SICK 1106098 GSE2FS-P1161 Through-beam photoelectric sensor.

Features

  • Functional principle: Through-beam photoelectric sensor
  • Dimensions (W x H x D): 4.5 mm x 21 mm x 11 mm
  • Housing design (light emission): Rectangular
  • Minimum detectable object (MDO): 1.8 mm
  • Sensing range max.: 0 mm ... 1,300 mm
  • Sensing range: 0 mm ... 1,000 mm
  • Type of light: Visible red light
  • Light source: PinPoint LED 1)
  • Light spot size (distance): Ø 100 mm (1,000 mm)
  • Wave length: 660 nm
  • Adjustment: None

1) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

  • Supply voltage UB: 10 V DC ... 30 V DC
  • Ripple: < 5 Vpp1)
  • Current consumption: 20 mA 2)
  • Switching output: PNP
  • Switching mode: Light switching
  • Output current Imax.: ≤ 50 mA
  • Response time: < 0.625 ms 3)
  • Switching frequency: 800 Hz 4)
  • Connection type: Cable, 3-wire, 2 m 5)
  • Cable material: Plastic, PVC
  • Cable diameter: Ø 2.3 mm
  • Circuit protection: A 6); C 7); D 8)
  • Weight (technical data): 13 g
  • Housing material: Plastic, VISTAL®
  • Optics material: Plastic, MABS
  • Enclosure rating: IP67
  • Ambient operating temperature: –20 °C ... +50 °C
  • Ambient temperature, storage: –40 °C ... +70 °C
  • UL File No.: NRKH.E348498 & NRKH7.E348498
  • Repeatability (Ta not constant): 0.1 mm

1) May not fall below or exceed UV tolerances.

2) Without load.

3) Signal transit time with resistive load.

4) With light/dark ratio 1:1.

5) Do not bend below 0 °C.

6) A = VS connections reverse-polarity protected.

7) C = interference suppression.

8) D = outputs overcurrent and short-circuit protected.

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • ACMA declaration of conformity: ✔
  • Moroccan declaration of conformity: ✔
  • China RoHS: ✔
  • China Compulsory Product Certification (CCC) exempt: ✔
  • cRUus certificate: ✔