Description
Belden 7895A T5U5000 DeviceBus®, 2 Pr #18+20 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, CMG, PLTC
DeviceBus® for ODVA DeviceNet™, 2 Pair 18+20AWG (19x30+19x32) Tinned Copper, PVC+Foam PE Insulation, Individual Beldfoil® & OA Tinned Copper Braid(65%) Shield, PVC Outer Jacket, CMG, PLTC
Ordering Details
- Manufacturer Part Number: 7895A T5U5000
- Color: Gray T5U
- Length: 5,000 ft
- Put-Up: Reel
- UPC/EAN: 612825190813
- Manufacturer Footnote: C Z
Supplied as one 5,000 ft Reel.
Product Overview
- Suitable Applications: harsh environment, ODVA device-level communication, used with CIP (common Industrial Protocol) for control, configuration, and data collection between devices, such as sensors and actuators, and higher level devices such as PLC, and PC in industrial automation, bus topology, etc.
Construction Details
- Element: Power Pair(s); No. of Elements: 1; Size: 18 AWG; Stranding: 19x30; Material: TC - Tinned Copper
- Element: Data Pair(s); No. of Elements: 1; Size: 20 AWG; Stranding: 19x32; Material: TC - Tinned Copper
- Element: Power Pair(s); Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.018 in (0.46 mm); Nom. Insulation Diameter: 0.080 in (2.0 mm); Color Code: Red & Black
- Element: Data Pair(s); Material: PE - Polyethylene (Foam); Nom. Thickness: 0.040 in (1.0 mm); Nom. Insulation Diameter: 0.129 in (3.28 mm); Color Code: Blue & White
- Element: Power Pair(s); Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%
- Element: Data Pair(s); Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%
- Shield Type: Braid; Material: Tinned Copper (TC); Coverage: 65%; Drainwire Type: 20 AWG (19x32) TC
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.045 in (1.1 mm); Nom. Diameter: 0.378 in (9.60 mm)
- Outer Jacket1 Table Notes: Jacket OD +/- 0.010
- Overall Cable Diameter (Nominal): 0.378 in (9.60 mm)
Electrical Characteristics
- Element: Power Pair(s); Nom. Conductor DCR: 6.9 Ohm/1000ft; Max. Conductor DCR: 6.9 Ohm/1000ft; Max. Current: 4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)
- Element: Data Pair(s); Nom. Conductor DCR: 10.9 Ohm/1000ft (35.8 Ohm/km); Max. Conductor DCR: 10.9 Ohm/100m; Nom. Capacitance Cond-to-Cond: 12 pF/ft (39 pF/m); Nom. Characteristic Impedence: 120 Ohm; Nom. Velocity of Prop.: 75%
- Nom Outer Shield DCR: 3.2 Ohm/1000ft (10 Ohm/km)
- UL Voltage Rating: 300 V (CMG, PLTC), 600 V (UL AWM 20201)
Mechanical Characteristics
- UL Temperature: 75°C; Operating: -20°C to +75°C
- Stationary Min.: 3.8 in (97 mm); Installation Min.: 3.8 in (97 mm)
- Max. Pull Tension: 65 lbs (29 kg)
- Bulk Cable Weight: 76 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance
- Flammability / Reaction to Fire: UL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Eca
- NEC / UL Compliance: Article 725, Article 800, CMG, PLTC
- AWM Compliance: AWM 20201
- CEC / C(UL) Compliance: CMG
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- UK Regulation Compliance: UKCA Mark
- Other Standard Compliance(s): ODVA Cable III
Product Notes
- Notes: Mid. Meter marks on jacket to aid users in installation. ODVA DeviceNet is an Open DeviceNet Vendor Association, Inc. trademark.
History
- Update and Revision: Revision Number: 0.551 Revision Date: 02-20-2026
- Footnote: C - CRATE REEL PUT-UP., Z - FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.