Tripp-Lite SMX700HG SmartPro 230V 700VA 450W Medical-Grade Line-Interactive Tower UPS

$1,038.99
SKU:
SMX700HG
Shipping:
Calculated at Checkout
Product Type:
Single Phase UPS
Type:
Line-Interactive

Product Overview

Overview

Tripp Lite’s SMX700HG medical-grade UPS system provides dependable battery backup and is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient-care vicinities. The 700VA/450W capacity provides up to 36 minutes of runtime for a half load, or 14.5 minutes for a full load so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout.
Built-in line-interactive voltage regulation corrects brownouts as low as 155V and overvoltages as high as 274V to normal 230V nominal output, without drawing battery power. The SMX700HG’s built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Cumulative leakage current of all connected equipment is less than 100 microamps.
This UPS system features six IEC320 C13 hospital-grade outlets and has a hospital-grade IEC320 C14 plug on a 15 cm (6 in.) dongle. All six outlets provide both backup protection and surge protection, rated to 340 joules.
The SMX700HG also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with Tripp Lite’s free downloadable PowerAlert software for safe, unattended system shutdown and file saves in the event of a prolonged power failure.
Application Usage
This UPS contains a lead acid battery designed to be connected continuously to an AC power source, except during brief power outages. It is not intended for frequent charge/discharge cycles, such as mobile cart applications where the UPS is often disconnected from the power source. Using the SMX700HG in this type of application will void the battery warranty.

Features

Provides Ideal UPS Backup in Healthcare Facilities
  • Compliant with UL 60601-1 standards for use in patient-care vicinities, when plugged into a hospital-grade outlet
  • Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise

Battery Backup and Full Surge Protection

  • 36 minutes runtime for half load (225W); 14.5 minutes for full load (450W)
  • All six hospital-grade outlets provide surge protection rated to 340 joules
  • EMI/RFI noise filtering ensures equipment runs smoothly without line noise interference
  • Resistant to electrostatic discharge

LEDs and Audible Alarms Keep You Aware of Power Status

  • Indicator lights on the front of the unit show you when the UPS is on and supplying utility power, when operating in voltage correction mode or in battery mode, relative load level and low-battery warning
  • Audible alarms alert you to power failure, overload and low battery conditions; the alarm’s mute/quiet mode ensures patients are not disturbed

Saves Your Files, Even When You’re Away

  • Works with Tripp Lite PowerAlert software (available as a free download) to enable safe, unattended system shutdown and files saves during prolonged power failures
  • Connects to your computer via either the DB9 port or USB port

Package Includes

  • SMX700HG 700VA/450W Medical-Grade Tower UPS System
  • USB monitoring cable, 1.8 m (6 ft.)
  • DB9 serial monitoring cable, 1.8 m (6 ft.)
  • Owner’s Manual
Cisco compatible RoHS compliant VMware ready application

Specifications

OVERVIEW
UPC Code 037332140418
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 3.6A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Cord Length (ft.) 0.50
Recommended Electrical Service 10A 230V
Voltage Compatibility (VAC) 230
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 700
Output Watt Capacity (Watts) 450
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -18%, +8%
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (6) C13
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)   14.5 min. (450w)
Half Load Runtime (min.)   36 min. (225w)
Expandable Runtime No
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 3.6 hours from 10% to 90% (typical, full load discharge)
Battery Access Battery access door allows hot swap battery replacement without powering connected equipment off
Internal UPS Replacement Battery Cartridge RBC36SLT
Typical Battery Lifespan 3-6 years, depending on usage
VOLTAGE REGULATION
Voltage Regulation Description Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC
Overvoltage Correction   Input voltages between 206 and 245V AC are reduced by 9%
Undervoltage Correction   Input voltages between 183 and 199 are boosted by 10%
Severe Undervoltage Correction Input voltages between 155 and 182 are boosted by 21%
USER INTERFACE, ALERTS & CONTROLS
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Audible Alarm 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software.
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 340
EMI / RFI AC Noise Suppression   Yes
AC Suppression Response Time   Instantaneous
PHYSICAL
Primary Form Factor Tower
Cooling Method Cooling via rear-exit cooling fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  - tower mounting kit)
Primary UPS Depth (mm) 229
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / in.) 18.50 x 12.20 x 13.38
Shipping Weight (lbs.) 45.40
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, in.) 12.8 x 7.5 x 9
UPS Power Module Weight (kg) 19.10
UPS Power Module Weight (lbs.) 42.1
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   208.6
Battery Mode BTU / Hr. (Full Load)   189.1
COMMUNICATIONS
Network Management Card Description Network management not supported
Communications Interface USB; DB9 Serial
LINE / BATTERY TRANSFER
Transfer Time   5 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 155
High Voltage Transfer to Battery Power (Setpoint) 274
FEATURES & SPECIFICATIONS
Grounding Lug Equipotential connection (back panel grounding lug)
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Surge/noise protection
STANDARDS & COMPLIANCE
UPS Certifications CE; Tested to UL60601-1 (medical grade)
WARRANTY
Product Warranty Period (International) 2-year limited warranty

