null

Altronix MAXIMAL75E Power Supply Charger

$839.83
SKU:
MAXIMAL75E
Shipping:
Calculated at Checkout

Product Overview

Power Supply/Charger, Expandable, 1 P/S 24VDC @ 10A & 1 P/S 12VDC @ 10A, 115VAC, BC800 Enclosure

Maximal75E provides system designers and installers with "maximum" power choices and the highest levels of versatility. It provides 12VDC and 24VDC via two (2) single output power supply/chargers. It includes AC fail, low battery and battery presence monitoring. Optional Altronix® field installable sub-assemblies provide multiple outputs and a wide range of features for specific Access Control and Fire Alarm applications.

Input
115VAC 60Hz, 7.0A input.

Output
12VDC and 24VDC output.
Maximum output current Options:
A) 24VDC @ 10A plus 12VDC @ 10A.
Filtered and electronically regulated outputs (built-in power supply).
Thermal and short circuit protection with auto reset.

Fuse Ratings
Power Supply input fuse ratings:
AL1012ULXB: 3.5A/250V
AL1024ULXB: 10A/250V

Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).

Visual Indicators
AC input and DC output LED indicators.

Electrical
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage - 20ºC to 70ºC ( - 4ºF to 158ºF).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 184 BTU/Hr.
System AC input VA requirement: 805VA.

Power Supply/Charger, Expandable, 1 P/S 24VDC @ 10A & 1 P/S 12VDC @ 10A, 115VAC, BC800 Enclosure

Maximal75E provides system designers and installers with "maximum" power choices and the highest levels of versatility. It provides 12VDC and 24VDC via two (2) single output power supply/chargers. It includes AC fail, low battery and battery presence monitoring. Optional Altronix® field installable sub-assemblies provide multiple outputs and a wide range of features for specific Access Control and Fire Alarm applications.

Input
115VAC 60Hz, 7.0A input.

Output
12VDC and 24VDC output.
Maximum output current Options:
A) 24VDC @ 10A plus 12VDC @ 10A.
Filtered and electronically regulated outputs (built-in power supply).
Thermal and short circuit protection with auto reset.

Fuse Ratings
Power Supply input fuse ratings:
AL1012ULXB: 3.5A/250V
AL1024ULXB: 10A/250V

Supervision
AC fail supervision (form "C" contacts).
Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
Low battery and battery presence supervision (form "C" contact).

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Zero voltage drop when unit switches over to battery backup (AC failure condition).

Visual Indicators
AC input and DC output LED indicators.

Electrical
Operating 0ºC to 49ºC (32ºF to 120ºF).
Storage - 20ºC to 70ºC ( - 4ºF to 158ºF).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 184 BTU/Hr.
System AC input VA requirement: 805VA.