Description
The WAGO 750-8215 controller PFC200 features 2nd Generation, 4 x ETHERNET, CAN, CANopen, USB-A.
Specifications
- Communications: PROFINET RT; CANopen; Modbus TCP master/client; Modbus (UDP); ETHERNET; EtherNet/IP Adapter; EtherNet/IP Scanner; EtherCAT Master; OPC UA Server/Client; OPC UA Pub/Sub; Telecontrol protocols
- ETHERNET protocols: DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSH
- Telecontrol protocols: IEC 60870 (additional license as client or master); IEC 61850 (additional license as client or server); DNP3 (additional license as client or master)
- Visualization: Web-Visu
- Operating system: Real-time Linux (with PREEMPT_RT patch)
- CPU: Cortex A8; 1 GHz
- Programming languages per IEC 61131-3: Instruction List (IL); Ladder Diagram (LD); Function Block Diagram (FBD); Continuous Function Chart (CFC); Structured Text (ST); Sequential Function Chart (SFC)
- Programming environment: CODESYS V3.5; e!COCKPIT
- Configuration options: CODESYS V3; e!COCKPIT; WAGO-I/O-CHECK; Web-Based Management; e!RUNTIME library; CODESYS Library
- Transmission rate: ETHERNET: 10/100 Mbit/s
- Transmission medium (communication/fieldbus): ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
- Main memory (RAM): 512 MB
- Internal memory (flash): 4096 MB
- Non-volatile hardware memory: 128 kbyte
- Program memory: 32 MB
- Data memory: 128 MB
- Non-volatile software memory: 128. kbyte
- Type of memory card: SD card
- Memory Card Slot: Push-push mechanism; Cover lid (sealable)
- Number of modules per node (max.): 250
- Number of modules without a bus extension (max.): 64
- Input and output process image (internal) max.: 1000 words/1000 words
- Input and output process image (Modbus®) max.: CODESYS V3: 32000 words/32000 words
- Input and output process image (PROFINET) max.: 1024 bytes/1024 bytes
- Input and output process image (CAN) max.: 2000 words/2000 words
- Device-specific: PROFINET IO features: PROFINET IO V2.3; Media redundancy (MRP); Shared device
- Drift – system clock (25 °C): 20 ppm
- Drift – Real Time Clock (25 °C): 3 ppm
- RTC backup time (25 °C): 30 Tage
- Indicators: LED (SYS; RUN; I/O; CAN; BF; DIA; U1 … U4) red/green/orange: status system; program; local bus; CANopen; PROFINET; PROFINET diagnostics; status programmable by user (can be used via CODESYS library); LED (A, B) green: system power supply status; field supply
- Supply voltage (system): 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP® connection); External fuse required: 2 A slow-blow
- Input current (typ.) at nominal load (24 V): 550 mA
- Total current (system supply): 1,700 mA
- Supply voltage (field): 24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP® connection; distribution via spring contact); External fuse required: 10 A slow-blow
- Current carrying capacity (power jumper contacts): 10 A
- Number of outgoing power jumper contacts: 3
- Isolation: 500 V system/field
- Connection Data — Connection technology: communication/fieldbus: PROFINET: 2 x RJ-45; CANopen: 1 x D-sub 9 plug; Modbus (TCP, UDP): 2 x RJ-45
- Connection Data — Connection technology: system supply: 2 x CAGE CLAMP®
- Connection Data — Connection technology: field supply: 6 x CAGE CLAMP®
- Connection Data — Connectable conductor materials: Copper
- Connection Data — Connection type: System/field supply
- Connection Data — Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Connection Data — Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
- Connection Data — Strip length: 8 … 9 mm / 0.31 … 0.35 inches
- Connection Data — Connection technology: device configuration: 1 x Male connector; 4-pole
- Width: 112 mm / 4.409 inches
- Height: 100 mm / 3.937 inches
- Depth: 71.9 mm / 2.831 inches
- Depth from upper-edge of DIN-rail: 64.7 mm / 2.547 inches
- Mounting type: DIN-35 rail
- Housing material: Polycarbonate; polyamide 6.6
- Weight: 255.6 g
- Conformity marking: CE
- Ambient temperature (operation): 0 … +55 °C
- Ambient temperature (storage): -25 … +85 °C
- Protection type: IP20
- Pollution degree: 2 per IEC 61131-2
- Operating altitude: without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
- Mounting position: Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
- Relative humidity (without condensation): 95 %
- Vibration resistance: 4g per IEC 60068-2-6
- Shock resistance: 15g per IEC 60068-2-27
- EMC immunity to interference: per EN 61000-6-2, marine applications
- EMC emission of interference: per EN 61000-6-4, marine applications
- Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
- Permissible pollutant concentration H2S at a relative humidity < 75%: 10 ppm
- Permissible pollutant concentration SO 2 at a relative humidity < 75%: 25 ppm
- Pre-contractual Information: Data-Act-750-Series-Controller
Image shown is representative. Refer to the product specifications for the exact configuration.