Description
The WAGO 2002-2204 TOPJOB® S tOPJOB®S double-deck terminal block features through/through (N/N), rail mount, 2-conductor, 5.2 mm wide, gray.
Specifications
- IEC Approvals — Ratings per: IEC/EN 60947-7-1
- IEC Approvals — Rated voltage (III / 3): 500V
- IEC Approvals — Rated impulse withstand voltage (III / 3): 6kV
- IEC Approvals — Rated current: 24A
- IEC Approvals — Current at conductor cross-section (max.) mm²: 28A
- IEC Approvals — Legend (ratings): (III / 3) ≙ Overvoltage category III / Pollution degree 3
- UL Approvals — Approvals per: UL 1059
- UL Approvals — Rated voltage UL (Use Group B): 300V
- UL Approvals — Rated current UL (Use Group B): 20A
- UL Approvals — Rated voltage UL (Use Group C): 300V
- UL Approvals — Rated current UL (Use Group C): 20A
- UL Approvals — Rated voltage UL (Use Group D): 600V
- UL Approvals — Rated current UL (Use Group D): 5A
- Approvals per: CSA 22.2 No 158
- Rated voltage CSA (Use Group B): 300V
- Rated current CSA (Use Group B): 20A
- Rated voltage CSA (Use Group C): 300V
- Rated current CSA (Use Group C): 20A
- Reference to hazardous areas: See “Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
- Ratings per: ATEX: PTB 03 ATEX 1162 U / IECEx: PTB 03.0004U (Ex eb IIC Gb)
- Rated voltage EN (Ex e II): 440V
- Rated current (Ex e II): 20A
- Rated current (Ex e II) with jumper: 18A
- Power loss, per pole (potential): 0.766W
- Rated current IN for power loss specification: 24A
- Resistance value for specified, current-dependent power loss: 0.001Ω
- General information — Wiring direction: Front-entry wiring
- Connection Data — Clamping units: 4
- Connection Data — Total number of potentials: 2
- Connection Data — Number of levels: 2
- Connection Data — Number of jumper slots: 4
- Connection 1 — Connection technology: Push-in CAGE CLAMP®
- Connection 1 — Actuation Method: Operating tool
- Connection 1 — Connectable conductor materials: Copper
- Connection 1 — Nominal cross-section: 2.5 mm²
- Connection 1 — Solid conductor: 0.25 … 4 mm² / 22 … 12 AWG
- Connection 1 — Solid conductor; push-in termination: 0.75 … 4 mm² / 18 … 12 AWG
- Connection 1 — Fine-stranded conductor: 0.25 … 4 mm² / 22 … 12 AWG
- Connection 1 — Fine-stranded conductor; with insulated ferrule: 0.25 … 2.5 mm² / 22 … 14 AWG
- Connection 1 — Fine-stranded conductor; with ferrule; push-in termination: 1 … 2.5 mm² / 18 … 14 AWG
- Connection 1 — Note (conductor cross-section): Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- Connection 1 — Strip length: 10 … 12 mm / 0.39 … 0.47 inches
- Connection 1 — Wiring direction: Front-entry wiring
- Width: 5.2 mm / 0.205 inches
- Height: 69.7 mm / 2.744 inches
- Depth from upper-edge of DIN-rail: 51.7 mm / 2.035 inches
- Potential Marking: N/N
- Mounting type: DIN-35 rail
- Marking level: Center/side marking
- Color: blue
- Insulation material (main housing): Polyamide (PA66)
- Flammability class per UL94: V0
- Weight: 10.2g
- Processing temperature: -35 … +85 °C
- Continuous operating temperature: -60 … +105 °C
- Test specification: ; Railway applications –; Rolling stock –; Electronic equipment: DIN EN 50155 (VDE 0115-200):2022-06
- Test procedure: ; Railway applications – ; Rolling stock equipment – ; Vibration and shock tests: DIN EN 61373 (VDE 0115-0106):2011-04
- Spectrum/Mounting location: Service life test, Category 1, Class A/B
- Functional test with noise-like oscillations: Test passed according to Section 8 of the standard
- Frequency: f1 = 5 Hz to f2 = 150 Hz
- Acceleration: 0.101g (highest test level used for all axes)
- Test duration per axis: 10 min.
- Test directions: X, Y and Z axes
- Monitoring of contact faults and interruptions: Passed
- Voltage drop measurement before and after each axis: Passed
- Simulated service life test through increased levels of noise-like oscillations: Test passed according to Section 9 of the standard
- Acceleration: 0.572g (highest test level used for all axes)
- Test duration per axis: 5 h
- Extended testing: Monitoring of contact faults and interruptions: Passed
- Extended testing: Voltage drop measurement before and after each axis: Passed
- Shock test: Test passed according to Section 10 of the standard
- Shock pulse form: Half sine
- Acceleration: 5g (highest test level used for all axes)
- Shock duration: 30 ms
- Number of shocks (per axis): 3 pos. und 3 neg.
- Vibration and shock stress for rolling stock equipment: Passed