Product Overview
Features
- Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
- PDUBHV20 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated 2000 to 3000VA with a C20 input cable
- 2U horizontal rackmount form factor compatible with 2 or 4 post racks
- Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
- Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 5-ft. (1.52 m) C19-C20 and 2 6-ft. (1.83 m) C13-C14 interconnect cables included - user supplied alternate cabling supported)
- 6 C13 and 2 C19 outlets support critical networking loads in both Utility and UPS operating modes
- One additional C19 pass-through outlet supports UPS input power cord
- Dual input power cables support PDU connection to separate Utility and UPS power sources
- Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
- Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
- Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
- Once the new UPS is up and running with all connection s restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
Specifications
OVERVIEW
| UPC Code | 037332153913 |
| PDU Type | Hot-Swap |
INPUT
| PDU Input Voltage | 200-240V |
| Recommended Electrical Service | Works with 200-240V UPS systems with C20 compatible input cabling |
| Maximum Input Amps | 16 |
| Input Connection Type | UTILITY & UPS inputs are available from separately labeled C20 inlets, compatible with included C19-C20 interconnect cables or with compatible user-supplied cabling |
| PDU Plug Type | IEC-320 C20 |
| Input Phase | Single-Phase |
| Input Cord Length (ft.) | 6 |
OUTPUT
| Output Watt Capacity (Watts) | 3680 |
| Output Capacity Details | 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacles | (6) C13; (3) C19 |
| Output Nominal Voltage | 200-240V |
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LEDs | Lighted indicators confirm UPS and Utility switch position and operating mode |
| Switches | Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6 milliseconds |
PHYSICAL
| Material of Construction | Steel |
| Form Factors Supported | 2U rackmount in 2 or 4 post racks |
| Minimum Required Rack Depth (inches) | 9.5 |
| PDU Form Factor | Horizontal (2U) |
| Shipping Dimensions (hwd / in.) | 12.20 x 6.20 x 20.20 |
| Shipping Weight (lbs.) | 10.00 |
| Unit Dimensions (hwd / in.) | 3.42 x 17.32 x 3.03 |
| Unit Weight (lbs.) | 7.70 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +50°C (-22°F to +122°F) |
| Relative Humidity | 5-95% non condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
STANDARDS & COMPLIANCE
| Certifications | Tested to UL60950 (USA), CSA (Canada), CE (IEC60950) |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |
Features
- Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
- PDUBHV20 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated 2000 to 3000VA with a C20 input cable
- 2U horizontal rackmount form factor compatible with 2 or 4 post racks
- Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
- Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 5-ft. (1.52 m) C19-C20 and 2 6-ft. (1.83 m) C13-C14 interconnect cables included - user supplied alternate cabling supported)
- 6 C13 and 2 C19 outlets support critical networking loads in both Utility and UPS operating modes
- One additional C19 pass-through outlet supports UPS input power cord
- Dual input power cables support PDU connection to separate Utility and UPS power sources
- Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
- Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
- Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
- Once the new UPS is up and running with all connection s restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
Specifications
OVERVIEW
| UPC Code | 037332153913 |
| PDU Type | Hot-Swap |
INPUT
| PDU Input Voltage | 200-240V |
| Recommended Electrical Service | Works with 200-240V UPS systems with C20 compatible input cabling |
| Maximum Input Amps | 16 |
| Input Connection Type | UTILITY & UPS inputs are available from separately labeled C20 inlets, compatible with included C19-C20 interconnect cables or with compatible user-supplied cabling |
| PDU Plug Type | IEC-320 C20 |
| Input Phase | Single-Phase |
| Input Cord Length (ft.) | 6 |
OUTPUT
| Output Watt Capacity (Watts) | 3680 |
| Output Capacity Details | 3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V) / 16A total capacity; 16A max per C19 outlet; 12A (10A CE) max per C13 outlet |
| Frequency Compatibility | 50 / 60 Hz |
| Output Receptacles | (6) C13; (3) C19 |
| Output Nominal Voltage | 200-240V |
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LEDs | Lighted indicators confirm UPS and Utility switch position and operating mode |
| Switches | Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6 milliseconds |
PHYSICAL
| Material of Construction | Steel |
| Form Factors Supported | 2U rackmount in 2 or 4 post racks |
| Minimum Required Rack Depth (inches) | 9.5 |
| PDU Form Factor | Horizontal (2U) |
| Shipping Dimensions (hwd / in.) | 12.20 x 6.20 x 20.20 |
| Shipping Weight (lbs.) | 10.00 |
| Unit Dimensions (hwd / in.) | 3.42 x 17.32 x 3.03 |
| Unit Weight (lbs.) | 7.70 |
ENVIRONMENTAL
| Operating Temperature Range | 0C ~ 40C (32F ~ 104F) |
| Storage Temperature Range | -30°C to +50°C (-22°F to +122°F) |
| Relative Humidity | 5-95% non condensing |
| Operating Elevation (ft.) | 0-10,000 |
| Operating Elevation (m) | 0-3000 |
STANDARDS & COMPLIANCE
| Certifications | Tested to UL60950 (USA), CSA (Canada), CE (IEC60950) |
WARRANTY
| Product Warranty Period (Worldwide) | 2-year limited warranty |