Description

NAC Power Supply, 4 Class A or 4 Class B Outputs, 24VDC @ 10A, 220VAC, Red BC600 Enclosure

Altronix AL1042ADA220 is an extremely cost effective voltage regulated remote NAC Power Extender. It may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.

Input
Power input 220VAC (working range 198VAC - 256VAC), 50/60 Hz, 2.2A.
Two (2) Class A, Style Z or two (2) Class B, Style W, Y FACP inputs.
Two (2) NC dry contact trigger inputs.

Output
Class 2 Rated power limited outputs.
24VDC voltage regulated power limited outputs.
10A max total alarm current.
2.5A max current per output.
Two auxiliary outputs rated at 1A each (1A continuous, 1A AC disconnect).
Programmable supervised indicating circuit outputs:
Four (4) Class B, Style W, Y or Four (4) Class A, Style Z or Two (2) Class A, Style Z and Two (2) Class B, Style W, Y.
Thermal and short circuit protection with auto reset.

Battery Backup
Built-in charger for sealed lead acid or gel type batteries.
Automatic switchover to stand-by battery when AC fails.
Zero voltage drop when switching over to battery backup.
Supervision
AC fail supervision (form "C" contact, 1A / 28VDC).
Factory set for 30 seconds with optional 2.5 to 3 hour delay setting (field selectable).
Instant local AC trouble reporting relay (form "C" contact, 1A / 28VDC).
Battery presence and low battery supervision (form "C" contact, 1A / 28VDC).

Visual Indicators
Input and output status LED indicators.

Special Features
2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
Sync protocols include Potter/Amseco, Faraday, Gentex°, System Sensor°, and CooperWheelock°.
Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
Compatible with 12VDC or 24VDC fire panels.
Output loop supervision directed to input 1 or input 2.
Signal Circuit Trouble Memory - facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LEDs indicate/ identify which output the fault has occurred.
Common trouble input and output.
Ground fault detection.

Added Features
Unit includes power supply, logic board enclosure, cam lock, and battery leads.

Temperature
Operating 0° C to 49° C (32° F to 120° F).
Storage - 20° C to 70°C ( - 4° F to 158° F).
Relative Humidity 85% +/- 5%.
BTU/Hr (approx.): 31 BTU/Hr.