Overview

Tripp Lite’s SMX700HG medical-grade UPS system provides dependable battery backup and is fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient-care vicinities. The 700VA/450W capacity provides up to 36 minutes of runtime for a half load, or 14.5 minutes for a full load so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout.
Built-in line-interactive voltage regulation corrects brownouts as low as 155V and overvoltages as high as 274V to normal 230V nominal output, without drawing battery power. The SMX700HG’s built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. Cumulative leakage current of all connected equipment is less than 100 microamps.
This UPS system features six IEC320 C13 hospital-grade outlets and has a hospital-grade IEC320 C14 plug on a 15 cm (6 in.) dongle. All six outlets provide both backup protection and surge protection, rated to 340 joules.
The SMX700HG also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with Tripp Lite’s free downloadable PowerAlert software for safe, unattended system shutdown and file saves in the event of a prolonged power failure.
Application Usage
This UPS contains a lead acid battery designed to be connected continuously to an AC power source, except during brief power outages. It is not intended for frequent charge/discharge cycles, such as mobile cart applications where the UPS is often disconnected from the power source. Using the SMX700HG in this type of application will void the battery warranty.

Features

Provides Ideal UPS Backup in Healthcare Facilities
  • Compliant with UL 60601-1 standards for use in patient-care vicinities, when plugged into a hospital-grade outlet
  • Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise

Battery Backup and Full Surge Protection

  • 36 minutes runtime for half load (225W); 14.5 minutes for full load (450W)
  • All six hospital-grade outlets provide surge protection rated to 340 joules
  • EMI/RFI noise filtering ensures equipment runs smoothly without line noise interference
  • Resistant to electrostatic discharge

LEDs and Audible Alarms Keep You Aware of Power Status

  • Indicator lights on the front of the unit show you when the UPS is on and supplying utility power, when operating in voltage correction mode or in battery mode, relative load level and low-battery warning
  • Audible alarms alert you to power failure, overload and low battery conditions; the alarm’s mute/quiet mode ensures patients are not disturbed

Saves Your Files, Even When You’re Away

  • Works with Tripp Lite PowerAlert software (available as a free download) to enable safe, unattended system shutdown and files saves during prolonged power failures
  • Connects to your computer via either the DB9 port or USB port

Package Includes

  • SMX700HG 700VA/450W Medical-Grade Tower UPS System
  • USB monitoring cable, 1.8 m (6 ft.)
  • DB9 serial monitoring cable, 1.8 m (6 ft.)
  • Owner’s Manual
Cisco compatible RoHS compliant VMware ready application

Specifications

OVERVIEW
UPC Code 037332140418
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 3.6A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Cord Length (ft.) 0.50
Recommended Electrical Service 10A 230V
Voltage Compatibility (VAC) 230
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 700
Output Watt Capacity (Watts) 450
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -18%, +8%
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (6) C13
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)   14.5 min. (450w)
Half Load Runtime (min.)   36 min. (225w)
Expandable Runtime No
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 3.6 hours from 10% to 90% (typical, full load discharge)
Battery Access Battery access door allows hot swap battery replacement without powering connected equipment off
Internal UPS Replacement Battery Cartridge RBC36SLT
Typical Battery Lifespan 3-6 years, depending on usage
VOLTAGE REGULATION
Voltage Regulation Description Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC
Overvoltage Correction   Input voltages between 206 and 245V AC are reduced by 9%
Undervoltage Correction   Input voltages between 183 and 199 are boosted by 10%
Severe Undervoltage Correction Input voltages between 155 and 182 are boosted by 21%
USER INTERFACE, ALERTS & CONTROLS
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Audible Alarm 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software.
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 340
EMI / RFI AC Noise Suppression   Yes
AC Suppression Response Time   Instantaneous
PHYSICAL
Primary Form Factor Tower
Cooling Method Cooling via rear-exit cooling fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  - tower mounting kit)
Primary UPS Depth (mm) 229
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / in.) 18.50 x 12.20 x 13.38
Shipping Weight (lbs.) 45.40
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, in.) 12.8 x 7.5 x 9
UPS Power Module Weight (kg) 19.10
UPS Power Module Weight (lbs.) 42.1
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   208.6
Battery Mode BTU / Hr. (Full Load)   189.1
COMMUNICATIONS
Network Management Card Description Network management not supported
Communications Interface USB; DB9 Serial
LINE / BATTERY TRANSFER
Transfer Time   5 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 155
High Voltage Transfer to Battery Power (Setpoint) 274
FEATURES & SPECIFICATIONS
Grounding Lug Equipotential connection (back panel grounding lug)
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Surge/noise protection
STANDARDS & COMPLIANCE
UPS Certifications CE; Tested to UL60601-1 (medical grade)
WARRANTY
Product Warranty Period (International) 2-year limited warranty