The PDUH30HV 5.8kW Single-Phase 200-240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUH30HV features 10 total outlets—two in front and eight in the rear. The NEMA L6-30P input plug with 12-ft. (3.66 m) cord connects to your facility's compatible AC power source, generator or protected UPS to distribute power to connected equipment.
The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 20A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA-standard 19-inch racks, under a counter or on a wall or workbench.
Features
Reliable Single-Phase 24A 208/240V Power Distribution
Ideal no-frills PDU for data centers, server rooms and network wiring closets
10 total C13 outlets—8 rear and 2 front
NEMA L6-30P input plug with 12-ft. (3.66 m) power cord
Rear-panel grounding lug
Dual 20A circuit breakers protect against overloads
Switchless Design
Prevents accidental shutdowns and costly downtime
Versatile Installation Options
Reversible all-metal housing faces front or rear in rack
Supports 1U horizontal or 0U vertical mounting in EIA-standard 19 in. racks
Also mounts on wall, workbench or under a counter
Package Includes
PDUH30HV 5.8kW Single-Phase 200-240V Basic PDU
Mounting hardware
Owner’s manual
Specifications
OVERVIEW
UPC Code
037332183217
PDU Type
Basic
INPUT
PDU Input Voltage
200; 208; 220; 230; 240
Recommended Electrical Service
Single-phase 30A 200-240V service
Maximum Input Amps
24
Maximum Input Amps Details
Agency de-rated to 24A continuous
PDU Plug Type
NEMA L6-30P
Input Phase
Single-Phase
Input Cord Length (ft.)
12
OUTPUT
Output Capacity Details
5.8kW (240V), 5.5kW (230V), 5.3kW (220V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 12A max per C13 outlet
Frequency Compatibility
50 / 60 Hz
Output Receptacle Details
8 front-facing and 2 rear-facing outlets (reversible)
Output Receptacles
(10) C13
Output Nominal Voltage
200-240V
Overload Protection
Two 20A breakers protect 5 outlets each
PHYSICAL
Material of Construction
Metal
Form Factors Supported
1U rackmount, 0U vertical mount, wallmount and under-counter
Minimum Required Rack Depth (inches)
6
PDU Form Factor
Horizontal (1U)
Shipping Dimensions (hwd / in.)
3.00 x 20.25 x 11.25
Shipping Weight (lbs.)
8.49
Unit Dimensions (hwd / in.)
1.75 x 17.5 x 3.75
Unit Weight (lbs.)
7.8
ENVIRONMENTAL
Operating Temperature Range
0C ~ 40C (32F ~ 104F)
Storage Temperature Range
-30°C to +50°C (-22°F to +122°F)
Relative Humidity
5-95% non-condensing
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding
Grounding lug
STANDARDS & COMPLIANCE
Certifications
Tested to UL62368-1:2014 (2nd Ed) (USA), CAN/CSA-C22.2 No. 62368-1-14 (Canada), NOM (Mexico), Class A (Emissions), ROHS, TAA Compliant;