null

Tripp-Lite SMART3000RM2UL 120V 3kVA Line Interactive SmartPro UPS

$4,004.99
SKU:
SMART3000RM2UL
Shipping:
Calculated at Checkout
Product Type:
Single Phase UPS
Type:
Line-Interactive

Product Overview

Features

Reliable LiFePO4 Battery Backup Offers Longer Life and Less Weight than Lead Acid Battery
This Tripp Lite SmartPro® UPS system features a state-of-the-art lithium iron phosphate (LiFePO4) internal battery with longer life, more cycles and faster recharge. It more than doubles the service life of an equivalent lead acid battery, and offers up to three times more charge/discharge cycles. It recharges to 100-percent capacity in less than two hours, making the lithium UPS system an ideal backup in case of power outage. The LiFePO4 battery weighs 60-percent less than an equivalent lead acid battery, which reduces the overall UPS weight.
120-Volt Battery Backup Keeps Equipment Operating Through Short Power Failures
The SMART3000RM2UL provides up to 9.5 minutes (half load) and 3.5 minutes (full load) of battery backup, as well as AC power protection, for critical server, network and telecom equipment. In case of a prolonged blackout, the single-phase UPS system gives you enough time to save important data and perform an orderly system shutdown. With a 2250W capacity (3000VA), the line-interactive UPS system with automatic voltage regulation (AVR) maintains regulated 120V nominal output over an input range of 83V-145V without using battery power.
Protect Your Mission-Critical Rack Equipment
Plug your equipment into the eight NEMA 5-15/20R and one NEMA L5-30R outlets. Two 5-15/20R outlets are switchable, allowing you to power connected equipment on and off remotely to reset or reboot connected equipment or to shed less significant loads to extend battery runtime for more critical equipment. All nine outlets are protected by 570-joule network-grade surge protection to fight off damaging power surges and spikes.
High Efficiency Operation Helps the Environment and Your Cash Flow
Operating with a high 98% line-mode efficiency, this 3kVA UPS system can save BTU heat output and energy costs.
Advanced Communications Ports Connect to Any Workstation or Server
USB and DB9 ports (cables are included) enable data-saving unattended shutdown when used with Tripp Lite's free downloadable PowerAlert® software. Capabilities include monitoring of equipment load level, self-test data and utility power conditions. The Emergency Power Off (EPO) interface offers options for instantaneous power-off of the UPS system and connected equipment in case of fire or other facility emergency. The SMART3000RM2UL is compatible with Tripp Lite network management cards, such as WEBCARDLX, for detailed monitoring of UPS and site power conditions.
Multi-Function LCD and Audible Alarms Keep You Informed
The front-panel LCD information and configuration screen displays detailed UPS and site power status and operating data, as well as input and output voltage, operating mode, alarm function and additional options. An alarm sounds to warn you of power failure, low battery, overload, UPS fault and remote shutdown conditions.
Versatile Installation Options
Hardware is included for mounting the Tripp Lite SmartPro UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM for 2-post rack mounting or wall mounting. Use the optional 2-9USTAND for mounting in an upright tower position. A 10-ft. (3.05 m) power cord with NEMA L5-30P plug connects the SMART3000RM2UL to a compatible AC power source.
5-Year Warranty and $250K Ultimate Lifetime Insurance
The SMART3000RM2UL comes with a 5-year warranty and $250,000 of Ultimate Lifetime Insurance for any connected components damaged by a power surge (U.S., Canada and Puerto Rico only).

Package Includes

  • SMART3000RM2UL SmartPro UPS, Lithium Battery Backup
  • USB cable
  • DB9 cable
  • EPO cable
  • Rack-mounting hardware
  • Owner’s manual
Cisco compatible RoHS compliant
 

Specifications

OVERVIEW
UPC Code 037332207159
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 24A (120V)
Nominal Input Voltage(s) Supported 110V AC; 115V AC; 120V AC
UPS Input Connection Type L5-30P
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 30A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output Capacity (kVA) 3.0
Output Watt Capacity (Watts) 2250
Output kW Capacity (kW) 2.25
Power Factor   0.75
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) -14%, +6%
Output Voltage Regulation (Battery Mode) +/- 5%
Load Management Receptacles   Two switchable single-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (8) 5-15/20R; (1) L5-30R
Individually Controllable Load Banks   Yes
BATTERY
Battery Type Lithium Ion
Full Load Runtime (min.)   3.5 min. (2250w)
Half Load Runtime (min.)   9.5 min. (1125w)
Expandable Runtime No
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) 1.7 hours from 10% to 90% (typical, full load discharge)
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage Correction   Input voltages between 127 and 145 are reduced by 12%
Undervoltage Correction   Input voltages between 108 and 96 are boosted by 12%
Severe Undervoltage Correction Input voltages between 83 and 95 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Rackmount
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth (inches) 24.5
Optional Mounting Accessory Notes Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm) 494
Primary UPS Height (mm) 87
Primary UPS Width (mm) 440
Rack Height 2U
Shipping Dimensions (hwd / in.) 8.40 x 23.80 x 21.70
Shipping Weight (lbs.) 63.90
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 3.43 x 17.32 x 19.46
UPS Power Module Weight (kg) 22.72
UPS Power Module Weight (lbs.) 50.1
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   189
AC Mode Efficiency Rating (100% Load) 98%
Audible Noise 50.3 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards  WEBCARDLX ;  RELAYIOCARD ;  SNMPWEBCARD 
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Available via free download from tripplite.com/poweralert
Communications Cable USB, DB9 and EPO cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools Compatibility NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
Network Management Card Description Network management card optional
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   5 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
Low Voltage Transfer to Battery Power (Setpoint) 83
High Voltage Transfer to Battery Power (Setpoint) 145
FEATURES & SPECIFICATIONS
Grounding Lug Back panel grounding lug
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Remote management; Sine wave output; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
STANDARDS & COMPLIANCE
UPS Certifications Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Certification Details SAFETY STANDARD (U.S.) - UL1778:2014 (5th Ed) R10.17; SAFETY STANDARD (CANADA) - CAN/CSA-C22.2 No. 107.3-14 (3rd Ed) + GI1 / FCC/ICES COMPLIANT - CLASS A
WARRANTY
Product Warranty Period (Worldwide) 5-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance 

Features

Reliable LiFePO4 Battery Backup Offers Longer Life and Less Weight than Lead Acid Battery
This Tripp Lite SmartPro® UPS system features a state-of-the-art lithium iron phosphate (LiFePO4) internal battery with longer life, more cycles and faster recharge. It more than doubles the service life of an equivalent lead acid battery, and offers up to three times more charge/discharge cycles. It recharges to 100-percent capacity in less than two hours, making the lithium UPS system an ideal backup in case of power outage. The LiFePO4 battery weighs 60-percent less than an equivalent lead acid battery, which reduces the overall UPS weight.
120-Volt Battery Backup Keeps Equipment Operating Through Short Power Failures
The SMART3000RM2UL provides up to 9.5 minutes (half load) and 3.5 minutes (full load) of battery backup, as well as AC power protection, for critical server, network and telecom equipment. In case of a prolonged blackout, the single-phase UPS system gives you enough time to save important data and perform an orderly system shutdown. With a 2250W capacity (3000VA), the line-interactive UPS system with automatic voltage regulation (AVR) maintains regulated 120V nominal output over an input range of 83V-145V without using battery power.
Protect Your Mission-Critical Rack Equipment
Plug your equipment into the eight NEMA 5-15/20R and one NEMA L5-30R outlets. Two 5-15/20R outlets are switchable, allowing you to power connected equipment on and off remotely to reset or reboot connected equipment or to shed less significant loads to extend battery runtime for more critical equipment. All nine outlets are protected by 570-joule network-grade surge protection to fight off damaging power surges and spikes.
High Efficiency Operation Helps the Environment and Your Cash Flow
Operating with a high 98% line-mode efficiency, this 3kVA UPS system can save BTU heat output and energy costs.
Advanced Communications Ports Connect to Any Workstation or Server
USB and DB9 ports (cables are included) enable data-saving unattended shutdown when used with Tripp Lite's free downloadable PowerAlert® software. Capabilities include monitoring of equipment load level, self-test data and utility power conditions. The Emergency Power Off (EPO) interface offers options for instantaneous power-off of the UPS system and connected equipment in case of fire or other facility emergency. The SMART3000RM2UL is compatible with Tripp Lite network management cards, such as WEBCARDLX, for detailed monitoring of UPS and site power conditions.
Multi-Function LCD and Audible Alarms Keep You Informed
The front-panel LCD information and configuration screen displays detailed UPS and site power status and operating data, as well as input and output voltage, operating mode, alarm function and additional options. An alarm sounds to warn you of power failure, low battery, overload, UPS fault and remote shutdown conditions.
Versatile Installation Options
Hardware is included for mounting the Tripp Lite SmartPro UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM for 2-post rack mounting or wall mounting. Use the optional 2-9USTAND for mounting in an upright tower position. A 10-ft. (3.05 m) power cord with NEMA L5-30P plug connects the SMART3000RM2UL to a compatible AC power source.
5-Year Warranty and $250K Ultimate Lifetime Insurance
The SMART3000RM2UL comes with a 5-year warranty and $250,000 of Ultimate Lifetime Insurance for any connected components damaged by a power surge (U.S., Canada and Puerto Rico only).

Package Includes

  • SMART3000RM2UL SmartPro UPS, Lithium Battery Backup
  • USB cable
  • DB9 cable
  • EPO cable
  • Rack-mounting hardware
  • Owner’s manual
Cisco compatible RoHS compliant
 

Specifications

OVERVIEW
UPC Code 037332207159
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 24A (120V)
Nominal Input Voltage(s) Supported 110V AC; 115V AC; 120V AC
UPS Input Connection Type L5-30P
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 30A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output Capacity (kVA) 3.0
Output Watt Capacity (Watts) 2250
Output kW Capacity (kW) 2.25
Power Factor   0.75
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) -14%, +6%
Output Voltage Regulation (Battery Mode) +/- 5%
Load Management Receptacles   Two switchable single-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (8) 5-15/20R; (1) L5-30R
Individually Controllable Load Banks   Yes
BATTERY
Battery Type Lithium Ion
Full Load Runtime (min.)   3.5 min. (2250w)
Half Load Runtime (min.)   9.5 min. (1125w)
Expandable Runtime No
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) 1.7 hours from 10% to 90% (typical, full load discharge)
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage Correction   Input voltages between 127 and 145 are reduced by 12%
Undervoltage Correction   Input voltages between 108 and 96 are boosted by 12%
Severe Undervoltage Correction Input voltages between 83 and 95 are boosted by 24%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Rackmount
Cooling Method Fan
Included Mounting Accessory Description Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )
Minimum Required Rack Depth (inches) 24.5
Optional Mounting Accessory Notes Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support
Primary UPS Depth (mm) 494
Primary UPS Height (mm) 87
Primary UPS Width (mm) 440
Rack Height 2U
Shipping Dimensions (hwd / in.) 8.40 x 23.80 x 21.70
Shipping Weight (lbs.) 63.90
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, in.) 3.43 x 17.32 x 19.46
UPS Power Module Weight (kg) 22.72
UPS Power Module Weight (lbs.) 50.1
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   189
AC Mode Efficiency Rating (100% Load) 98%
Audible Noise 50.3 dBA maximum, front side 1m
COMMUNICATIONS
Network Management Cards  WEBCARDLX ;  RELAYIOCARD ;  SNMPWEBCARD 
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software Available via free download from tripplite.com/poweralert
Communications Cable USB, DB9 and EPO cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools Compatibility NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
Network Management Card Description Network management card optional
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   5 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
Low Voltage Transfer to Battery Power (Setpoint) 83
High Voltage Transfer to Battery Power (Setpoint) 145
FEATURES & SPECIFICATIONS
Grounding Lug Back panel grounding lug
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Auto Probe Monitoring and Reboot (requires WEBCARDLX); Automatic Voltage Regulation (AVR); Remote management; Sine wave output; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
STANDARDS & COMPLIANCE
UPS Certifications Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Certification Details SAFETY STANDARD (U.S.) - UL1778:2014 (5th Ed) R10.17; SAFETY STANDARD (CANADA) - CAN/CSA-C22.2 No. 107.3-14 (3rd Ed) + GI1 / FCC/ICES COMPLIANT - CLASS A
WARRANTY
Product Warranty Period (Worldwide) 5-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance