Product Overview
Overview
The PDUH32HV 7.7kW Single-Phase 200-240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUH32HV features 10 total outlets—two in front and eight in the rear. The IEC 309 32A Blue (2P+E) input plug with 3.6 m cord connects to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment.
The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 20A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA-standard 19-inch racks, under a counter or on a wall or workbench.
Features
- Ideal no-frills PDU for data centers, server rooms and network wiring closets
- 10 total C13 outlets—8 rear and 2 front
- IEC 309 32A Blue (2P+E) input with 3.6 m power cord
- Rear-panel grounding lug
- Dual 20A circuit breakers protect against overloads
Switchless Design
- Prevents accidental shutdowns and costly downtime
Versatile Installation Options
- Reversible all-metal housing faces front or rear in rack
- Supports 1U horizontal or 0U vertical mounting in EIA-standard 19 in. racks
- Also mounts on wall, workbench or under a counter
Specifications
OVERVIEW
| UPC Code | 037332183224 |
| PDU Type | Basic |
INPUT
| PDU Input Voltage | 200; 208; 220; 230; 240 |
| Recommended Electrical Service | Single-phase 32A 200-240V service |
| Maximum Input Amps | 32 |
| PDU Plug Type | IEC-309 32A BLUE (2P+E) |
| Input Phase | Single-Phase |
| Input Cord Length (ft.) | 12 |
OUTPUT
| Output Capacity Details | 7.7kW (240V), 7.4kW (230V), 7kW (220V), 6.7kW (208V), 6.4kW (200V) / 32A total capacity; 16A max per breakered outlet bank; 10A max per C13 outlet |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacles | (10) C13 |
| Output Nominal Voltage | 200-240V |
| Overload Protection | Two 20A circuit breakers protect 5 outlets each |
PHYSICAL
| Material of Construction | Metal |
| Form Factors Supported | 1U rackmount, 0U vertical mount, wallmount and under-counter |
| Minimum Required Rack Depth (inches) | 6 |
| PDU Form Factor | Horizontal (1U) |
| Shipping Dimensions (hwd / in.) | 3.00 x 20.25 x 11.25 |
| Shipping Weight (lbs.) | 7.07 |
| Unit Dimensions (hwd / in.) | 1.75 x 17.5 x 3.75 |
| Unit Weight (lbs.) | 6.32 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +50°C (-22°F to +122°F) |
| Relative Humidity | 5-95% non-condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
FEATURES & SPECIFICATIONS
| TVSS Grounding | Grounding lug |
STANDARDS & COMPLIANCE
| Certifications | Tested to CE (IEC62368-1:2014 2nd Ed, EAC (Russia), Class A, RoHS |
| Certification Details | Series Number(s) AG-00E5 |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |
Overview
The PDUH32HV 7.7kW Single-Phase 200-240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUH32HV features 10 total outlets—two in front and eight in the rear. The IEC 309 32A Blue (2P+E) input plug with 3.6 m cord connects to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment.
The switchless design prevents an accidental shutdown, which could lead to costly downtime. Dual 20A circuit breakers protect connected equipment from dangerous overloads. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA-standard 19-inch racks, under a counter or on a wall or workbench.
Features
- Ideal no-frills PDU for data centers, server rooms and network wiring closets
- 10 total C13 outlets—8 rear and 2 front
- IEC 309 32A Blue (2P+E) input with 3.6 m power cord
- Rear-panel grounding lug
- Dual 20A circuit breakers protect against overloads
Switchless Design
- Prevents accidental shutdowns and costly downtime
Versatile Installation Options
- Reversible all-metal housing faces front or rear in rack
- Supports 1U horizontal or 0U vertical mounting in EIA-standard 19 in. racks
- Also mounts on wall, workbench or under a counter
Specifications
OVERVIEW
| UPC Code | 037332183224 |
| PDU Type | Basic |
INPUT
| PDU Input Voltage | 200; 208; 220; 230; 240 |
| Recommended Electrical Service | Single-phase 32A 200-240V service |
| Maximum Input Amps | 32 |
| PDU Plug Type | IEC-309 32A BLUE (2P+E) |
| Input Phase | Single-Phase |
| Input Cord Length (ft.) | 12 |
OUTPUT
| Output Capacity Details | 7.7kW (240V), 7.4kW (230V), 7kW (220V), 6.7kW (208V), 6.4kW (200V) / 32A total capacity; 16A max per breakered outlet bank; 10A max per C13 outlet |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacles | (10) C13 |
| Output Nominal Voltage | 200-240V |
| Overload Protection | Two 20A circuit breakers protect 5 outlets each |
PHYSICAL
| Material of Construction | Metal |
| Form Factors Supported | 1U rackmount, 0U vertical mount, wallmount and under-counter |
| Minimum Required Rack Depth (inches) | 6 |
| PDU Form Factor | Horizontal (1U) |
| Shipping Dimensions (hwd / in.) | 3.00 x 20.25 x 11.25 |
| Shipping Weight (lbs.) | 7.07 |
| Unit Dimensions (hwd / in.) | 1.75 x 17.5 x 3.75 |
| Unit Weight (lbs.) | 6.32 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +50°C (-22°F to +122°F) |
| Relative Humidity | 5-95% non-condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
FEATURES & SPECIFICATIONS
| TVSS Grounding | Grounding lug |
STANDARDS & COMPLIANCE
| Certifications | Tested to CE (IEC62368-1:2014 2nd Ed, EAC (Russia), Class A, RoHS |
| Certification Details | Series Number(s) AG-00E5 |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |