Description
SICK 1116827 MAX30N-72V10AC0200 Linear encoders.
Features
- Items supplied: Accessories not included with delivery, please order separately.
Safety-related parameters
- MTTFD (mean time to dangerous failure): 69 years (EN ISO 13849-1) 1)
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature of the electronics 60 °C, frequency of use 8,760 h/a.
Every 2nd failure of an electronic component is considered hazardous.
Performance
- Housing: Ø 30 mm (31f7 - IN Cylinder Mounting Ø31H8)
- Model: Compact, radial cable routing
- Pressure pipe: Ø7x1.0 mm
- Pipe cap: Flat
- Position (F.S.): 0 mm ... 200 mm 1)
- Null zone: 21.5 mm
- Damping zone: 30 mm
- Resolution: ± 0.1 mm
- Linearity: Min. ± 0.25 mm
- Tolerance zero zone: ≤ ± 1 mm
- Tolerance damping zone(F.S.): ≤ ± 1 mm
- Temperature drift: Min. ± 0.25 mm 3)
- Analog/voltage: 0.5 V DC ... 4.5 V DC
- Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
- Connector length: 80 mm
- Ambient temperature (fluid): –30 °C ... +95 °C 4)
- Operating temperature (electronics): –40 °C ... +105 °C 5)
- Maximum air humidity: 90 % (No condensation)
- Operating pressure PN: 320 bar
- Supply voltage VS: 24 V DC (+8 V DC ... +32 V DC)
- Switch-on time: < 250 ms
- Switch-on current: 5.0 A / 50 μs
- Measuring frequency (internal): 2 ms
- Transmission rate (cycle time): Continuous analog signal
1) F.S. = Full Scale (Measuring range).
2) F.S., hydraulic oil at operating temperature.
3) Increase in oil temperature by 40 °C.
4) Due to the maximum permissible (fluid) temperature at the O-ring and the temperature-dependent signal quality of the position magnet.
5) Taking into account self-heating, generated through constant electrical operation with supply voltage.
Interfaces
- Analog/voltage: 0.5 V DC ... 4.5 V DC
Electronics
- Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
- Supply voltage VS: 24 V DC (+8 V DC ... +32 V DC)
- Residual ripple: < 1% S-S
- Power consumption: ≤ 1.25 W
- Current consumption: ≤ 50 mA
- Switch-on current: 5.0 A / 50 μs
- Load resistance: RL ≥ 10 kΩ
- Overvoltage protection: ≤ 36 V at all terminals (60 s)
- Reverse polarity protection: ≤ 36 V (at all poles)
- Short-circuit protection: VS – GND on housing
- Dielectric strength: 500 V DC, 0 V DC at the housing (60 s)
- Insulation resistance: Riso ≥ 10 MΩ
Mechanics
- Housing: Ø 30 mm (31f7 - IN Cylinder Mounting Ø31H8)
- Pressure pipe: Ø7x1.0 mm
- Pipe cap: Flat
- O-ring: Ø24.99 x 3.53 mm
- Support ring: Ø31.0 x 25.8 x 1.4 mm
- Connection type: Male connector, M12 type S (20x20 mm), 4-pin, A-coded
- M12 plug/flange: Type S, DM 20x20 mm - hole pattern 14 mm (EN 61076-2-101)
- Strand, diameter: Ø 1.4 mm
- Plug, M12: 80 mm
- Housing: Stainless steel 1.4305 (AISI 303)
- Pressure pipe: Stainless steel 1.4404, AISI 316L
- M12 male connector: Glass fiber reinforced polyamide, nickel-/gold-plated brass contacts
- M12 flange: Nickel-plated brass with O-ring (NBR)
- O-ring: NBR 70
- Support ring: PTFE
- Strands: PVC
Ambient data
- EMC: EU Directive 2014/30
- Generic standards: EN 61000-6-3: 2007 / EN 61000-6-2: 2016
- Agricultural and forestry machinery: EN ISO 14982: 2009
- Construction machinery: EN 13309: 2010
- Transient pulses: ISO 7637-2: 2004 1)
- ESD (air and contact discharge): ISO 61000-4-2: 2009
- Sine: 15 g (sinusoidal) / 55 … 2,000 Hz / 3 axes × 24 h (IEC 60068-2-6 Fc:2008)
- Sine over noise: 13 g (r.m.s.) / 10 ... 2,000 Hz / 3 axes × 36 h (IEC 60068-2-80 Fi: 2006)
- Broadband noise: 15 g (r.m.s.) / 10 ... 2,000 Hz / 3 axes × 48 h (IEC 60068-2-64 Fh: 2008) 4)
- Drop test: 1 m height (IEC 60068-2-31 Ec:2008)
- Single shock: 3 × 100 g / 11 ms half-sine, 3 axes (IEC 60068-2-27 Ea: 2010)
- Continuous shock: 1,000 × 50 g / 11 ms half-sine, 3 axes (IEC 60068-2-29 Eb: 1993)
- Operating pressure PN: 320 bar
- Overload pressure Pmax = PN x 1.2: 380 bar
- Test pressure Pstat = PN x 1.5: 480 bar 5)
- Storage: –20 °C +65 °C 6)7)
- Ambient temperature (fluid): –30 °C ... +95 °C 8)
- Operating temperature (electronics): –40 °C ... +105 °C 9)
- Maximum air humidity: 90 % (No condensation)
- Temperature cycles: 100 cycles: –30 °C ... +95 °C; IEC 60068-2-14 Na: 2009
- Temperature change: TK ≤ ± 0.01%*F.S./°C IEC 60068-2-14 Nb: 2009
- Temperature shocks: IEC 60068-2-14 Nc: 2009
- Salznebel: 240 h, 35 °C (IEC 60068-2-52 Kb: 2018)
- Air humidity: 90 % (No condensation)
- Housing: IP67 (EN 60529: 2014) 10)
- M12 male connector: IP69K (ISO 20653: 2013) 11)
1) Transient pulses rated according to EN ISO 14982 / EN 13309.
2) Transient pulses on signal lines rated according to ISO 13766-1.
3) Starting profile, cranking, load dump pulses rated according to ISO 13766-1.
4) Resonance peaks excluded.
5) Test pressure and housing contact surface (ring surface) in the cylinder base must be observed. See operating instructions 8021472.
6) Caused by dry storage of the O-ring in uninstalled state (no coating with oil).
7) R. H. 55%.
8) Due to the maximum permissible (fluid) temperature at the O-ring and the temperature-dependent signal quality of the position magnet.
9) Taking into account self-heating, generated through constant electrical operation with supply voltage.
10) When not connected.
11) When mated with a suitable M12 mating connector.
Certificates
- EU declaration of conformity: ✔
- UK declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- Moroccan declaration of conformity: ✔
- China RoHS: ✔
- Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