Tripp-Lite PDU12IEC Basic 100V - 240V 16A Horizontal 1URM PDU

$268.99
SKU:
PDU12IEC
Shipping:
Calculated at Checkout
Product Type:
Single Phase PDU

Product Overview

Overview

The PDU12IEC 1.9/3.8kW Single-Phase 120–240V Basic PDU is the perfect no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Perfectly suited for high-density IT environments, the PDU12IEC features a single load bank with 14 total outlets—eight rear C13, two rear C19 and four front C13. The C20 inlet accepts a variety of user-provided power cords that connect to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment.

The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 16A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing mounts in 1U of space in EIA-standard 19-inch racks, as well as on a wall or workbench or under a counter. With a compatible rack and Tripp Lite’s PDUSIDEBRKT accessory (sold separately), you can adapt the PDU12IEC for vertical 0U rack-mounting.

Features

Reliable Single-Phase Power Distribution
  • Ideal no-frills PDU for networking, telecom, security, audio/video and sound reinforcement applications
  • 14 total outlets—8 rear C13, 2 rear C19 and 4 front C13—in one load bank
  • Built-in 16A circuit breakers protect outlets against overloads
  • C20 inlet accepts wide variety of user-supplied power cords
  • Rear-panel grounding lug

Switchless Design
  • Prevents accidental shutdowns and costly downtime

Versatile Installation Options
  • Mounts horizontally in 1U of EIA-standard 19 in. 2- and 4-post racks
  • Reversible all-metal housing faces front or rear in rack
  • Ready for toolless 0U vertical installation with optional PDUSIDEBRKT (sold separately)
  • Also mounts on wall, workbench or under a counter

Package Includes

  • PDU12IEC 1.9/3.8kW Single-Phase 120–240V Basic PDU
  • Mounting hardware
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332116253
PDU Type Basic
INPUT
PDU Input Voltage 120; 125; 127; 200; 208; 220; 230; 240
Recommended Electrical Service Single-phase 16/20A 120-240V service
Maximum Input Amps 16
Maximum Input Amps Details Agency derated to 16A continuous (North America only)
PDU Plug Type IEC-320 C20
Input Phase Single-Phase
Input Cord Details C20 inlet accepts user supplied input cable with C19 output connection
Input Cord Length (ft.) 0
OUTPUT
Output Capacity Details 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (12) C13; (2) C19
Output Nominal Voltage 120-240V
Overload Protection 16A circuit breaker
USER INTERFACE, ALERTS & CONTROLS
Switches No power switch
PHYSICAL
Material of Construction Metal
Form Factors Supported 1U rackmount, 0U vertical rackmount, wall-mount and undercounter installation supported
Minimum Required Rack Depth (inches) 7.8
Outlets Measurement (Center to Center) Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 2.10 x 20.60 x 9.30
Shipping Weight (lbs.) 3.70
Unit Dimensions (hwd / in.) 1.75 x 17.5 x 4.25
Unit Weight (lbs.) 3.20
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non-condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada), CE (Europe); NOM (Mexico); RETIE (Columbia)
Certification Details Series Number(s) AGIB24016RMPDU1
WARRANTY
Product Warranty Period (Worldwide) 5-year limited warranty

Overview

The PDU12IEC 1.9/3.8kW Single-Phase 120–240V Basic PDU is the perfect no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Perfectly suited for high-density IT environments, the PDU12IEC features a single load bank with 14 total outlets—eight rear C13, two rear C19 and four front C13. The C20 inlet accepts a variety of user-provided power cords that connect to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment.

The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 16A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing mounts in 1U of space in EIA-standard 19-inch racks, as well as on a wall or workbench or under a counter. With a compatible rack and Tripp Lite’s PDUSIDEBRKT accessory (sold separately), you can adapt the PDU12IEC for vertical 0U rack-mounting.

Features

Reliable Single-Phase Power Distribution
  • Ideal no-frills PDU for networking, telecom, security, audio/video and sound reinforcement applications
  • 14 total outlets—8 rear C13, 2 rear C19 and 4 front C13—in one load bank
  • Built-in 16A circuit breakers protect outlets against overloads
  • C20 inlet accepts wide variety of user-supplied power cords
  • Rear-panel grounding lug

Switchless Design
  • Prevents accidental shutdowns and costly downtime

Versatile Installation Options
  • Mounts horizontally in 1U of EIA-standard 19 in. 2- and 4-post racks
  • Reversible all-metal housing faces front or rear in rack
  • Ready for toolless 0U vertical installation with optional PDUSIDEBRKT (sold separately)
  • Also mounts on wall, workbench or under a counter

Package Includes

  • PDU12IEC 1.9/3.8kW Single-Phase 120–240V Basic PDU
  • Mounting hardware
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332116253
PDU Type Basic
INPUT
PDU Input Voltage 120; 125; 127; 200; 208; 220; 230; 240
Recommended Electrical Service Single-phase 16/20A 120-240V service
Maximum Input Amps 16
Maximum Input Amps Details Agency derated to 16A continuous (North America only)
PDU Plug Type IEC-320 C20
Input Phase Single-Phase
Input Cord Details C20 inlet accepts user supplied input cable with C19 output connection
Input Cord Length (ft.) 0
OUTPUT
Output Capacity Details 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (12) C13; (2) C19
Output Nominal Voltage 120-240V
Overload Protection 16A circuit breaker
USER INTERFACE, ALERTS & CONTROLS
Switches No power switch
PHYSICAL
Material of Construction Metal
Form Factors Supported 1U rackmount, 0U vertical rackmount, wall-mount and undercounter installation supported
Minimum Required Rack Depth (inches) 7.8
Outlets Measurement (Center to Center) Distance between Front (C13) outlets = 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear (C13) outelts = 28.75mm
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 2.10 x 20.60 x 9.30
Shipping Weight (lbs.) 3.70
Unit Dimensions (hwd / in.) 1.75 x 17.5 x 4.25
Unit Weight (lbs.) 3.20
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non-condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada), CE (Europe); NOM (Mexico); RETIE (Columbia)
Certification Details Series Number(s) AGIB24016RMPDU1
WARRANTY
Product Warranty Period (Worldwide) 5-year limited warranty