null

Tripp-Lite SMART1500LCDT SmartPro LCD 120V 50/60Hz 1500VA 900W Line-Interactive UPS

$344.99
SKU:
SMART1500LCDT
Shipping:
Calculated at Checkout
Product Type:
Single Phase UPS
Type:
Line-Interactive

Product Overview

Overview

The SMART1500LCDT SmartPro LCD 120V, 1500VA/900W Line-Interactive Uninterruptible Power Supply provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss.

While all ten NEMA 5-15R outlets protect against surges, five outlets also provide up to 90 minutes of UPS battery support for a basic desktop PC and LCD monitor and up to 10 minutes of support at half load (450W). 

Automatic voltage regulation (AVR) corrects undervoltages as low as 92V and overvoltages as high as 150V without using any battery power. EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 650-joule surge suppression rating protects your equipment from harmful power surges.

NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket. Large LCD screen shows real-time input voltage, overload, AVR, remaining battery runtime and battery statuses at a glance. Alarm sounds to indicate power loss or low battery. With Tripp Lite's PowerAlert software (available via free download), SMART1500LCDT enables safe unattended system shutdown and file saves in case of a prolonged power failure.

Features

Reliable Battery Backup

  • Provides 1500VA/900W high-performance power protection for desktop computers, audio/video components, media centers and other electronics
  • Supports basic desktop computer and LCD monitor up to 90 minutes during power outage
  • Supports 50% load (450W) up to 10 minutes
  • Audible alarm indicates loss of utility power or low battery

Optimized Outlets

  • 5 NEMA 5-15R outlets deliver battery backup for devices that require constant power
  • All 10 outlets protect against surges or spikes that can harm equipment or data
  • NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket

Automatic Voltage Regulation (AVR)

  • Corrects undervoltages as low as 92V and overvoltages as high as 150V without drawing battery backup power

LCD Status Screen

  • Large LCD screen shows real-time input voltage, overload, AVR and battery statuses
  • Automatically displays remaining battery runtime in minutes during power outage

AC Line, Tel/DSL and Ethernet Surge Suppression

  • Surge suppression rating of 650 joules protects connected equipment and data from harmful power surges
  • Tel/DSL RJ11 jacks protect standard dial-up/DSL/Ethernet phone connection
  • Coaxial jacks protect CATV, broadband cable internet, satellite or broadcast antenna connection

EMI/RFI Line Noise Filtering

  • Removes electromagnetic and radio frequency interference that can disrupt or damage your equipment's performance

USB Communication Port and Free PowerAlert Software

  • HID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and Mac OS X
  • USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert

Package Includes

  • SMART1500LCDT SmartPro LCD 120V 1500VA/900W Line-Interactive UPS
  • USB cable
  • Owner’s Manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332174109
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 12A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 20A
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output Capacity (kVA) 1.5
Output Watt Capacity (Watts) 900
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) 120V (+9% / -12%)
Output Voltage Regulation (Battery Mode) 120V (±10%)
UPS Output Receptacles (Surge Suppression Only) 5 UPS outlets, 5 surge-only outlets
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (10) 5-15R
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Half Load Runtime (min.)   10 minutes (450 watts)
Expandable Runtime No
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge  RBC51  (requires 2)
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150
Overvoltage Correction   Input voltages between 129 and 147 are reduced by 15%
Undervoltage Correction   Input voltages between 92 and 108 are boosted by 18%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes
Switches Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 650
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 391
Primary UPS Height (mm) 203
Primary UPS Width (mm) 146
Shipping Dimensions (hwd / in.) 11.10 x 9.00 x 19.30
Shipping Weight (lbs.) 28.00
UPS Power Module Dimensions (hwd, in.) 8 x 5.75 x 15.4
UPS Power Module Weight (kg) 12.25
UPS Power Module Weight (lbs.) 27
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   119
Battery Mode BTU / Hr. (Full Load)   867
AC Mode Efficiency Rating (100% Load) 95%
Audible Noise Less than 36 dB, front side 1m
COMMUNICATIONS
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management not supported
Communications Interface USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)
Low Voltage Transfer to Battery Power (Setpoint) 92
High Voltage Transfer to Battery Power (Setpoint) 150
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS
STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (U.S. & Canada) 3-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance 

Overview

The SMART1500LCDT SmartPro LCD 120V, 1500VA/900W Line-Interactive Uninterruptible Power Supply provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss.

While all ten NEMA 5-15R outlets protect against surges, five outlets also provide up to 90 minutes of UPS battery support for a basic desktop PC and LCD monitor and up to 10 minutes of support at half load (450W). 

Automatic voltage regulation (AVR) corrects undervoltages as low as 92V and overvoltages as high as 150V without using any battery power. EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 650-joule surge suppression rating protects your equipment from harmful power surges.

NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket. Large LCD screen shows real-time input voltage, overload, AVR, remaining battery runtime and battery statuses at a glance. Alarm sounds to indicate power loss or low battery. With Tripp Lite's PowerAlert software (available via free download), SMART1500LCDT enables safe unattended system shutdown and file saves in case of a prolonged power failure.

Features

Reliable Battery Backup

  • Provides 1500VA/900W high-performance power protection for desktop computers, audio/video components, media centers and other electronics
  • Supports basic desktop computer and LCD monitor up to 90 minutes during power outage
  • Supports 50% load (450W) up to 10 minutes
  • Audible alarm indicates loss of utility power or low battery

Optimized Outlets

  • 5 NEMA 5-15R outlets deliver battery backup for devices that require constant power
  • All 10 outlets protect against surges or spikes that can harm equipment or data
  • NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket

Automatic Voltage Regulation (AVR)

  • Corrects undervoltages as low as 92V and overvoltages as high as 150V without drawing battery backup power

LCD Status Screen

  • Large LCD screen shows real-time input voltage, overload, AVR and battery statuses
  • Automatically displays remaining battery runtime in minutes during power outage

AC Line, Tel/DSL and Ethernet Surge Suppression

  • Surge suppression rating of 650 joules protects connected equipment and data from harmful power surges
  • Tel/DSL RJ11 jacks protect standard dial-up/DSL/Ethernet phone connection
  • Coaxial jacks protect CATV, broadband cable internet, satellite or broadcast antenna connection

EMI/RFI Line Noise Filtering

  • Removes electromagnetic and radio frequency interference that can disrupt or damage your equipment's performance

USB Communication Port and Free PowerAlert Software

  • HID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and Mac OS X
  • USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert

Package Includes

  • SMART1500LCDT SmartPro LCD 120V 1500VA/900W Line-Interactive UPS
  • USB cable
  • Owner’s Manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332174109
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 12A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 20A
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output Capacity (kVA) 1.5
Output Watt Capacity (Watts) 900
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) 120V (+9% / -12%)
Output Voltage Regulation (Battery Mode) 120V (±10%)
UPS Output Receptacles (Surge Suppression Only) 5 UPS outlets, 5 surge-only outlets
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (10) 5-15R
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Half Load Runtime (min.)   10 minutes (450 watts)
Expandable Runtime No
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge  RBC51  (requires 2)
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150
Overvoltage Correction   Input voltages between 129 and 147 are reduced by 15%
Undervoltage Correction   Input voltages between 92 and 108 are boosted by 18%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes
Switches Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 650
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary UPS Depth (mm) 391
Primary UPS Height (mm) 203
Primary UPS Width (mm) 146
Shipping Dimensions (hwd / in.) 11.10 x 9.00 x 19.30
Shipping Weight (lbs.) 28.00
UPS Power Module Dimensions (hwd, in.) 8 x 5.75 x 15.4
UPS Power Module Weight (kg) 12.25
UPS Power Module Weight (lbs.) 27
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   119
Battery Mode BTU / Hr. (Full Load)   867
AC Mode Efficiency Rating (100% Load) 95%
Audible Noise Less than 36 dB, front side 1m
COMMUNICATIONS
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB and cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management not supported
Communications Interface USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)
Low Voltage Transfer to Battery Power (Setpoint) 92
High Voltage Transfer to Battery Power (Setpoint) 150
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS
STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (U.S. & Canada) 3-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance