Tripp-Lite PDUMH15HVATNET Switched ATS 2/2.4KW 200/240V PDU

$1,096.99
SKU:
PDUMH15HVATNET
Shipping:
Calculated at Checkout
Product Type:
Single Phase PDU

Product Overview

Features

2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy
Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-ft. (3.66 m) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.
Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding
This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.
Check Essential Functions at a Glance
A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.
Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.
 
Easy to Install Horizontally in an EIA-Standard 19 in. Rack
This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.
TAA-Compliant for GSA Schedule Purchases
The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • PDUMH15HVATNET 2-2.4kW Single-Phase ATS/Switched PDU
  • Built-in LX Platform interface
  • Configuration cable
  • (12) Plug-lock insert sleeves
  • (2) C13 to C14 power cords, 12-ft. (3.66 m)
  • Rack-mounting hardware
  • Owner's manual
TAA compliant RoHS compliant

Specifications

OVERVIEW
UPC Code 037332197504
PDU Type Auto-Transfer Switch; Switched
INPUT
PDU Input Voltage 200; 208; 220; 230; 240
Recommended Electrical Service Two single-phase 10A 200-240V circuits
Maximum Input Amps 10
Maximum Input Amps Details Agency de-rated to 12A at 200, 208, 220 & 240V; Agency de-rated to 10A at 230V
Input Connection Type Primary: C14 inlet and Secondary: C14 inlet
PDU Plug Type (2) IEC-320 C14
Input Phase Single-Phase
Input Cord Details Set of two C14 inlets and two included cordsets enable connection to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 12
OUTPUT
Output Capacity Details 2.4kW (240V), 2.3kW (230V), 2.2kW (220V), 2.08kW (208V), 2.0kW (200V) / 10A total capacity; 10A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (10) C13
Output Nominal Voltage 200-240V
Customized Load Management Receptacles   8 individually switched C13 output receptacles (2 unswitched)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports total PDU output current in amps
Front Panel LEDs 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
Switches Toggle switch near digital display enables the setting of "HI" for 220, 230 or 240V nominal applications or "LO" for 200 or 208V applications
PHYSICAL
Material of Construction Steel
Form Factors Supported 1U rackmount
Minimum Required Rack Depth (inches) 16.7
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 4.33 x 20.28 x 22.83
Shipping Weight (lbs.) 15.65
Unit Dimensions (hwd / in.) 1.71 x 17.33 x 14.45
Unit Weight (lbs.) 10.41
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
COMMUNICATIONS
PowerAlert Software LX Platform Interface: PowerAlert Device Manager
Communications Cable Micro-USB- to-USB A configuration/console Access cable
Network Monitoring Port   RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet)
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring and Reboot (included); Auto-Transfer Switching; Auto Load Shedding
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1:2007+A2:2014 (USA), CAN/CSA-C22.2 60950-1-07+A1:2011+A2:2014 (Canada), CE (EU), NOM (Mexico), EAC (Russia), EN55032:2015 and EN62040-2:2006, FCC Class A (Emissions), RoHS Compliant, TAA Compliant
Certification Details Series Number(s) AGAC7625
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warrant

Features

2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy
Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-ft. (3.66 m) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.
Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.
Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding
This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.
Check Essential Functions at a Glance
A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.
Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.
 
Easy to Install Horizontally in an EIA-Standard 19 in. Rack
This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.
TAA-Compliant for GSA Schedule Purchases
The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Package Includes

  • PDUMH15HVATNET 2-2.4kW Single-Phase ATS/Switched PDU
  • Built-in LX Platform interface
  • Configuration cable
  • (12) Plug-lock insert sleeves
  • (2) C13 to C14 power cords, 12-ft. (3.66 m)
  • Rack-mounting hardware
  • Owner's manual
TAA compliant RoHS compliant

Specifications

OVERVIEW
UPC Code 037332197504
PDU Type Auto-Transfer Switch; Switched
INPUT
PDU Input Voltage 200; 208; 220; 230; 240
Recommended Electrical Service Two single-phase 10A 200-240V circuits
Maximum Input Amps 10
Maximum Input Amps Details Agency de-rated to 12A at 200, 208, 220 & 240V; Agency de-rated to 10A at 230V
Input Connection Type Primary: C14 inlet and Secondary: C14 inlet
PDU Plug Type (2) IEC-320 C14
Input Phase Single-Phase
Input Cord Details Set of two C14 inlets and two included cordsets enable connection to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 12
OUTPUT
Output Capacity Details 2.4kW (240V), 2.3kW (230V), 2.2kW (220V), 2.08kW (208V), 2.0kW (200V) / 10A total capacity; 10A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (10) C13
Output Nominal Voltage 200-240V
Customized Load Management Receptacles   8 individually switched C13 output receptacles (2 unswitched)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports total PDU output current in amps
Front Panel LEDs 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
Switches Toggle switch near digital display enables the setting of "HI" for 220, 230 or 240V nominal applications or "LO" for 200 or 208V applications
PHYSICAL
Material of Construction Steel
Form Factors Supported 1U rackmount
Minimum Required Rack Depth (inches) 16.7
PDU Form Factor Horizontal (1U)
Shipping Dimensions (hwd / in.) 4.33 x 20.28 x 22.83
Shipping Weight (lbs.) 15.65
Unit Dimensions (hwd / in.) 1.71 x 17.33 x 14.45
Unit Weight (lbs.) 10.41
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5-95% non condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
COMMUNICATIONS
PowerAlert Software LX Platform Interface: PowerAlert Device Manager
Communications Cable Micro-USB- to-USB A configuration/console Access cable
Network Monitoring Port   RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems
Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet)
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring and Reboot (included); Auto-Transfer Switching; Auto Load Shedding
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1:2007+A2:2014 (USA), CAN/CSA-C22.2 60950-1-07+A1:2011+A2:2014 (Canada), CE (EU), NOM (Mexico), EAC (Russia), EN55032:2015 and EN62040-2:2006, FCC Class A (Emissions), RoHS Compliant, TAA Compliant
Certification Details Series Number(s) AGAC7625
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warrant