null
Happy Thanksgiving! We’ll be closed and

SICK 2107898 YF2A55-020C1BM2A55 Fieldbus, shielded, CANopen, DeviceNet™, 2 m, 4-wire, PUR, halogen-free

$196.00
SKU:
2107898
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

SICK 2107898 YF2A55-020C1BM2A55 Fieldbus, shielded, CANopen, DeviceNet™.

Technical specifications

  • Connection type head A: Female connector, M12, 5-pin, straight, A-coded
  • Connection type head B: Male connector, M12, 5-pin, straight, A-coded
  • Locking plug connector: Screw connection
  • Connector material: TPU
  • Connector color: Black
  • Locking nut material: Stainless steel (V4A/1.4404)
  • Seal material: FKM
  • Tightening torque: 0.6 Nm
  • Width across flats: 13
  • Cable: 2 m, 4-wire, PUR, halogen-free
  • Jacket material: PUR, halogen-free
  • Jacket color: Violet
  • Cable diameter: 6.9 mm
  • Conductor cross section: 2 x 0.25 mm² + 2 x 0.34 mm²
  • Shielding: Shielded
  • Flexible use: > 10 x cable diameter
  • Stationary position: > 5 x cable diameter
  • Drag chain operation: > 10 x cable diameter
  • Bending cycles: 1,000,000
  • Nominal voltage, cable: 300 V AC
  • Test voltage, cable: 2,000 V AC
  • Rated impulse voltage: 1.5 kV
  • Current loading: 4 A
  • Traversing speed: 3 m/s
  • Travelling distance: 5 m
  • Acceleration: ≤ 5 m/s²
  • Signal type: Fieldbus, CANopen, DeviceNet™
  • Transmission characteristics: CANopen, DeviceNet™
  • Application: Drag chain operation; Zones with oils and lubricants
  • UL File No.: E335179
  • Enclosure rating: IP65 / IP66K / IP67
  • Flexible use: –30 °C ... +70 °C
  • Stationary position: –40 °C ... +80 °C
  • Head: –25 °C ... +85 °C
  • Contamination rating: 3
  • Insulation resistance: 100 MΩ
  • Overvoltage category: III
  • Specific insulation resistance: 30 mΩ
  • Thermal resistance, piping: Flame retardant acc. to UL 1581 Section 1090, Section 1100 (FT2) / IEC 60332-1-2

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • China RoHS: ✔
  • China Compulsory Product Certification (CCC) exempt: ✔
  • cULus certificate: ✔

Download SICK product specification sheet (PDF)