Tripp-Lite PDU3EVN6L2120 5.8kW 208/120V 3PH Monitored PDU

$1,094.99
SKU:
PDU3EVN6L2120
Shipping:
Calculated at Checkout
Product Type:
3-Phase PDU

Product Overview

Features

3-Phase 0U PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A 6-ft. (1.83 m) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.
 
45 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks—three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.
 
Built-In GbE-Capable Network Management Card Allows Remote Access 24/7
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
 
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
 
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.
 
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
 
2-Year Warranty
The PDU3EVN6L2120 is backed by a 2-year warranty, ensuring reliability and performance.

Typical Applications

  • Power a major data center with hundreds of server racks running mission-critical applications
  • Monitor power loads from various computers, switches, servers and other networking equipment
  • Distribute power to a computer network in a large commercial or industrial facility

Package Includes

  • PDU3EVN6L2120 5.8kW 3-Phase Monitored PDU
  • Built-in LX Platform interface
  • Configuration cable
  • (42) Plug-lock insert sleeves
  • Rack-mounting hardware
  • Spare mounting buttons
  • PDUMVROTATEBRKT mounting bracket accessory
  • Owner’s manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332206787
PDU Type Monitored
INPUT
PDU Input Voltage 208V
Recommended Electrical Service Three-phase 20A 208V service
Maximum Input Amps 16
PDU Plug Type NEMA L21-20P
Input Phase 3-Phase
Input Cord Length (ft.) 6
OUTPUT
Output Capacity Details 5.7kW (208/120V) total capacity; 9.2A (208V) max per output phase (L1-L2, L2-L3, L3-L1) / 16A (120V) max per output phase (L1, L2, L3)
Frequency Compatibility 50 / 60 Hz
Output Receptacle Details 5-15/20R outlets provide 120V output; C13 and C19 outlets provide 208V output
Output Receptacles (3) 5-15/20R; (36) C13; (6) C19
Output Nominal Voltage 208/120V
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments Supports monitoring of input current per phase (L1, L2, L3) and output current for each output load bank (B1-B6); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 feeds black C13/C19 outlets (B1); L2-L3 feeds dark-gray C13/C19 outlets (B2); L3-L1 feeds light-gray C13/C19 outlets (B3); L1-N feeds black 5-20R outlet (B4); L2-N feeds dark-gray 5-20R outlet (B5); L3-N feeds light-gray 5-20R outlet (B6)
Front Panel LCD Display Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / in.) 7.09 x 9.65 x 75.87
Unit Dimensions (hwd / in.) 70 x 2.17 x 2.52
Unit Weight (lbs.) 13.50
ENVIRONMENTAL
Operating Temperature Range 0C ~ 50C (32F ~ 122F)
Storage Temperature Range -30°C to +60°C (-22°F to +140°F)
Relative Humidity 5 to 95% non-condensing
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform network interface
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014 (Canada), FCC CLASS A PART 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty

Features

3-Phase 0U PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, this monitored power distribution unit provides real-time remote monitoring of voltage and load levels via built-in network connection. A 6-ft. (1.83 m) cord with NEMA L21-20P input plug connects the 208V 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the Tripp Lite vertical PDU continues to perform at its best.
 
45 Outlets Dispense AC Power to Connected Equipment
During normal operation, 36 C13 (208V), six C19 (208V) and three NEMA 5-15/20R (120V) outlets distribute AC power to rack equipment. The outlets are split into six individually monitored load banks—three banks containing two C19 and 12 C13 outlets and three of one 5-15/20R outlet each. Three LEDs monitor load conditions for each bank. Plug-lock insert sleeves for the C13 and C19 outlets are included to prevent connected cables from becoming accidentally dislodged.
 
Built-In GbE-Capable Network Management Card Allows Remote Access 24/7
The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.
 
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 0U PDU via mobile device. If an EnviroSense2 module is connected to the 3-phase PDU, the LCD also displays status and environmental data, such as temperature and humidity.
 
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch (178 cm) 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 208V 3-phase PDU with outlets facing the rear for better airflow or equipment access.
 
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6L2120 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
 
2-Year Warranty
The PDU3EVN6L2120 is backed by a 2-year warranty, ensuring reliability and performance.

Typical Applications

  • Power a major data center with hundreds of server racks running mission-critical applications
  • Monitor power loads from various computers, switches, servers and other networking equipment
  • Distribute power to a computer network in a large commercial or industrial facility

Package Includes

  • PDU3EVN6L2120 5.8kW 3-Phase Monitored PDU
  • Built-in LX Platform interface
  • Configuration cable
  • (42) Plug-lock insert sleeves
  • Rack-mounting hardware
  • Spare mounting buttons
  • PDUMVROTATEBRKT mounting bracket accessory
  • Owner’s manual
TAA compliant Cisco compatible RoHS compliant

Specifications

OVERVIEW
UPC Code 037332206787
PDU Type Monitored
INPUT
PDU Input Voltage 208V
Recommended Electrical Service Three-phase 20A 208V service
Maximum Input Amps 16
PDU Plug Type NEMA L21-20P
Input Phase 3-Phase
Input Cord Length (ft.) 6
OUTPUT
Output Capacity Details 5.7kW (208/120V) total capacity; 9.2A (208V) max per output phase (L1-L2, L2-L3, L3-L1) / 16A (120V) max per output phase (L1, L2, L3)
Frequency Compatibility 50 / 60 Hz
Output Receptacle Details 5-15/20R outlets provide 120V output; C13 and C19 outlets provide 208V output
Output Receptacles (3) 5-15/20R; (36) C13; (6) C19
Output Nominal Voltage 208/120V
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments Supports monitoring of input current per phase (L1, L2, L3) and output current for each output load bank (B1-B6); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 feeds black C13/C19 outlets (B1); L2-L3 feeds dark-gray C13/C19 outlets (B2); L3-L1 feeds light-gray C13/C19 outlets (B3); L1-N feeds black 5-20R outlet (B4); L2-N feeds dark-gray 5-20R outlet (B5); L3-N feeds light-gray 5-20R outlet (B6)
Front Panel LCD Display Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device)
Current Measurement Accuracy (Amps) +/-1%
Voltage Measurement Accuracy (Volts) +/-1%
Power Measurement Accuracy (Watts) +/-1%
PHYSICAL
Material of Construction Metal
Form Factors Supported Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-mount compatible racks
PDU Form Factor Vertical (0U)
Shipping Dimensions (hwd / in.) 7.09 x 9.65 x 75.87
Unit Dimensions (hwd / in.) 70 x 2.17 x 2.52
Unit Weight (lbs.) 13.50
ENVIRONMENTAL
Operating Temperature Range 0C ~ 50C (32F ~ 122F)
Storage Temperature Range -30°C to +60°C (-22°F to +140°F)
Relative Humidity 5 to 95% non-condensing
COMMUNICATIONS
SNMP Compatibility Pre-installed LX platform network interface
FEATURES & SPECIFICATIONS
High Availability PDU Features   Auto Probe Monitoring (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014 (Canada), FCC CLASS A PART 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty