Belden 9118 0101000 CATV Video, RG6, 18 AWG BCCS, Tri Shield, CM PVC Jacket
CATV, Series 6, 18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® III, aluminum braid shield (60% coverage), CM PVC jacket.
Ordering Details
- Manufacturer Part Number: 9118 0101000
- Color: Black
- Length: 1,000 ft
- Put-Up: Reel
- UPC/EAN: 612825224631
- Manufacturer Footnote: C Z
Supplied as one 1,000 ft Reel.
Construction Details
- RG Type: 6
- Series Type: 6
- Size: 18; Stranding: Solid; Nom. Diameter: 0.04 in; Material: BCCS - Bare Copper Covered Steel
- Material: PE - Polyethylene (Foam); Nom. Insulation Diameter: 0.18 in (4.6 mm)
- Insulation Table Notes: Gas Injected
- Layer: 1; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duofoil®; Coverage: 100%
- Layer: 2; Outer Shield Type: Braid; Material: Aluminum; Coverage: 60%
- Layer: 3; Outer Shield Type: Tape; Material: Tri-Laminate (Alum+Poly+Alum); Material Trade Name: Duofoil®; Coverage: 100%
- Material: PVC - Polyvinyl Chloride; Nom. Diameter: 0.275 in
Electrical Characteristics
- Frequency: 5-1000 MHz; Min. Structural Return Loss: 20 dB
- Max. Attenuation: 0.58 dB/100ft
- Max. Attenuation: 1.60 dB/100ft
- Max. Attenuation: 3.05 dB/100ft
- Max. Attenuation: 3.37 dB/100ft
- Max. Attenuation: 3.55 dB/100ft
- Max. Attenuation: 3.85 dB/100ft
- Max. Attenuation: 4.15 dB/100ft
- Max. Attenuation: 4.40 dB/100ft
- Max. Attenuation: 4.90 dB/100ft
- Max. Attenuation: 5.65 dB/100ft
- Max. Attenuation: 6.11 dB/100ft
- Max. Attenuation: 6.55 dB/100ft
- Nom. Conductor DCR: 28 Ohm/1000ft (92 Ohm/km); Nom. Outer Shield DCR: 6.5 Ohm/1000ft (21 Ohm/km); Nom. Capacitance Cond-to-Shield: 16.2 pF/ft (53.1 pF/m); Nom. Characteristic Impedance: 75 Ohm; Nom. Velocity of Prop.: 83%
- UL Voltage Rating: 350 V RMS
Mechanical Characteristics
- UL Temperature: 80°C; Operating: -40°C To +80°C
- Max. Pull Tension: 126 lbs (57.2 kg)
- Bulk Cable Weight: 27 lbs/1000ft (40 kg/km)
Standards and Compliance
- Environmental Suitability: Indoor (Not Riser or Plenum), Indoor
- Flammability / Reaction to Fire: UL1685 UL Loading, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: CATV, CM
- CEC / C(UL) Compliance: CM
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.429 Revision Date: 11-06-2026
- Footnote: C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.