null

Tripp-Lite PDUMH30ATNET 2.9kW Single-Phase Switched Automatic Transfer Switch PDU

$1,452.99
SKU:
PDUMH30ATNET
Shipping:
Calculated at Checkout
Product Type:
Single Phase PDU

Product Overview

Features

  • 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A)
  • ATS features provide redundant power for critical network equipment with a single input power cord
  • Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
  • Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional EnviroSense2 sensor
  • 25 switched outlets (24 5-15/20R & 1 L5-30R)
  • 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth
  • Set of two 10-ft. / (3.05 m) NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections
  • ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
  • Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs
  • ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
  • Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
  • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
  • Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
  • PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
  • IP-based Auto Probe detects lost connectivity and restores service autonomously
  • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
  • Front panel LEDs confirm power availability on both input lines
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Package Includes

  • ATS / Switched PDU with two L5-30P inputs
  • Installable 2U mounting brackets
  • Operating manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332157294
PDU Type Auto-Transfer Switch; Switched
INPUT
PDU Input Voltage 120V DUAL INPUT
Recommended Electrical Service Two single-phase 30A 120V circuits
Maximum Input Amps 24
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type (2) NEMA L5-30P
Input Phase Single-Phase
Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 2.88kW (120V) / 24A total capacity; 24A max per L5-30R outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (24) 5-15/20R; (1) L5-30R
Output Nominal Voltage 120V
Overload Protection Two 20A output breakers protect 12 5-15/20R outlets each
Customized Load Management Receptacles   25 individually controllable outlets
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports output amps in 4 separately metered loading segments (BANK 1: 5-20R outlets #1-12; BANK 2: 5-20R outlets #13-24; BANK 3: L5-30R outlet #25; BANK 4: Total PDU output), whole-PDU output kW load level, input voltage on primary and secondary lines and *temperature / *humidity data (*with optional EnviroSense2 sensor)
Front Panel LEDs 25 LEDs display power on/off status for each outlet, plus 2 LEDs for power status on Primary and Secondary input connection and 3 additional LEDs to label the displayed numeric value as Amps, kW or Voltage
Switches ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output, input voltage (primary, secondary) and *temperature / *humidity data (*with optional  ENVIROSENSE  sensor)
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported 2U rackmount
Minimum Required Rack Depth (inches) 16.9
PDU Form Factor Horizontal (2U)
Shipping Dimensions (hwd / in.) 7.70 x 16.70 x 19.70
Shipping Weight (lbs.) 19.50
Unit Dimensions (hwd / in.) 3.4 x 17.3 x 11.9
Unit Weight (lbs.) 15.30
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5 to 95% (non-condensing)
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
High Availability PDU Features   Auto Probe Monitoring and Reboot (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS Compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Features

  • 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A)
  • ATS features provide redundant power for critical network equipment with a single input power cord
  • Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
  • Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional EnviroSense2 sensor
  • 25 switched outlets (24 5-15/20R & 1 L5-30R)
  • 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth
  • Set of two 10-ft. / (3.05 m) NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections
  • ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
  • Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs
  • ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
  • Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
  • On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
  • Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
  • PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
  • IP-based Auto Probe detects lost connectivity and restores service autonomously
  • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
  • Front panel LEDs confirm power availability on both input lines
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Package Includes

  • ATS / Switched PDU with two L5-30P inputs
  • Installable 2U mounting brackets
  • Operating manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332157294
PDU Type Auto-Transfer Switch; Switched
INPUT
PDU Input Voltage 120V DUAL INPUT
Recommended Electrical Service Two single-phase 30A 120V circuits
Maximum Input Amps 24
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type (2) NEMA L5-30P
Input Phase Single-Phase
Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 2.88kW (120V) / 24A total capacity; 24A max per L5-30R outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (24) 5-15/20R; (1) L5-30R
Output Nominal Voltage 120V
Overload Protection Two 20A output breakers protect 12 5-15/20R outlets each
Customized Load Management Receptacles   25 individually controllable outlets
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports output amps in 4 separately metered loading segments (BANK 1: 5-20R outlets #1-12; BANK 2: 5-20R outlets #13-24; BANK 3: L5-30R outlet #25; BANK 4: Total PDU output), whole-PDU output kW load level, input voltage on primary and secondary lines and *temperature / *humidity data (*with optional EnviroSense2 sensor)
Front Panel LEDs 25 LEDs display power on/off status for each outlet, plus 2 LEDs for power status on Primary and Secondary input connection and 3 additional LEDs to label the displayed numeric value as Amps, kW or Voltage
Switches ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output, input voltage (primary, secondary) and *temperature / *humidity data (*with optional  ENVIROSENSE  sensor)
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported 2U rackmount
Minimum Required Rack Depth (inches) 16.9
PDU Form Factor Horizontal (2U)
Shipping Dimensions (hwd / in.) 7.70 x 16.70 x 19.70
Shipping Weight (lbs.) 19.50
Unit Dimensions (hwd / in.) 3.4 x 17.3 x 11.9
Unit Weight (lbs.) 15.30
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5 to 95% (non-condensing)
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
High Availability PDU Features   Auto Probe Monitoring and Reboot (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS Compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty