Description
The WAGO 2010-1302 TOPJOB® S tOPJOB®S feedthrough terminal block features rail mount, 3-conductor, 10 mm wide, orange.
Specifications
- IEC Approvals — Ratings per: IEC/EN 60947-7-1 AC
- IEC Approvals — Rated voltage (III / 3): 800V
- IEC Approvals — Rated impulse withstand voltage (III / 3): 8kV
- IEC Approvals — Rated voltage (III/2): 1000V
- IEC Approvals — Rated impulse withstand voltage (III/2): 8kV
- IEC Approvals — Rated current: 57A
- IEC Approvals — Current at conductor cross-section (max.) mm²: 76A
- IEC Approvals — Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
- Ratings per IEC/EN 2 — Ratings per: IEC/EN 60947-7-1 DC
- Ratings per IEC/EN 2 — Rated voltage (III / 2): 1500V
- Ratings per IEC/EN 2 — Rated impulse withstand voltage (III/2): 8kV
- UL Approvals — Approvals per: UL 1059
- UL Approvals — Rated voltage UL (Use Group B): 600V
- UL Approvals — Rated current UL (Use Group B): 65A
- UL Approvals — Rated voltage UL (Use Group C): 600V
- UL Approvals — Rated current UL (Use Group C): 65A
- Approvals per: CSA 22.2 No 158
- Rated voltage CSA (Use Group B): 600V
- Rated current CSA (Use Group B): 65A
- Rated voltage CSA (Use Group C): 600V
- Rated current CSA (Use Group C): 65A
- Reference to hazardous areas: See application instructions in section “Knowledge and; Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
- Ratings per: ATEX: PTB 05 ATEX 1070 U / IECEx: PTB 06.0003U (Ex eb IIC Gb)
- Rated voltage EN (Ex e II): 550V
- Rated current (Ex e II): 50A
- Power loss, per pole (potential): 1.819W
- Rated current IN for power loss specification: 57A
- Resistance value for specified, current-dependent power loss: 0.001Ω
- General information — Wiring direction: Front-entry wiring
- Connection Data — Clamping units: 3
- Connection Data — Total number of potentials: 1
- Connection Data — Number of levels: 1
- Connection Data — Number of jumper slots: 2
- Connection 1 — Connection technology: Push-in CAGE CLAMP®
- Connection 1 — Actuation Method: Operating tool
- Connection 1 — Connectable conductor materials: Copper
- Connection 1 — Nominal cross-section: 10 mm²
- Connection 1 — Solid conductor: 0.5 … 16 mm² / 20 … 6 AWG
- Connection 1 — Solid conductor; push-in termination: 4 … 16 mm² / 14 … 6 AWG
- Connection 1 — Stranded conductor: 0.5 … 16 mm² / 20 … 6 AWG
- Connection 1 — Fine-stranded conductor: 0.5 … 16 mm² / 20 … 6 AWG
- Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.5 … 10 mm² / 20 … 8 AWG
- Connection 1 — Fine-stranded conductor; with ferrule; push-in termination: 4 … 10 mm² / 12 … 8 AWG
- Connection 1 — Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination. ; AWG specifications were converted according to IEC.
- Connection 1 — Strip length: 17 … 19 mm / 0.67 … 0.75 inches
- Connection 1 — Wiring direction: Front-entry wiring
- Width: 10 mm / 0.394 inches
- Height: 89 mm / 3.504 inches
- Depth from upper-edge of DIN-rail: 36.9 mm / 1.453 inches
- Depth: 43.5 mm / 1.713 inches
- Mounting type: DIN-35 rail
- Marking level: Center/side marking
- Color: orange
- Insulation material (main housing): Polyamide (PA66)
- Flammability class per UL94: V0
- Weight: 23.3g
- Processing temperature: -35 … +85 °C
- Continuous operating temperature: -60 … +105 °C
- Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
- Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
- Spectrum/Mounting location: Service life test, Category 1, Class A/B
- Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
- Frequency: f1 = 5 Hz to f2 = 150 Hz
- Acceleration: 0.101g (highest test level used for all axes)
- Test duration per axis: 10 min.
- Test directions: X, Y and Z axes
- Monitoring of contact faults and interruptions: Passed
- Voltage drop measurement before and after each axis: Passed
- Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
- Acceleration: 0.572g (highest test level used for all axes)
- Test duration per axis: 5 h
- Extended testing: Monitoring of contact faults and interruptions: Passed
- Extended testing: Voltage drop measurement before and after each axis: Passed
- Shock test: Test passed according to Section 10 of the standard
- Shock pulse form: Half sine
- Acceleration: 5g (highest test level used for all axes)
- Shock duration: 30 ms
- Number of shocks (per axis): 3 pos. und 3 neg.
- Vibration and shock stress for rolling stock equipment: Passed