Description
SICK 1059464 MPA-503THTP0 Cylinder sensors.
Features
- Cylinder type: Universal
- Cylinder types with adapter: Round body cylinder; Tie rod cylinder; T-slot cylinders; Festo cylinders DSBC; SMC cylinders CP96
- Measuring range: 503 mm 1)
- Housing length: 505 mm
- Output function: Analog, IO-Link
- Electrical wiring: DC 4-wire
- Analog output (voltage): 0 V ... 10 V
- Analog output (current): 4 mA ... 20 mA 2)
- Enclosure rating: IP65 3); IP67; IP68
- Teach-in control panel: Teaching in the measuring range; Selecting the current/voltage output or IO-Link; Resetting the measuring range to factory settings
- IO-Link: Teaching in the measuring range; Resetting the measuring range
- IO-Link functions: Standard functions
1) ± 1 mm.
2) Default setting: Current output active.
3) According to EN 60529.
Mechanics/electronics
- Supply voltage: 15 V DC ... 30 V DC
- Power consumption: 35 mA, without load
- Max. load resistance: ≤ 500 Ω Power Output, at 24 V
- Min. load resistance: ≥ 2 kΩ 1)
- Protection class: III
- Required magnetic field sensitivity, typ.: 2 mT ... 15 mT
- Resolution, typ.: 0.03 % FSR (max. ≥ 0.06 mm) 2); 3)
- Linearity error, typ.: 0.5 mm 4)
- Repeat accuracy, typ.: 0.06 % FSR (≥ 0.1 mm) 5)
- Sampling rate, typ.: 1.15 ms 6)
- Reverse polarity protection: Yes
- Short-circuit protection: Yes
- Status indicator LED: Yes
- Teach-in: Yes
- Ambient operating temperature: –20 °C ... +70 °C
- Shock and vibration resistance: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm
- EMC: According to EN 60947-5-2 7)
- Connection type: Cable with M8 male connector, 4-pin, 0.3 m
- Deep-freeze property: Do not bend below 0 °C
- Conductor cross section: 0.08 mm²
- Cable diameter: Ø 2.6 mm
- Bending radius: With fixed installation > 5 x cable diameter
- Cable outlet: Axial
- Housing: Metal, Aluminum
- Cable: PUR
- UL File No.: NRKH.E181493 & NRKH7.E181493
1) Voltage output.
2) FSR: Full Scale Range; max. measuring range.
3) When using IO-Link, the resolution is 0.25 mm.
4) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.
5) At 25 ° C, repeatability magnet movement in one direction.
6) Only in standard mode, not in IO-Link mode.
7) The analog measured value can deviate under transient conditions.
Safety-related parameters
- MTTFD: 128 years
- DCavg: 0 %
- TM (mission time): 20 years
Communication interface
- Communication interface: IO-Link V1.0.1
- Communication Interface detail: COM2
- Cycle time: 2.3 ms
- Process data length: 16 Bit
- Process data structure: Bit 0 ... 3 = reserved; Bit 4 ... 5 = position (after decimal point); Bit 6 ... 15 = position (before decimal point)
Certificates
- EU declaration of conformity: ✔
- UK declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- Moroccan declaration of conformity: ✔
- China RoHS: ✔
- China Compulsory Product Certification (CCC) exempt: ✔
- cULus certificate: ✔
- IO-Link certificate: ✔