null

SICK 1116569 MAX30N-72A10BM0060 Linear encoders, ± 0.1 mm, Male connector, M12 type S (20x20 mm), 4-pin, A-coded

$832.00
SKU:
1116569
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

SICK 1116569 MAX30N-72A10BM0060 Linear encoders.

Features

  • Items supplied: Accessories not included with delivery, please order separately.

Safety-related parameters

  • MTTFD (mean time to dangerous failure): 69 years (EN ISO 13849-1) 1)

1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature of the electronics 60 °C, frequency of use 8,760 h/a.

Every 2nd failure of an electronic component is considered hazardous.

Performance

  • Housing: Ø 30 mm (31f7 - IN Cylinder Mounting Ø31H8)
  • Model: Compact, radial cable routing
  • Pressure pipe: Ø7x1.0 mm
  • Pipe cap: Flat
  • Position (F.S.): 0 mm ... 60 mm 1)
  • Null zone: 21.5 mm
  • Damping zone: 30 mm
  • Resolution: ± 0.1 mm
  • Linearity: Min. ± 0.25 mm
  • Tolerance zero zone: ≤ ± 1 mm
  • Tolerance damping zone(F.S.): ≤ ± 1 mm
  • Temperature drift: Min. ± 0.25 mm 3)
  • Analog/current: 4 mA ... 20 mA
  • Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
  • Connector length: 200 mm
  • Ambient temperature (fluid): –30 °C ... +95 °C 4)
  • Operating temperature (electronics): –40 °C ... +105 °C 5)
  • Maximum air humidity: 90 % (No condensation)
  • Operating pressure PN: 320 bar
  • Supply voltage VS: 24 V DC (+8 V DC ... +32 V DC)
  • Switch-on time: < 250 ms
  • Switch-on current: 5.0 A / 50 μs
  • Measuring frequency (internal): 2 ms
  • Transmission rate (cycle time): Continuous analog signal

1) F.S. = Full Scale (Measuring range).

2) F.S., hydraulic oil at operating temperature.

3) Increase in oil temperature by 40 °C.

4) Due to the maximum permissible (fluid) temperature at the O-ring and the temperature-dependent signal quality of the position magnet.

5) Taking into account self-heating, generated through constant electrical operation with supply voltage.

Interfaces

  • Analog/current: 4 mA ... 20 mA

Electronics

  • Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
  • Supply voltage VS: 24 V DC (+8 V DC ... +32 V DC)
  • Residual ripple: < 1% S-S
  • Power consumption: ≤ 1.25 W
  • Current consumption: ≤ 50 mA
  • Switch-on current: 5.0 A / 50 μs
  • Load resistance: 100 Ω ≤ RL ≤ 500 Ω
  • Overvoltage protection: ≤ 36 V at all terminals (60 s)
  • Reverse polarity protection: ≤ 36 V (at all poles)
  • Short-circuit protection: VS – GND on housing
  • Dielectric strength: 500 V DC, 0 V DC at the housing (60 s)
  • Insulation resistance: Riso ≥ 10 MΩ

Mechanics

  • Housing: Ø 30 mm (31f7 - IN Cylinder Mounting Ø31H8)
  • Pressure pipe: Ø7x1.0 mm
  • Pipe cap: Flat
  • O-ring: Ø24.99 x 3.53 mm
  • Support ring: Ø31.0 x 25.8 x 1.4 mm
  • Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
  • M12 plug/flange: Type S, DM 20x20 mm - hole pattern 14 mm (EN 61076-2-101)
  • Strand, diameter: Ø 1.4 mm
  • Plug, M12: 200 mm
  • Housing: Stainless steel 1.4305 (AISI 303)
  • Pressure pipe: Stainless steel 1.4404, AISI 316L
  • M12 male connector: Glass fiber reinforced polyamide, nickel-/gold-plated brass contacts
  • M12 flange: Nickel-plated brass with O-ring (NBR)
  • O-ring: NBR 70
  • Support ring: PTFE
  • Strands: PVC

Ambient data

  • EMC: EU Directive 2014/30
  • Generic standards: EN 61000-6-3: 2007 / EN 61000-6-2: 2016
  • Agricultural and forestry machinery: EN ISO 14982: 2009
  • Construction machinery: EN 13309: 2010
  • Transient pulses: ISO 7637-2: 2004 1)
  • ESD (air and contact discharge): ISO 61000-4-2: 2009
  • Sine: 15 g (sinusoidal) / 55 … 2,000 Hz / 3 axes × 24 h (IEC 60068-2-6 Fc:2008)
  • Sine over noise: 13 g (r.m.s.) / 10 ... 2,000 Hz / 3 axes × 36 h (IEC 60068-2-80 Fi: 2006)
  • Broadband noise: 15 g (r.m.s.) / 10 ... 2,000 Hz / 3 axes × 48 h (IEC 60068-2-64 Fh: 2008) 4)
  • Drop test: 1 m height (IEC 60068-2-31 Ec:2008)
  • Single shock: 3 × 100 g / 11 ms half-sine, 3 axes (IEC 60068-2-27 Ea: 2010)
  • Continuous shock: 1,000 × 50 g / 11 ms half-sine, 3 axes (IEC 60068-2-29 Eb: 1993)
  • Operating pressure PN: 320 bar
  • Overload pressure Pmax = PN x 1.2: 380 bar
  • Test pressure Pstat = PN x 1.5: 480 bar 5)
  • Storage: –20 °C +65 °C 6)7)
  • Ambient temperature (fluid): –30 °C ... +95 °C 8)
  • Operating temperature (electronics): –40 °C ... +105 °C 9)
  • Maximum air humidity: 90 % (No condensation)
  • Temperature cycles: 100 cycles: –30 °C ... +95 °C; IEC 60068-2-14 Na: 2009
  • Temperature change: TK ≤ ± 0.01%*F.S./°C IEC 60068-2-14 Nb: 2009
  • Temperature shocks: IEC 60068-2-14 Nc: 2009
  • Salznebel: 240 h, 35 °C (IEC 60068-2-52 Kb: 2018)
  • Air humidity: 90 % (No condensation)
  • Housing: IP67 (EN 60529: 2014) 10)
  • M12 male connector: IP69K (ISO 20653: 2013) 11)

1) Transient pulses rated according to EN ISO 14982 / EN 13309.

2) Transient pulses on signal lines rated according to ISO 13766-1.

3) Starting profile, cranking, load dump pulses rated according to ISO 13766-1.

4) Resonance peaks excluded.

5) Test pressure and housing contact surface (ring surface) in the cylinder base must be observed. See operating instructions 8021472.

6) Caused by dry storage of the O-ring in uninstalled state (no coating with oil).

7) R. H. 55%.

8) Due to the maximum permissible (fluid) temperature at the O-ring and the temperature-dependent signal quality of the position magnet.

9) Taking into account self-heating, generated through constant electrical operation with supply voltage.

10) When not connected.

11) When mated with a suitable M12 mating connector.

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • ACMA declaration of conformity: ✔
  • Moroccan declaration of conformity: ✔
  • China RoHS: ✔
  • Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔

Image is representative and may differ from the supplied item.