Description
SICK 1115258 V3DU3-008BM21A Machine vision.
Features
- Technology: 3D laser triangulation
- Streaming: ✔
- Pre-calibrated: ✔
- Shutter technology: Global-Shutter
- Working range: 99 mm ... 147.7 mm
- Example field of view: 70 mm x 30 mm
- Exposure mode: Linear; HDR
- Illumination: Integrated
- Illumination color: Blue, laser, Visible, 450 nm, ± 15 nm
- Laser class: 2 (EN 60825-1:2014+A11:2021; IEC 60825-1:2014, Complies with the FDA performance requirements for laser products except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice 56 dated May 8, 2019.)
- Data synchronization: Free running, encoder triggered, external triggering
- 3D measurement: ✔
- Scatter measurement: ✔
- Reflectance measurement: ✔
- Ambient light suppression: ✔ 1)
- Scheimpflug adapter, integrated: ✔
- Width at minimum operating distance: 60 mm
- Width at maximum operating distance: 85 mm
- Maximum height range: 48.7 mm
- Task: Detecting - Standard objects; Detecting - Level; Measuring - Dimension, contour and volume; Monitoring and controlling - Quality; Determining position - 3D position determination
1) Blue bandpass filter.
Mechanics/electronics
- Connection type: Voltage – I/O: M12, 17-pin male connector; Gigabit Ethernet: M12, 8-pin socket, X-coded
- Connector material: M12: Nickel-coated brass
- Supply voltage: 24 V DC, ± 10 %
- Ripple: < 5 Vpp
- Power consumption: ≤ 12 W
- Current consumption: ≤ 1.5 A
- Enclosure rating: IP65; IP67
- Protection class: III
- Housing material: Aluminum
- Housing color: Blue
- Window material: Float glass, anti-reflective coated
- Weight (technical data): 1.2 kg
- Dimensions (L x W x H): 159 mm x 65 mm x 104 mm
Performance
- Image sensor: CMOS sensor from SICK with ROCC technology, M30
- Scan/frame rate: 46,000 3D profiles/s, In reduced ROI; 7,000 3D profiles/s, full format
- Data points/profile: 3,200
- Repeatability: 1.6 µm, for Z 1)
- Typical resolution: Z resolution (height): 3.5 µm ... 7 µm, X resolution (width): 26 µm ... 37 µm
1) Height values measured for different positions in the field of view. 20 measurements are performed at each position. The repeatability value is the 3-fold of the standard deviation (3 σ) for all measurements at all positions.
Interfaces
- Ethernet: ✔ , UDP/IP
- Remark: GigE Vision Standard
- Data transmission rate: ≤ 1 Gbit/s
- Configuration software: Stream Setup
- Operating system: Windows 10
- Application programming interface (API): GenAPI, GenTL, Proprietary SICK GenIStream
- Inputs/outputs: 4 x HIGH = 10 V ... 28.8 V, configurable
- Encoder interface: RS-422 5 V, 2 x HTL single-ended
Ambient data
- Shock load: 15 g, 3 cycles per axis
- Vibration load: 5 g, 10 Hz ... 150 Hz (EN 60068-2-6)
- Ambient operating temperature: 0 °C ... +40 °C 1)
- Storage temperature: –30 °C ... +70 °C 1)
1) Non-condensing.
Certificates
- EU declaration of conformity: ✔
- UK declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- China RoHS: ✔
- Optical radiation safety (GB 44703:2024) declaration of manufacturer (low risk): ✔
- Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔
- GigE Vision: ✔
- GenICam: ✔