null

Tripp-Lite PDU1420T 2.4kW Single-Phase 120V Basic PDU

$268.99
SKU:
PDU1420T
Shipping:
Calculated at Checkout
Product Type:
Single Phase PDU

Product Overview

Overview

The PDU1420T 2.4kW Single-Phase 120V Basic PDU is the perfect no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Perfectly suited for high-density IT environments, the PDU1420T features a single breakered load bank with 14 NEMA 5-15/20R outlets. The NEMA L5-20P input plug with long 15-ft. (4.57 m) cord connects to your facility's compatible AC power source, generator or protected UPS to distribute power to connected equipment.

The switchless design prevents an accidental shutdown, which could lead to costly downtime. A 20A circuit breaker protects connected equipment from dangerous overloads. The 24-inch all-metal housing supports toolless 0U vertical mounting in EIA-standard 19-inch racks, as well as on a wall or workbench or under a counter with user-supplied hardware.

Features

Reliable Single-Phase Power Distribution
  • Ideal no-frills PDU for networking, telecom, security, audio/video and sound reinforcement applications
  • 14 NEMA 5-15/20R outlets in one breakered load bank
  • 20A circuit breaker protects outlets against overloads
  • NEMA L5-20P input plug with 15-ft. (4.57 m) cord
  • 24 in. all-metal housing
Switchless Design
  • Prevents accidental shutdowns and costly downtime
Versatile Installation Options
  • Supports toolless 0U vertical mounting in EIA-standard 19 in. racks
  • Also mounts on wall, workbench or under a counter with user-supplied hardware

Package Includes

  • PDU1420T 2.4kW Single-Phase 120V Basic PDU
  • Mounting hardware
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332122254
PDU Type Basic
INPUT
PDU Input Voltage 120V
Recommended Electrical Service Single-phase 20A 120V service
Maximum Input Amps 20
PDU Plug Type NEMA L5-20P
Input Phase Single-Phase
Input Cord Length (ft.) 15
OUTPUT
Output Capacity Details 2.4kW (120V) / 24A total capacity; 16A max per 5-15/20R outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (14) 5-15/20R
Output Nominal Voltage 120V
Overload Protection 20A circuit breaker
USER INTERFACE, ALERTS & CONTROLS
Switches No power switch
PHYSICAL
Material of Construction Metal
Form Factors Supported Vertical or horizontal mounting supported in wallmount applications, racks and a variety of other surface types
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / in.) 27.70 x 2.40 x 5.80
Shipping Weight (lbs.) 6.60
Unit Dimensions (hwd / in.) 1.75 x 24 x 2.25
Unit Weight (lbs.) 5.6
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5 to 95% non-condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada)
WARRANTY
Product Warranty Period (Worldwide) 5-year limited warranty

Overview

The PDU1420T 2.4kW Single-Phase 120V Basic PDU is the perfect no-frills unit for networking, telecom, security, audio/video and sound reinforcement applications. Perfectly suited for high-density IT environments, the PDU1420T features a single breakered load bank with 14 NEMA 5-15/20R outlets. The NEMA L5-20P input plug with long 15-ft. (4.57 m) cord connects to your facility's compatible AC power source, generator or protected UPS to distribute power to connected equipment.

The switchless design prevents an accidental shutdown, which could lead to costly downtime. A 20A circuit breaker protects connected equipment from dangerous overloads. The 24-inch all-metal housing supports toolless 0U vertical mounting in EIA-standard 19-inch racks, as well as on a wall or workbench or under a counter with user-supplied hardware.

Features

Reliable Single-Phase Power Distribution
  • Ideal no-frills PDU for networking, telecom, security, audio/video and sound reinforcement applications
  • 14 NEMA 5-15/20R outlets in one breakered load bank
  • 20A circuit breaker protects outlets against overloads
  • NEMA L5-20P input plug with 15-ft. (4.57 m) cord
  • 24 in. all-metal housing
Switchless Design
  • Prevents accidental shutdowns and costly downtime
Versatile Installation Options
  • Supports toolless 0U vertical mounting in EIA-standard 19 in. racks
  • Also mounts on wall, workbench or under a counter with user-supplied hardware

Package Includes

  • PDU1420T 2.4kW Single-Phase 120V Basic PDU
  • Mounting hardware
  • Owner’s manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332122254
PDU Type Basic
INPUT
PDU Input Voltage 120V
Recommended Electrical Service Single-phase 20A 120V service
Maximum Input Amps 20
PDU Plug Type NEMA L5-20P
Input Phase Single-Phase
Input Cord Length (ft.) 15
OUTPUT
Output Capacity Details 2.4kW (120V) / 24A total capacity; 16A max per 5-15/20R outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (14) 5-15/20R
Output Nominal Voltage 120V
Overload Protection 20A circuit breaker
USER INTERFACE, ALERTS & CONTROLS
Switches No power switch
PHYSICAL
Material of Construction Metal
Form Factors Supported Vertical or horizontal mounting supported in wallmount applications, racks and a variety of other surface types
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / in.) 27.70 x 2.40 x 5.80
Shipping Weight (lbs.) 6.60
Unit Dimensions (hwd / in.) 1.75 x 24 x 2.25
Unit Weight (lbs.) 5.6
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5 to 95% non-condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding   Grounding lug
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada)