Description of Function

With input voltage applied, normal temperature condition (thermal switch closed) and no seal leakage, the over temperature relay is energized and the seal leak relay is de-energized. Both LEDs, are green, indicating normal conditions and input voltage is applied. When the motor temperature rises and the N.C. thermal switch opens, the over temperature relay is de-energized, open a contact that had been closed and turning off the pump contactor. The TEMP LED turns red. If the over temperature condition is cleared, the unit will reset based on the setting of the Over Temp switch. In the AUTO mode, the unit will reset automatically. In the MANUAL mode, the Over Temp Reset button must be pushed to clear the alarm and reset the relay. If the seal starts to leak, contaminating fluid enters the pump motor cavity. This lowers the resistance between the internal probe and the common connection. When the resistance drops below the user-adjustable sensitivity set-point of the relay, the output relay energizes and closes a contact, which can be used to give an alarm indication of a leaking seal. The LEAK LED turns red.

Features

  • Monitors submersible pump seals for Over Temperature & Seal Leakage
  • Works with pumps using resistance sensing leakage detection
  • Auto & Manual reset for over temperature
  • Flange enclosure for door-mounting
  • Two adjustable sensitivity ranges
  • Low profile adjustment knob
  • Full status indication on top of unit for easy troubleshooting
  • 11 pin back-mounted socket provided with relay

Specifications

  • Function configuration: Single Channel Seal Leak / Over Temperature
  • Control voltage: 24V AC/DC
  • Output: (2) 7A SPDT
  • Mount: 11-Pin Socket
  • Setting Adjustment: Analog
  • Enclosure Style: Flange
  • Configuration / Contact Rating: SPDT / SPNO 7A @ 240V AC / 7A @ 28V DC 1/4 HP @ 120V AC (N.O.)
  • Approvals: UL Recognized for the U.S. and Canada
  • AC Operation: +10/-15% of nominal at 50/60 Hz
  • DC Operation: +10/-15% of nominal
  • Load (Burden): 3 VA
  • Temp & Leakage Voltage: 5V DC Pulsed
  • Resistance Setting (Over Temperature): 5KΩ
  • Pick-up: 1 Second
  • Drop-out: 1 Second
  • Temperature: Operating: -28° to 65° C (-18° to 149° F)
  • Temperature: Storage: -40° to 85° C (-40° to 185° F)
  • Life: Mechanical: 10,000,000 operations
  • Life: Full Load: 100,000 operations
  • Mounting: Requires industry-standard 11 pin octal socket (Macromatic 70170-D or equivalent)