null

WAGO 2604-1103 PCB terminal block, Push-in CAGE CLAMP with operating lever, AWG 24 - 12, Pin spacing 5 mm, 3-pole, side entry, gray

$3.16
SKU:
2604-1103
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.


Manufacturer Information

Wago orders require a $100 combined minimum order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

The WAGO 2604-1103 pCB terminal block features Push-in CAGE CLAMP with operating lever, AWG 24 - 12, Pin spacing 5 mm, 3-pole, side entry, gray.

Specifications

  • IEC Approvals — Ratings per: IEC/EN 60664-1
  • IEC Approvals — Rated voltage (III / 3): 320 V
  • IEC Approvals — Rated impulse withstand voltage (III / 3): 4 kV
  • IEC Approvals — Rated voltage (III/2): 400 V
  • IEC Approvals — Rated impulse withstand voltage (III/2): 4 kV
  • IEC Approvals — Nominal voltage (II/2): 630 V
  • IEC Approvals — Rated impulse withstand voltage (II/2): 4 kV
  • IEC Approvals — Rated current: 32 A
  • IEC Approvals — Legend (ratings): (III / 2) ≙ Overvoltage category III / Pollution degree 2
  • UL Approvals — Approvals per: UL 1059
  • UL Approvals — Rated voltage UL (Use Group B): 300 V
  • UL Approvals — Rated current UL (Use Group B): 20 A
  • UL Approvals — Rated voltage UL (Use Group D): 300 V
  • UL Approvals — Rated current UL (Use Group D): 10 A
  • Approvals per: CSA
  • Rated voltage CSA (Use Group B): 300 V
  • Rated current CSA (Use Group B): 20 A
  • Rated voltage CSA (Use Group D): 300 V
  • Rated current CSA (Use Group D): 5 A
  • Connection Data — Clamping units: 3
  • Connection Data — Total number of potentials: 3
  • Connection Data — Number of connection types: 1
  • Connection Data — Number of levels: 1
  • Connection 1 — Connection technology: Push-in CAGE CLAMP®
  • Connection 1 — Actuation Method: Lever
  • Connection 1 — Solid conductor: 0.2 … 4 mm² / 24 … 12 AWG
  • Connection 1 — Fine-stranded conductor: 0.2 … 4 mm² / 24 … 12 AWG
  • Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.25 … 2.5 mm²
  • Connection 1 — Fine-stranded conductor; with uninsulated ferrule: 0.25 … 2.5 mm²
  • Connection 1 — Fine-stranded conductor; with twin ferrule: 0.25 … 1.5 mm²
  • Connection 1 — Strip length: 9 … 11 mm / 0.35 … 0.43 inches
  • Connection 1 — Conductor connection direction to PCB: 0 °
  • Connection 1 — Number of poles: 3
  • Pin spacing: 5 mm / 0.197 inches
  • Width: 17.4 mm / 0.685 inches
  • Height: 20.7 mm / 0.815 inches
  • Height from the surface: 16.7 mm / 0.657 inches
  • Depth: 19.2 mm / 0.756 inches
  • Solder pin length: 4 mm
  • Solder pin dimensions: 0.8 x 1 mm
  • Drilled hole diameter: 1.3 (+0.1) mm
  • PCB contact: THT
  • Solder pin arrangement: over the entire terminal strip (in-line)
  • Number of solder pins per potential: 2
  • Color: gray
  • Insulation material (main housing): Polyamide (PA66)
  • Flammability class per UL94: V0
  • Contact material: Electrolytic copper (ECu)
  • Actuator color: orange
  • Weight: 4.7 g
  • Limit temperature range: -60 … +105 °C
  • Ambient temperature (installation): -35 … +60 °C
  • Processing temperature: -35 … +60 °C
  • Continuous operating temperature: -60 … +105 °C
  • Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
  • Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
  • Spectrum/Mounting location: Service life test, Category 1, Class A/B
  • Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
  • Frequency: f1 = 5 Hz to f2 = 150 Hz
  • Acceleration: 0.101g (highest test level used for all axes)
  • Test duration per axis: 10 min.
  • Test directions: X, Y and Z axes
  • Monitoring of contact faults and interruptions: Passed
  • Voltage drop measurement before and after each axis: Passed
  • Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
  • Acceleration: 0.572g (highest test level used for all axes)
  • Test duration per axis: 5 h
  • Extended testing: Monitoring of contact faults and interruptions: Passed
  • Extended testing: Voltage drop measurement before and after each axis: Passed
  • Shock test: Test passed according to Section 10 of the standard
  • Shock pulse form: Half sine
  • Acceleration: 5g (highest test level used for all axes)
  • Shock duration: 30 ms
  • Number of shocks (per axis): 3 pos. und 3 neg.
  • Vibration and shock stress for rolling stock equipment: Passed

Installation: Supply with WAGO installation instructions and follow the manufacturer’s technical ratings and installation requirements.

Image shown is representative. Refer to the product specifications for the exact configuration.