null
Happy Thanksgiving! We’ll be closed and

SICK 1059456 MPA-359THTP0 Cylinder sensors, 359 mm, Cable with M8 male connector, 4-pin, 0.3 m, PUR, 15 V DC ... 30 V DC

$832.00
SKU:
1059456
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

SICK 1059456 MPA-359THTP0 Cylinder sensors.

Features

  • Cylinder type: Universal
  • Cylinder types with adapter: Round body cylinder; Tie rod cylinder; T-slot cylinders; Festo cylinders DSBC; SMC cylinders CP96
  • Measuring range: 359 mm 1)
  • Housing length: 361 mm
  • Output function: Analog, IO-Link
  • Electrical wiring: DC 4-wire
  • Analog output (voltage): 0 V ... 10 V
  • Analog output (current): 4 mA ... 20 mA 2)
  • Enclosure rating: IP65 3); IP67; IP68
  • Teach-in control panel: Teaching in the measuring range; Selecting the current/voltage output or IO-Link; Resetting the measuring range to factory settings
  • IO-Link: Teaching in the measuring range; Resetting the measuring range
  • IO-Link functions: Standard functions

1) ± 1 mm.

2) Default setting: Current output active.

3) According to EN 60529.

Mechanics/electronics

  • Supply voltage: 15 V DC ... 30 V DC
  • Power consumption: 35 mA, without load
  • Max. load resistance: ≤ 500 Ω Power Output, at 24 V
  • Min. load resistance: ≥ 2 kΩ 1)
  • Protection class: III
  • Required magnetic field sensitivity, typ.: 2 mT ... 15 mT
  • Resolution, typ.: 0.03 % FSR (max. ≥ 0.06 mm) 2); 3)
  • Linearity error, typ.: 0.5 mm 4)
  • Repeat accuracy, typ.: 0.06 % FSR (≥ 0.1 mm) 5)
  • Sampling rate, typ.: 1.15 ms 6)
  • Reverse polarity protection: Yes
  • Short-circuit protection: Yes
  • Status indicator LED: Yes
  • Teach-in: Yes
  • Ambient operating temperature: –20 °C ... +70 °C
  • Shock and vibration resistance: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm
  • EMC: According to EN 60947-5-2 7)
  • Connection type: Cable with M8 male connector, 4-pin, 0.3 m
  • Deep-freeze property: Do not bend below 0 °C
  • Conductor cross section: 0.08 mm²
  • Cable diameter: Ø 2.6 mm
  • Bending radius: With fixed installation > 5 x cable diameter
  • Cable outlet: Axial
  • Housing: Metal, Aluminum
  • Cable: PUR
  • UL File No.: NRKH.E181493 & NRKH7.E181493

1) Voltage output.

2) FSR: Full Scale Range; max. measuring range.

3) When using IO-Link, the resolution is 0.25 mm.

4) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.

5) At 25 ° C, repeatability magnet movement in one direction.

6) Only in standard mode, not in IO-Link mode.

7) The analog measured value can deviate under transient conditions.

Safety-related parameters

  • MTTFD: 154 years
  • DCavg: 0 %
  • TM (mission time): 20 years

Communication interface

  • Communication interface: IO-Link V1.0.1
  • Communication Interface detail: COM2
  • Cycle time: 2.3 ms
  • Process data length: 16 Bit
  • Process data structure: Bit 0 ... 3 = reserved; Bit 4 ... 5 = position (after decimal point); Bit 6 ... 15 = position (before decimal point)

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • ACMA declaration of conformity: ✔
  • Moroccan declaration of conformity: ✔
  • China RoHS: ✔
  • China Compulsory Product Certification (CCC) exempt: ✔
  • cULus certificate: ✔
  • IO-Link certificate: ✔
  • Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔

Download SICK product specification sheet (PDF)