null

Tripp-Lite OMNI1000ISO OmniSmart 120V 1000VA 700W Line-Interactive UPS

MSRP: $744.89
$665.99
(You save $78.90 )
SKU:
OMNI1000ISO
Shipping:
Calculated at Checkout
Product Type:
Single Phase UPS
Type:
Line-Interactive

Product Overview

Overview

Tripp Lite's OMNI1000ISO offers complete UPS protection with built-in line-interactive voltage regulation, intelligent monitoring and unattended shutdown capability. Built-in isolation transformer with Faraday shield offers full isolation and complete common mode noise rejection. 1000VA power-handling capacity supports point-of-sale applications, computers, internetworking equipment and home theater systems during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, reserving battery power for use during complete power failures. USB communications port works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Features

  • 1000VA line-interactive UPS with Faraday-shielded, low-impedance isolation transformer delivers full isolation from potential damage and performance problems
  • Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal-reference ground, reducing data errors and audio/video distortion
  • Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working through low voltage (brownouts) as low as 81V and overvoltages as high as 143V without consuming battery power
  • Supports loads up to 1000VA/700W
  • Half-load runtime of 24 min. (500VA/350W); full load runtime of 8 min. (1000VA/700W)
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery low/replace
  • Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
  • USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
  • Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance U.S., Canada, and Puerto Rico only) safeguards connected equipment against damage
  • SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
  • SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1
  • INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
  • 6 UPS-supported AC outlets; 6-ft. cord
  • Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment

Package Includes

  • OMNI1000ISO UPS System
  • USB cable
  • Instruction manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332126931
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 7.6A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Capacity (kVA) 1
Output Watt Capacity (Watts) 700
Output Capacity Details 5.8A @ 120V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds
Power Factor   0.7
Nominal Voltage Details 120V in line mode and 115V battery
Frequency Compatibility 60 Hz
Frequency Compatibility Details Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Output Voltage Regulation (Line Mode) -18%, +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (6) 5-15R
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)   8 min. (700w)
Half Load Runtime (min.)   24 min. (350w)
Expandable Runtime No
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge  RBC53 
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
Overvoltage Correction   Input voltages between 128 and 143V are reduced by 9%
Undervoltage Correction   Input voltages between 96 and 107V are boosted by 10%
Severe Undervoltage Correction Input voltages between 85 and 95V are boosted by 20%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
ISOLATION
Output Isolation Transformer   Professional grade load isolation transformer
Surge Voltage Withstand Capability ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
Surge Voltage Attenuation N-G 2000:1, L-G 240:1, L-N 100:1
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 510
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  - tower mounting kit)
Primary UPS Depth (mm) 234
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / in.) 16.90 x 13.50 x 11.30
Shipping Weight (lbs.) 46.10
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, in.) 12.8 x 7.5 x 9.2
UPS Power Module Weight (kg) 16.51
UPS Power Module Weight (lbs.) 36.4
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) 91%
AC Economy Mode Efficiency Rating (100% Load) 0.91
Operating Elevation (ft.) 6561 ft. (2000 m) above sea level
COMMUNICATIONS
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Insertion Loss   65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
Network Management Card Description Network management not supported
Communications Interface USB
LINE / BATTERY TRANSFER
Transfer Time   6 milliseconds typical (10 milliseconds max)
Low Voltage Transfer to Battery Power (Setpoint) 81
High Voltage Transfer to Battery Power (Setpoint) 143
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Hot swappable batteries; Surge/noise protection
STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $200,000 Ultimate Lifetime Insurance 

Overview

Tripp Lite's OMNI1000ISO offers complete UPS protection with built-in line-interactive voltage regulation, intelligent monitoring and unattended shutdown capability. Built-in isolation transformer with Faraday shield offers full isolation and complete common mode noise rejection. 1000VA power-handling capacity supports point-of-sale applications, computers, internetworking equipment and home theater systems during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, reserving battery power for use during complete power failures. USB communications port works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Features

  • 1000VA line-interactive UPS with Faraday-shielded, low-impedance isolation transformer delivers full isolation from potential damage and performance problems
  • Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal-reference ground, reducing data errors and audio/video distortion
  • Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working through low voltage (brownouts) as low as 81V and overvoltages as high as 143V without consuming battery power
  • Supports loads up to 1000VA/700W
  • Half-load runtime of 24 min. (500VA/350W); full load runtime of 8 min. (1000VA/700W)
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery low/replace
  • Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
  • USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
  • Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance U.S., Canada, and Puerto Rico only) safeguards connected equipment against damage
  • SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
  • SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1
  • INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
  • 6 UPS-supported AC outlets; 6-ft. cord
  • Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment

Package Includes

  • OMNI1000ISO UPS System
  • USB cable
  • Instruction manual
RoHS compliant

Specifications

OVERVIEW
UPC Code 037332126931
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 7.6A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Capacity (kVA) 1
Output Watt Capacity (Watts) 700
Output Capacity Details 5.8A @ 120V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds
Power Factor   0.7
Nominal Voltage Details 120V in line mode and 115V battery
Frequency Compatibility 60 Hz
Frequency Compatibility Details Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Output Voltage Regulation (Line Mode) -18%, +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (6) 5-15R
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.)   8 min. (700w)
Half Load Runtime (min.)   24 min. (350w)
Expandable Runtime No
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge  RBC53 
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
Overvoltage Correction   Input voltages between 128 and 143V are reduced by 9%
Undervoltage Correction   Input voltages between 96 and 107V are boosted by 10%
Severe Undervoltage Correction Input voltages between 85 and 95V are boosted by 20%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
ISOLATION
Output Isolation Transformer   Professional grade load isolation transformer
Surge Voltage Withstand Capability ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
Surge Voltage Attenuation N-G 2000:1, L-G 240:1, L-N 100:1
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 510
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Tower
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount ( UPSWM  - tower mounting kit)
Primary UPS Depth (mm) 234
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / in.) 16.90 x 13.50 x 11.30
Shipping Weight (lbs.) 46.10
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, in.) 12.8 x 7.5 x 9.2
UPS Power Module Weight (kg) 16.51
UPS Power Module Weight (lbs.) 36.4
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) 91%
AC Economy Mode Efficiency Rating (100% Load) 0.91
Operating Elevation (ft.) 6561 ft. (2000 m) above sea level
COMMUNICATIONS
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at https://www.tripplite.com/poweralert
Communications Cable USB cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Insertion Loss   65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
Network Management Card Description Network management not supported
Communications Interface USB
LINE / BATTERY TRANSFER
Transfer Time   6 milliseconds typical (10 milliseconds max)
Low Voltage Transfer to Battery Power (Setpoint) 81
High Voltage Transfer to Battery Power (Setpoint) 143
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Hot swappable batteries; Surge/noise protection
STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $200,000 Ultimate Lifetime Insurance