Features

2.9kW Single-Phase Monitored PDU with LX Platform Interface
Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-ft. (3.05 m) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.
 
Built-In LX Platform Network Management Interface Card
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
 
Digital Load Meter
The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.
 
Optimized for Demanding Applications
The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.
 
Versatile Installation Options
This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.
 
TAA-Compliant for GSA Schedule Purchases
The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
 
2-Year Warranty and Environmentally Responsible Design
This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.

Typical Applications

  • Give IT personnel enhanced oversight of network power conditions by remotely monitoring site power conditions and PDU load levels
  • Provide reliable distribution of AC power to supported equipment in IT, industrial and similar applications
  • Configure for 2U rack-mount installation with included hardware, making it easy to integrate with a wide range of data center and network applications

Package Includes

  • PDUMNH30 2.9kW Single-Phase Monitored PDU
  • Rack-mounting brackets
  • Cord retention brackets
  • Cable ties
  • Owner's manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332157652
PDU Type Monitored
INPUT
PDU Input Voltage 120V
Recommended Electrical Service Single-phase 30A 120V service
Maximum Input Amps 24
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L5-30P
Input Phase Single-Phase
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 2.88kW (120V) / 24A total capacity; 20A max per breakered load bank; 16A max per outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) 5-15/20R
Output Nominal Voltage 120V
Overload Protection Two 20A breakers protect 8 outlets each
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital current meter reports PDU output current in amps for 3 loading segments (Bank 1, Bank 2 and Banks 1&2 combined)
Front Panel LEDs Front panel LEDs indicate which loading segment the digital LCD current display is reporting; Bank 1 current level is reported when the Bank 1 LED is on; Bank 2 current level is reported when the Bank 2 LED is on; Total output of both banks is reported when both LEDs are on
Switches Toggle switch prompts local display of power consumption in three segments (1) Breakered load bank 1, (2) Breakered load bank 2, (3) Breakered banks 1&2 combined
PHYSICAL
Material of Construction Metal
Minimum Required Rack Depth (inches) 17.5
PDU Form Factor Horizontal (2U)
Shipping Dimensions (hwd / in.) 8.00 x 21.00 x 17.00
Shipping Weight (lbs.) 16.90
Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5
Unit Weight (lbs.) 13.8
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non-condensing
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Features

2.9kW Single-Phase Monitored PDU with LX Platform Interface
Tripp Lite's PDUMNH30 distributes and monitors single-phase 120V power to connected rack equipment in data centers, network closets, server rooms, computer rooms and other applications requiring network-grade power. Its built-in network interface allows real-time remote monitoring of voltage, frequency and load levels to prevent overloads that cause expensive downtime. It features 16 NEMA 5-15/20R outlets and a 10-ft. (3.05 m) power cord with NEMA L5-30P plug, which connects the PDU to a compatible AC power source, generator or protected UPS system.
 
Built-In LX Platform Network Management Interface Card
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
 
Digital Load Meter
The easy-to-read two-character digital LED meter displays output load levels in three segments: breakered bank 1, breakered bank 2 and total PDU output. Monitoring the individual breakered load banks helps ensure proper balance across the two output load banks. Monitoring total PDU output helps prevent PDU and supply circuit overloads that cause downtime.
 
Optimized for Demanding Applications
The all-metal housing is designed to endure in busy, demanding IT and industrial environments. The included cord retention brackets for the outlets help prevent connected equipment from becoming accidentally disconnected. Real-time clock backup maintains the time of day and date, even if the PDU is shut down and unpowered.
 
Versatile Installation Options
This server rack PDU features a 2U horizontal rack-mount form factor. Mounting flanges support installation in 2- and 4-post racks, with additional support for wall-mount and under-counter installation. Mounting ears are reversible for front- or rear-facing rack-mount installation.
 
TAA-Compliant for GSA Schedule Purchases
The PDUMNH30 monitored power distribution unit is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases.
 
2-Year Warranty and Environmentally Responsible Design
This monitored PDU comes with a 2-year limited warranty. It's manufactured in compliance with strict RoHS specifications, reflecting Tripp Lite's commitment to environmental responsibility.

Typical Applications

  • Give IT personnel enhanced oversight of network power conditions by remotely monitoring site power conditions and PDU load levels
  • Provide reliable distribution of AC power to supported equipment in IT, industrial and similar applications
  • Configure for 2U rack-mount installation with included hardware, making it easy to integrate with a wide range of data center and network applications

Package Includes

  • PDUMNH30 2.9kW Single-Phase Monitored PDU
  • Rack-mounting brackets
  • Cord retention brackets
  • Cable ties
  • Owner's manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332157652
PDU Type Monitored
INPUT
PDU Input Voltage 120V
Recommended Electrical Service Single-phase 30A 120V service
Maximum Input Amps 24
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L5-30P
Input Phase Single-Phase
Input Cord Length (ft.) 10
OUTPUT
Output Capacity Details 2.88kW (120V) / 24A total capacity; 20A max per breakered load bank; 16A max per outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) 5-15/20R
Output Nominal Voltage 120V
Overload Protection Two 20A breakers protect 8 outlets each
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital current meter reports PDU output current in amps for 3 loading segments (Bank 1, Bank 2 and Banks 1&2 combined)
Front Panel LEDs Front panel LEDs indicate which loading segment the digital LCD current display is reporting; Bank 1 current level is reported when the Bank 1 LED is on; Bank 2 current level is reported when the Bank 2 LED is on; Total output of both banks is reported when both LEDs are on
Switches Toggle switch prompts local display of power consumption in three segments (1) Breakered load bank 1, (2) Breakered load bank 2, (3) Breakered banks 1&2 combined
PHYSICAL
Material of Construction Metal
Minimum Required Rack Depth (inches) 17.5
PDU Form Factor Horizontal (2U)
Shipping Dimensions (hwd / in.) 8.00 x 21.00 x 17.00
Shipping Weight (lbs.) 16.90
Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5
Unit Weight (lbs.) 13.8
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non-condensing
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL 60950-1 (USA, Canada), FCC Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty