Altronix FIRESWITCH108 NAC Power Supply

$701.99
SKU:
FIRESWITCH108
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

DESCRIPTION

NAC Power Supply, 4 Class A, 8 Class B, 24VDC @ 10A, LCD and Network Connection for Programming and Status Monitoring, 115VAC, Red BC400 Enclosure

The Altronix FireSwitch108 is a cost-effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP) to provide Notification Appliance Circuit expansion support, for additional horns/strobes to allow ADA compliancy. It also provides auxiliary power to support system accessories. It delivers electronically regulated and filtered 24VDC power to Class B or Class ANAC loop circuits. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5A max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode (output will follow input. i.e. March Time Input, March Time Output). In non-alarm condition independent loop supervision for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble, the FACP will be notified via the steered input (Input 1 or Input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop/ system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring.

FEATURES

  • Programmable LCD display interface.
  • EOL resistor value is programmable by output.
  • Ethernet port interface for remote programmability and monitoring.
  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter, Gentex®, System Sensor® , and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision directed to input 1 or input 2.
  • Common trouble Dry N.C. output for reporting trouble to remote FACP.
  • Ground fault detection - Ground fault maximum test impedance 1,000 Ohm.
  • Ground fault Dry N.O. output to report ground fault to remote FACP.
  • CO Temporal Code 4 (NFPA720) include Gentex® , Potter and System Sensor® devices.