Specifications

  • Phases: 3
  • Nominal input voltage [V]: 3 x 400 … 500 VAC (connection without neutral conductor)
  • Input voltage range: 3 x 340 … 550 VAC
  • Nominal mains frequency range: 50 … 60 Hz
  • Input current Ii: ≤ 3 x 0.4 A (400 VAC; 24 VDC / 5 A)
  • Inrush current: ≤ 15 A (after 1 ms)
  • Power factor correction (PFC): Active
  • Mains failure hold-up time: ≥ 20 ms (3 x 400 VAC)
  • Nominal output voltage [V]: 24 VDC (SELV)
  • Output voltage range: DC 24 V
  • Default Setting: 24 VDC
  • Nominal output current Io nom: 5 A (24 VDC)
  • Nominal output power: 120 W
  • Deviation: ≤ 1 %
  • Residual ripple: ≤ 70 mV (peak-to-peak)
  • Current limitation: 1.1 x Io nom (typ.)
  • Overload behavior: TopBoost/PowerBoost/Time-limited constant current mode (other overload behaviors can be set)
  • PowerBoost: 7.5 ADC (5 s)
  • TopBoost: Up to 600 %
  • Signaling: Optical status indication (DC OK; load; warning and error states); Digital signal input and output (DI/DO)
  • Communications: EtherNet/IPTM (2789-9023 Communication Module); USB (750-923 Communication Cable); Ethernet/IP (2789-9023 Communication Module); IO-Link (2789-9080 Communication Module); Modbus RTU (Communication Module 2789-9015); Modbus TCP (2789-9052 Communication Module)
  • Efficiency (typ.): 92.5 % (230 VAC; 5 A; 25 °C)
  • Pre-fuse (required): An external DC fuse is required for the DC input voltage.
  • Backup fuse (recommended): 3 x 16 A (for USA/Canada: 3 x 15 A)
  • Isolation voltage (pri.-sec., AC): 3,510 V
  • Isolation voltage (pri.-PE, AC): 2,200 V
  • Isolation voltage (sec.-PE): 0.5 kVDC
  • Isolation voltage (sec.-signal): 0.5 kVDC
  • Protection class: I
  • protection rating: IP20; per EN 60529
  • Overvoltage category: III (≤ 2000 m a.s.l.); II (> 2000 m a.s.l.)
  • Pollution degree: 2
  • Transient suppression (primary): Yes
  • Overvoltage protection; secondary: Internal protective circuit; ≤ 35 VDC (in the event of a fault)
  • Short-circuit-protected: Yes
  • Open-circuit-proof: Yes
  • Parallel operation: Yes
  • Series operation: Yes
  • MTBF: > 1,400,000 h (per IEC 61709)
  • Connection 1 — Connection type: Input/signaling
  • Connection 1 — Connection technology: CAGE CLAMP®
  • Connection 1 — WAGO connector: WAGO 721 Series
  • Connection 1 — Solid conductor: 0.08 … 2.5 mm² / 28 … 12 AWG
  • Connection 1 — Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 12 AWG
  • Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.25 … 1.5 mm² / 20 … 16 AWG
  • Connection 1 — Fine-stranded conductor; with uninsulated ferrule: 0.25 … 2.5 mm² / 20 … 14 AWG
  • Connection 1 — Strip length: 8 … 9 mm / 0.31 … 0.35 inches
  • Connection 2 — Connection type: Output
  • Connection 2 — Connection technology: Push-in CAGE CLAMP®
  • Connection 2 — WAGO connector: WAGO 831 Series
  • Connection 2 — Solid conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 2 — Fine-stranded conductor: 0.5 … 10 mm² / 20 … 8 AWG
  • Connection 2 — Fine-stranded conductor; with insulated ferrule: 0.5 … 6 mm²
  • Connection 2 — Fine-stranded conductor; with uninsulated ferrule: 0.5 … 6 mm²
  • Connection 2 — Strip length: 13 … 15 mm / 0.51 … 0.59 inches
  • Width: 40 mm / 1.57 inches
  • Height: 130 mm / 5.118 inches
  • Depth from upper-edge of DIN-rail: 130 mm / 5.118 inches
  • Note (dimensions): Height without connector; Height with connector: 166 mm
  • Mounting type: DIN-35 rail
  • Weight: 650 g
  • Ambient temperature (operation): -25 … +70 °C (Device starts at -40 °C (type-tested))
  • Ambient temperature (storage): -40 … +85 °C
  • Relative humidity: 5 … 96 % (no condensation permissible)
  • Derating: See instruction leaflet
  • Climatic category: 3K3 (per EN 60721)
  • Operating altitude (max.): 5000 m
  • Conformity marking: CE
  • Standards/specifications: UL 121201 (HazLoc); EN 61010-2-201; EN 61204-3; UL 61010-1; UL 61010-2-201; SEMI F47