Description
The WAGO 2059-902 board-to-Board Link features Pin spacing 3 mm, 2-pole, Length: 15.3 mm, white.
Specifications
- IEC Approvals — Ratings per: IEC/EN 60664-1
- IEC Approvals — Rated voltage (III / 3): 63V
- IEC Approvals — Rated impulse withstand voltage (III / 3): 2.5kV
- IEC Approvals — Rated voltage (III/2): 160V
- IEC Approvals — Rated impulse withstand voltage (III/2): 2.5kV
- IEC Approvals — Nominal voltage (II/2): 320V
- IEC Approvals — Rated impulse withstand voltage (II/2): 2.5kV
- IEC Approvals — Rated current: 3A
- IEC Approvals — Legend (ratings): (III / 2) ≙ Overvoltage category III / Pollution degree 2
- Connection Data — Total number of potentials: 2
- Connection 1 — Number of poles: 2
- Pin spacing: 3 mm / 0.118 inches
- Width: 5.7 mm / 0.224 inches
- Height: 2.5 mm / 0.098 inches
- Depth: 15.3 mm / 0.602 inches
- Mating cycles (max.): 10
- Number of mating cycles: 10 connections/disconnections (max.)
- Suitable: for SMD PCB terminal blocks (2059 Series)
- Color: white
- Insulation material (main housing): Polyamide (PA66)
- Flammability class per UL94: V0
- Contact material: Copper alloy
- Weight: 0.1g
- Limit temperature range: -60 … +105 °C
- Ambient temperature (installation): -35 … +60 °C
- Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
- Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
- Spectrum/Mounting location: Service life test, Category 1, Class A/B
- Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
- Frequency: f1 = 5 Hz to f2 = 150 Hz
- Acceleration: 0.101g (highest test level used for all axes)
- Test duration per axis: 10 min.
- Test directions: X, Y and Z axes
- Monitoring of contact faults and interruptions: Passed
- Voltage drop measurement before and after each axis: Passed
- Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
- Acceleration: 0.572g (highest test level used for all axes)
- Test duration per axis: 5 h
- Extended testing: Monitoring of contact faults and interruptions: Passed
- Extended testing: Voltage drop measurement before and after each axis: Passed
- Shock test: Test passed according to Section 10 of the standard
- Shock pulse form: Half sine
- Acceleration: 5g (highest test level used for all axes)
- Shock duration: 30 ms
- Number of shocks (per axis): 3 pos. und 3 neg.
- Vibration and shock stress for rolling stock equipment: Passed