null

Altronix AL1002ADA220 NAC Power Supply

$513.03
SKU:
AL1002ADA220
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

NAC Power Supply, 2 Class A or 4 Class B Outputs, 24VDC @ 10A, 220VAC, Red BC400 Enclosure

AL1002ADA220 are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.

Input
Nominal 220VAC (operating range 198VAC - 256VAC), 50/60 Hz, 2.5A.
Two (2) Class A, Style Z or two (2) Class B, Style W, Y FACP inputs.
Two (2) NC dry contact trigger inputs.

Output
24VDC @ 10A max total alarm current.
2.5A max current per output.
Separate 1.0A auxiliary output.
Programmable supervised indicating circuit outputs:
Four (4) Class B, Style W, Y or Two (2) Class A, Style Z or One (1) Class A, Style Z and Two (2) Class B, Style W, Y.
Thermal and short circuit protection with auto reset.

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switchover to stand-by battery when AC Fails.
Zero voltage drop when switching over to battery backup.

Supervision
AC fail supervision (form "C" contact, 1A/28VDC).
Factory set for 30 seconds with optional 2.5 to 3 hour delay setting (field selectable).
Instant local AC trouble reporting relay (form "C" contact, 1A/28VDC).
Battery presence and low battery supervision (form "C" contact, 1A/28VDC).

Visual Indicators
Input and output status LED indicators.

Special Features
2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
Compatible with 12VDC or 24VDC fire panels.
Output loop supervision steered to input 1 or input 2.
Signal circuit trouble memory (helps identify intermittent loop problems).
Common trouble input and output.
Ground fault detection.
Unit includes power supply, red enclosure, cam lock, and battery leads.

Temperature
Operating 0° C to 49° C (32° F to 120° F).
Storage - 20° C to 70° C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr. (approx.): 31 BTU/Hr.