The WAGO 2016-511 TOPJOB® S tOPJOB® S modular connector features for 2016 series, for jumper contact slot, 1-pole, gray.

Specifications

  • IEC Approvals — Rated voltage (III / 3): 500V
  • IEC Approvals — Rated impulse withstand voltage (III / 3): 6kV
  • IEC Approvals — Rated current: 32A
  • IEC Approvals — Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • General information — Wiring direction: Side-entry wiring
  • Connection Data — Clamping units: 1
  • Connection Data — Total number of potentials: 1
  • Connection 1 — Connection technology: Push-in CAGE CLAMP®
  • Connection 1 — Actuation Method: Operating tool
  • Connection 1 — Connectable conductor materials: Copper
  • Connection 1 — Nominal cross-section: 4 mm²
  • Connection 1 — Solid conductor: 0.5 … 6 mm² / 20 … 10 AWG
  • Connection 1 — Solid conductor; push-in termination: 6 mm² / 14 … 10 AWG
  • Connection 1 — Fine-stranded conductor: 0.5 … 6 mm² / 20 … 10 AWG
  • Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.5 … 4 mm² / 20 … 12 AWG
  • Connection 1 — Fine-stranded conductor; with ferrule; push-in termination: 6 mm² / 18 AWG
  • Connection 1 — Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 — Strip length: 11 … 13 mm / 0.43 … 0.51 inches
  • Connection 1 — Number of poles: 1
  • Connection 1 — Wiring direction: Side-entry wiring
  • Width: 12 mm / 0.472 inches
  • Module width: 12 mm / 0.472 inches
  • Marking level: Center/side marking
  • Color: gray
  • Insulation material (main housing): Polyamide (PA66)
  • Flammability class per UL94: V0
  • Weight: 5.3g
  • Processing temperature: -35 … +85 °C
  • Continuous operating temperature: -60 … +105 °C
  • Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
  • Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
  • Spectrum/Mounting location: Service life test, Category 1, Class A/B
  • Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
  • Frequency: f1 = 5 Hz to f2 = 150 Hz
  • Acceleration: 0.101g (highest test level used for all axes)
  • Test duration per axis: 10 min.
  • Test directions: X, Y and Z axes
  • Monitoring of contact faults and interruptions: Passed
  • Voltage drop measurement before and after each axis: Passed
  • Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
  • Acceleration: 0.572g (highest test level used for all axes)
  • Test duration per axis: 5 h
  • Extended testing: Monitoring of contact faults and interruptions: Passed
  • Extended testing: Voltage drop measurement before and after each axis: Passed
  • Shock test: Test passed according to Section 10 of the standard
  • Shock pulse form: Half sine
  • Acceleration: 5g (highest test level used for all axes)
  • Shock duration: 30 ms
  • Number of shocks (per axis): 3 pos. und 3 neg.
  • Vibration and shock stress for rolling stock equipment: Passed