Description
SICK 2093098 SP2-2100 System plugs and extension modules.
Features
- Compatible devices: deTec4, deTem4, deTem4 A/P
- Function range: SP2
- System connection: Plug, M12, 5-pin
- Extension connection: Female connector M12, 5-pin
- IO-Link possible on the extension connection: ✔
- Configuration method: DIP switch
- Items supplied: System plug
Functions
- Protective operation: ✔
- Automatic calibration of the protective field width: ✔
- Restart interlock: ✔
- External device monitoring (EDM): ✔
- Application diagnostic output (ADO): ✔
- Cascading: ✔
- Smart presence detection: ✔
- Reduced resolution: ✔
- Dynamic protective field width during operation: ✔
- Sender with reduced scanning range: ✔
- 2-signal muting: ✔
- Smart Box Detection: ✔
Interfaces
- PIN assignment: See table in “Pin assignment” graphic
- System connection: Plug, M12, 5-pin
- Length of cable: 200 mm
- Cable diameter: 5 mm
- Extension connection: Female connector M12, 5-pin
- Length of cable: 150 mm
Electronics
- Protection class: III (IEC 61140)
- Supply voltage VS: 24 V DC (19.2 V ... 28.8 V)
- Ripple: ≤ 10 %
Ambient data
- Ambient operating temperature: –30 °C ... +55 °C
- Storage temperature: –30 °C ... +70 °C
- Air humidity: 15 % ... 95 %, Non-condensing
- Vibration resistance: 5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
- Shock resistance: 10 g, 16 ms (IEC 60068-2-27)
Certificates
- EU declaration of conformity: ✔