null

Tripp-Lite PDUMNH16HVAT 3.8kW Single-Phase Monitored Automatic Transfer Switch PDU

$1,013.99
SKU:
PDUMNH16HVAT
Shipping:
Calculated at Checkout
Product Type:
Single Phase PDU

Product Overview

Overview

The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).

Features

Primary and Secondary Inputs for Power Redundancy
  • Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • IEC309 16A Blue (2P+E) inputs with 10-ft. (3.05 m) cords connect to separate primary and secondary single-phase power sources
  • Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
  • Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)
Automatic Transfer Switching
  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Switches to secondary power source if primary source fails or becomes unstable
  • 1-5 ms transfer time ensures uninterrupted operation of connected equipment
  • Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display with LEDs
  • Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
  • LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Real-time load/current data with billing-grade accuracy (+/- 1 percent)
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
Broad Communications Compatibility
  • HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
  • 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
  • Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
  • Optional PDU4PKIT rail kit (sold separately) adds rear mounting support

Package Includes

  • PDUMNH16HVAT 3.8kW Single-Phase 200-240V ATS/Monitored PDU
  • Rack-mounting brackets
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332186560
PDU Type Monitored; Auto-Transfer Switch
INPUT
PDU Input Voltage 200-240V
Recommended Electrical Service Two single-phase 16A 200-240V circuits
Maximum Input Amps 16
PDU Plug Type (2) IEC-309 16A BLUE (2P+E)
Input Phase Single-Phase
Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum
Frequency Compatibility 50 / 60 Hz
Output Receptacles (1) IEC309 16A BLUE (2P+E)
Output Nominal Voltage 200-240V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
Front Panel LEDs Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
Switches ENTER and MODE switches toggle the digital display to display all reported information
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported 1U rackmount
Minimum Required Rack Depth (inches) 17.5
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 7.20 x 20.50 x 21.10
Shipping Weight (lbs.) 16.70
Unit Dimensions (hwd / in.) 1.72 x 16.93 x 14
Unit Weight (lbs.) 17.36
ENVIRONMENTAL
Operating Temperature Range 0C ~ 50C (32F ~ 122F)
Storage Temperature Range -30°C to +60°C (-22°F to +140°F)
Relative Humidity 5 to 95% (non-condensing)
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to CE (IEC60950-1+A1,A2; Class A)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Overview

The PDUMNH16HVAT 3.8kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-ft. (3.05 m) input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with optional ENVIROSENSE2 module (sold separate).

Features

Primary and Secondary Inputs for Power Redundancy
  • Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
  • IEC309 16A Blue (2P+E) inputs with 10-ft. (3.05 m) cords connect to separate primary and secondary single-phase power sources
  • Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
  • Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input (sold separately)
Automatic Transfer Switching
  • Dynamic solid-state (TRIAC) automatic transfer switching
  • Switches to secondary power source if primary source fails or becomes unstable
  • 1-5 ms transfer time ensures uninterrupted operation of connected equipment
  • Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display with LEDs
  • Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
  • LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
  • Real-time load/current data with billing-grade accuracy (+/- 1 percent)
  • Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
Broad Communications Compatibility
  • HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
  • 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
  • Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
  • Optional PDU4PKIT rail kit (sold separately) adds rear mounting support

Package Includes

  • PDUMNH16HVAT 3.8kW Single-Phase 200-240V ATS/Monitored PDU
  • Rack-mounting brackets
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332186560
PDU Type Monitored; Auto-Transfer Switch
INPUT
PDU Input Voltage 200-240V
Recommended Electrical Service Two single-phase 16A 200-240V circuits
Maximum Input Amps 16
PDU Plug Type (2) IEC-309 16A BLUE (2P+E)
Input Phase Single-Phase
Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 3.8kW (240V); 3.7kW (230V); 3.5kW (220V); 3.3kW (208V); 3.2kW (200V); 16A maximum
Frequency Compatibility 50 / 60 Hz
Output Receptacles (1) IEC309 16A BLUE (2P+E)
Output Nominal Voltage 200-240V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor
Front Panel LEDs Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status
Switches ENTER and MODE switches toggle the digital display to display all reported information
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported 1U rackmount
Minimum Required Rack Depth (inches) 17.5
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 7.20 x 20.50 x 21.10
Shipping Weight (lbs.) 16.70
Unit Dimensions (hwd / in.) 1.72 x 16.93 x 14
Unit Weight (lbs.) 17.36
ENVIRONMENTAL
Operating Temperature Range 0C ~ 50C (32F ~ 122F)
Storage Temperature Range -30°C to +60°C (-22°F to +140°F)
Relative Humidity 5 to 95% (non-condensing)
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to CE (IEC60950-1+A1,A2; Class A)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty