Description
SICK 1104983 DBS36E-S3RN00020 Incremental encoders.
Safety-related parameters
- MTTFD (mean time to dangerous failure): 600 years (EN ISO 13849-1) 1)
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Performance
- Pulses per revolution: 20
- Measuring step: 90°, electric/pulses per revolution
- Measuring step deviation: ± 18° / pulses per revolution
- Error limits: ± 54° / pulses per revolution
- Duty cycle: ≤ 0.5 ± 5 %
Interfaces
- Communication interface: Incremental
- Communication Interface detail: Open Collector
- Number of signal channels: 3 channel
- Initialization time: < 3 ms
- Output frequency: ≤ 300 kHz
- Load current: ≤ 30 mA
- Power consumption: ≤ 0.5 W (without load)
Electronics
- Connection type: Cable, 5-wire, universal, 10 m
- Supply voltage: 7 ... 30 V
- Reference signal, number: 1
- Reference signal, position: 90°, electric, logically gated with A and B
- Reverse polarity protection: ✔
- Short-circuit protection of the outputs: ✔ 1)
1) The short-circuit rating is only given if Us and GND are connected correctly.
Mechanics
- Mechanical design: Solid shaft, face mount flange
- Shaft diameter: 6 mm; With flat
- Shaft length: 12 mm
- Weight (technical data): + 150 g (with connecting cable)
- Shaft material: Stainless steel
- Flange material: Aluminum
- Housing material: Aluminum
- Material, cable: PVC
- Start up torque: + 0.5 Ncm (+20 °C)
- Operating torque: 0.4 Ncm (+20 °C)
- Permissible shaft loading: 40 N (radial) 1); 20 N (axial)
- Operating speed: 6,000 min⁻¹ 2)
- Maximum operating speed: ≤ 8,000 min⁻¹ 3)
- Moment of inertia of the rotor: 0.6 gcm²
- Bearing lifetime: 2 x 10^9 revolutions
- Angular acceleration: ≤ 500,000 rad/s²
1) Higher values are possible using limited bearing life.
2) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.
3) No permanent operation. Decreasing signal quality.
Ambient data
- EMC: According to EN 61000-6-2 and EN 61000-6-3 (class A)
- Enclosure rating: IP65
- Permissible relative humidity: 90 % (Condensation not permitted)
- Operating temperature range: –20 °C ... +85 °C, –35 °C ... +95 °C on request
- Storage temperature range: –40 °C ... +100 °C, without package
- Resistance to shocks: 100 g, 6 ms (EN 60068-2-27)
- Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
Certificates
- EU declaration of conformity: ✔
- UK declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- China RoHS: ✔
- cRUus certificate: ✔
- Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔
Image is representative and may differ from the supplied item.