression Only) | 5 UPS outlets, 1 surge-only outlet |
| Load Management Receptacles | One switchable single-outlet C13 load bank |
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Output Receptacles | (6) C13 |
| Output Amp Capacity | 2.17A maximum (UPS outlets) / 7A maximum (UPS + Surge-only Outlets) |
| Individually Controllable Load Banks | Yes |
BATTERY
| Full Load Runtime (min.) | 3 min. (300w) |
| Half Load Runtime (min.) | 14 min. (150w) |
| Expandable Runtime | No |
| DC System Voltage (VDC) | 12 |
| Battery Recharge Rate (Included Batteries) | Less than 12 hours to 90% |
| Battery Access | Battery access door |
| Internal UPS Replacement Battery Cartridge | IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMX500RT1U models with the Series Number AG-03AD listed on the UPS nameplate (Sold since 2021); For all prior versions of SMX500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additonal information |
| Battery Replacement Description | Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 187 |
| Undervoltage Correction | Input voltages between 187 and 215 are boosted by 14% |
USER INTERFACE, ALERTS & CONTROLS
| Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power-failure, overload and low-battery conditions |
| LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 480 |
| EMI / RFI AC Noise Suppression | Yes |
PHYSICAL
| Primary Form Factor | Rackmount; Tower |
| Included Mounting Accessory Description | Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations |
| Installation Form Factors Supported with Included Accessories | 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower |
| Minimum Required Rack Depth (inches) | 14.6 |
| Primary UPS Depth (mm) | 286 |
| Primary UPS Height (mm) | 44 |
| Primary UPS Width (mm) | 440 |
| Rack Height | 1U |
| Shipping Dimensions (hwd / in.) | 4.20 x 15.80 x 21.00 |
| Shipping Weight (lbs.) | 17.70 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (hwd, in.) | 1.73 x 17.32 x 11.26 |
| UPS Power Module Weight (kg) | 8.03 |
| UPS Power Module Weight (lbs.) | 17.7 |
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 35 |
| AC Mode Efficiency Rating (100% Load) | 97% |
| Audible Noise | 45 dBA maximum, front side 1m |
COMMUNICATIONS
| Network Management Cards | WEBCARDLX |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Communications Cable | USB and DB9 cabling included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| Network Management Card Description | Network management card optional |
| Communications Interface | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
LINE / BATTERY TRANSFER
| Transfer Time | 2-4 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 187 |
| High Voltage Transfer to Battery Power (Setpoint) | 264 |
FEATURES & SPECIFICATIONS
| Grounding Lug | Back panel grounding lug |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Hot swappable batteries; Remote management; Surge/noise protection |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
STANDARDS & COMPLIANCE
| UPS Certifications | CE; ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to UL1778 (USA) |
| Certification Details | Series Number (s) AG-03AD; Safety Standards (Canada) CAN/CSA-C22.2 No. 107.3-14 (3rd Ed); Safety Standards (U.S.) UL1778:2014 (5th Ed) R10.17; Safety Standards (International) EN62040-1:2008+A1:2013; IEC62040-1:2008 (1st Ed)+A1:2013; EMI/EMC Standards Class B; EN62040-1:2006; IEC62040-2:2005 (2nd Ed)+Cor.1:2011 |
WARRANTY
| Product Warranty Period (International) | 2-year limited warranty |