null

WAGO 2002-2257 TOPJOB®S double-deck terminal block, ground/through (PE/L), with marker carrier, rail mount, 2-conductor, 5.2 mm wide, gray

$9.42
SKU:
2002-2257
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.


Manufacturer Information

Wago orders require a $100 combined minimum order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

The WAGO 2002-2257 TOPJOB® S tOPJOB®S double-deck terminal block features ground/through (PE/L), with marker carrier, rail mount, 2-conductor, 5.2 mm wide, gray.

Specifications

  • IEC Approvals — Ratings per: IEC/EN 60947-7-1
  • IEC Approvals — Rated voltage (III / 3): 500V
  • IEC Approvals — Rated impulse withstand voltage (III / 3): 6kV
  • IEC Approvals — Rated current: 24A
  • IEC Approvals — Current at conductor cross-section (max.) mm²: 28A
  • IEC Approvals — Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
  • UL Approvals — Approvals per: UL 1059
  • UL Approvals — Rated voltage UL (Use Group B): 300V
  • UL Approvals — Rated current UL (Use Group B): 20A
  • UL Approvals — Rated voltage UL (Use Group C): 300V
  • UL Approvals — Rated current UL (Use Group C): 20A
  • UL Approvals — Rated voltage UL (Use Group D): 600V
  • UL Approvals — Rated current UL (Use Group D): 5A
  • Approvals per: CSA 22.2 No 158
  • Rated voltage CSA (Use Group B): 300V
  • Rated current CSA (Use Group B): 20A
  • Rated voltage CSA (Use Group C): 300V
  • Rated current CSA (Use Group C): 20A
  • Reference to hazardous areas: See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
  • Ratings per: ATEX: PTB 03 ATEX 1162 U / IECEx: PTB 03.0004U (Ex eb IIC Gb)
  • Rated voltage EN (Ex e II): 440V
  • Rated current (Ex e II): 20A
  • Rated current (Ex e II) with jumper: 18A
  • Power loss, per pole (potential): 0.766W
  • Rated current IN for power loss specification: 24A
  • Resistance value for specified, current-dependent power loss: 0.001Ω
  • General information — Wiring direction: Front-entry wiring
  • Connection Data — Clamping units: 4
  • Connection Data — Total number of potentials: 2
  • Connection Data — Number of levels: 2
  • Connection Data — Number of jumper slots: 4
  • Connection 1 — Connection technology: Push-in CAGE CLAMP®
  • Connection 1 — Actuation Method: Operating tool
  • Connection 1 — Connectable conductor materials: Copper
  • Connection 1 — Nominal cross-section: 2.5 mm²
  • Connection 1 — Solid conductor: 0.25 … 4 mm² / 22 … 12 AWG
  • Connection 1 — Solid conductor; push-in termination: 0.75 … 4 mm² / 18 … 12 AWG
  • Connection 1 — Fine-stranded conductor: 0.25 … 4 mm² / 22 … 12 AWG
  • Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.25 … 2.5 mm² / 22 … 14 AWG
  • Connection 1 — Fine-stranded conductor; with ferrule; push-in termination: 1 … 2.5 mm² / 18 … 14 AWG
  • Connection 1 — Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
  • Connection 1 — Strip length: 10 … 12 mm / 0.39 … 0.47 inches
  • Connection 1 — Wiring direction: Front-entry wiring
  • Width: 5.2 mm / 0.205 inches
  • Height: 69.7 mm / 2.744 inches
  • Depth from upper-edge of DIN-rail: 61.8 mm / 2.433 inches
  • Potential Marking: PE/L
  • Mounting type: DIN-35 rail
  • Marking level: Center/side marking
  • Color: gray
  • Insulation material (main housing): Polyamide (PA66)
  • Flammability class per UL94: V0
  • Weight: 13.3g
  • Processing temperature: -35 … +85 °C
  • Continuous operating temperature: -60 … +105 °C
  • Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
  • Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
  • Spectrum/Mounting location: Service life test, Category 1, Class A/B
  • Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
  • Frequency: f1 = 5 Hz to f2 = 150 Hz
  • Acceleration: 0.101g (highest test level used for all axes)
  • Test duration per axis: 10 min.
  • Test directions: X, Y and Z axes
  • Monitoring of contact faults and interruptions: Passed
  • Voltage drop measurement before and after each axis: Passed
  • Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
  • Acceleration: 0.572g (highest test level used for all axes)
  • Test duration per axis: 5 h
  • Extended testing: Monitoring of contact faults and interruptions: Passed
  • Extended testing: Voltage drop measurement before and after each axis: Passed
  • Shock test: Test passed according to Section 10 of the standard
  • Shock pulse form: Half sine
  • Acceleration: 5g (highest test level used for all axes)
  • Shock duration: 30 ms
  • Number of shocks (per axis): 3 pos. und 3 neg.
  • Vibration and shock stress for rolling stock equipment: Passed