The WAGO 750-8217 controller PFC200 features 2nd Generation, 2 x ETHERNET, RS-232/-485, Mobile Radio Module 4G, EU version.

Specifications

  • Communications: Modbus (TCP, UDP); ETHERNET; EtherNet/IPTM Adapter (slave), library for _e!_ _RUNTIME_; Modbus RTU; RS-232 serial interface; RS-485 interface; MQTT; BACnet/IP, requires an additional license; EtherCAT® Master ( requires an additional license); Telecontrol protocols, requires an additional license
  • ETHERNET protocols: DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSH
  • Telecontrol protocols: IEC 60870 (additional license as slave or master); IEC 61850 (additional license as Client or Server); DNP3 (additional license as Slave or Master)
  • Visualization: Web-Visu
  • Operating system: Real-time Linux (with PREEMPT_RT patch)
  • CPU: Cortex A8; 1 GHz
  • Programming languages per IEC 61131-3: Instruction List (IL); Ladder Diagram (LD); Function Block Diagram (FBD); Continuous Function Chart (CFC); Structured Text (ST); Sequential Function Chart (SFC)
  • Programming environment: CODESYS V3.5; _e!_ _COCKPIT_ (based on CODESYS V3)
  • Configuration options: CODESYS V3; CODESYS Library; _e!_ _COCKPIT_; WAGO-I/O- _CHECK_; Web-Based Management; _e!_ _RUNTIME_ library; CODESYS Library
  • Security encryption: OpenVPN, IPsec, firewall
  • Services: SMS (bidirectional); GPRS connection to Internet
  • Radio technology: GSM/UMTS/LTE
  • Frequency band: GSM dual band (B3; B8); E-UTRA bands (B1; B3; B5; B7; B8; B20; B38; B40; B41)
  • Transmission rate: ETHERNET: 10/100 Mbit/s
  • Transmission medium (communication/fieldbus): ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
  • Main memory (RAM): 512MB
  • Internal memory (flash): 4096MB
  • Non-volatile hardware memory: 128kbyte
  • Program memory: 32 MB
  • Data memory: 128 MB
  • Non-volatile software memory: 128.kbyte
  • Type of memory card: SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO's memory card)
  • Memory Card Slot: Push-push mechanism; Cover lid (sealable)
  • SIM card type: Mini-SIM; Temperature range: −20 … +85 °C
  • SIM card slot: Push-push mechanism
  • Number of modules per node (max.): 250
  • Number of modules without a bus extension (max.): 64
  • Input and output process image (internal) max.: 1000 words/1000 words
  • Input and output process image (Modbus®) max.: CODESYS V3: 32000 words/32000 words
  • Drift – system clock (25 °C): 20ppm
  • Drift – Real Time Clock (25 °C): 3ppm
  • RTC backup time (25 °C): 30Tage
  • Indicators: LED (SYS, RUN, I/O, MS, NS, USR, S1 … S4, WDS, NET) red/green/orange: system status, program, local data bus, status programmable by user (can be used via CODESYS library), signal strength S1 … S4, data service status; LED (CON, A, B) green: mobile network status, system power supply status, field supply status
  • Supply voltage (system): 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP® connection); External fuse required: 2 A slow-blow
  • Input current (typ.) at nominal load (24 V): 550mA
  • Total current (system supply): 700mA
  • Supply voltage (field): 24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP® connection; distribution via spring contact); External fuse required: 10 A slow-blow
  • Current carrying capacity (power jumper contacts): 10A
  • Number of outgoing power jumper contacts: 3
  • Isolation: 500 V system/field
  • Connection Data — Connection technology: communication/fieldbus: Modbus (TCP, UDP): 2 x RJ-45; Modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-485 interface: 1 x D-sub 9 socket
  • Connection Data — Connection technology: system supply: 2 x CAGE CLAMP®
  • Connection Data — Connection technology: field supply: 6 x CAGE CLAMP®
  • Connection Data — Connectable conductor materials: Copper
  • Connection Data — Connection type: System/field supply
  • Connection Data — Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Connection Data — Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Connection Data — Strip length: 8 … 9 mm / 0.31 … 0.35 inches
  • Connection Data — Connection technology: antenna: 1 x SMA socket
  • Connection Data — Connection technology: device configuration: 1 x Male connector; 4-pole
  • Width: 102.5 mm / 4.035 inches
  • Height: 100 mm / 3.937 inches
  • Depth: 71.9 mm / 2.831 inches
  • Depth from upper-edge of DIN-rail: 64.7 mm / 2.547 inches
  • Mounting type: DIN-35 rail
  • Housing material: Polycarbonate; polyamide 6.6
  • Weight: 301g
  • Conformity marking: CE
  • Ambient temperature (operation): 0 … +55 °C
  • Ambient temperature (storage): -25 … +85 °C
  • Protection type: IP20
  • Pollution degree: 2 per IEC 61131-2
  • Operating altitude: without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
  • Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
  • Relative humidity (without condensation): 95%
  • Vibration resistance: Per IEC 60068-2-6
  • Shock resistance: 15g per IEC 60068-2-27
  • EMC immunity to interference: per EN 61000-6-2, marine applications
  • EMC emission of interference: per EN 61000-6-3, marine applications
  • Exposure to pollutants: per IEC 60068-2-42 and IEC 60068-2-43
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25ppm
  • Pre-contractual Information: Data-Act-750-Series-Controller