SICK 1068468 LFP0450-A4NMB Level sensors.

Features

  • Medium: Fluids
  • Measurement: Switch, Continuous
  • Design: Standard amplifier
  • Probe type: Rod probe
  • Probe length: 450 mm
  • Process pressure: –1 bar ... 10 bar
  • Process temperature: –20 °C ... +100 °C

Performance

  • Accuracy of sensor element: ± 5 mm
  • Reproducibility: ≤ 2 mm
  • Resolution: 1 mm
  • Response time: 400 ms 1)
  • Dielectricity constant: ≥ 5 for rod probe / cable probe; ≥ 1.8 with coaxial tube
  • Conductivity: No limitation
  • Maximum level change: ≤ 500 mm/s
  • Deactivated area at process connection: 25 mm 2)
  • Deactivated area at end of probe: ≥ 10 mm 3)
  • MTTF: 194.3 years (EN ISO 13849-1)
  • Display: ✔

1) Dependent on measuring mode (high speed < 400 ms, high accuracy < 2,800 ms).

2) With parameterized container with water under reference conditions, otherwise 40 mm.

3) With water under reference conditions.

Electronics

  • Communication interface: IO-Link
  • Supply voltage: 12 V DC ... 30 V DC 1)
  • Power consumption: ≤ 75 mA at 24 V DC without output load
  • Initialization time: ≤ 2 s
  • Protection class: III
  • Connection type: Round connector M12 x 1, 5-pin
  • Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
  • Output load: 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V; 4 mA ... 20 mA < 400 Ohm at Uv > 12 V; 0 V ... 10 V > 750 Ohm at Uv ≥ 14 V
  • Hysteresis: ≥ 2 mm 2)
  • Output current: < 100 mA
  • Inductive load: < 1 H
  • Capacitive load: ≤ 100 nF
  • Enclosure rating: IP67 (EN 60529)
  • Temperature drift: < 0.1 mm/K
  • Lower signal level: 3.8 mA ... 4 mA, 0 V
  • Upper signal level: 20 mA ... 20.5 mA, 10.5 V
  • EMC: EN 61326-2-3, 2014/30/EU

1) All connections are polarity protected. All outputs are overload and short-circuit protected.

2) Freely adjustable.

Mechanics

  • Wetted parts: Stainless steel 1.4404 / 316L; PTFE; FKM
  • Process connection: G ¾ A
  • Housing material: Plastic PBT
  • Max. probe load: ≤ 6 Nm

Ambient data

  • Ambient operating temperature: –20 °C ... +60 °C
  • Ambient temperature, storage: –40 °C ... +80 °C
  • Outdoor use: Only with weather hood

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • ACMA declaration of conformity: ✔
  • Moroccan declaration of conformity: ✔
  • China RoHS: ✔
  • China Compulsory Product Certification (CCC) exempt: ✔
  • cULus certificate: ✔
  • IO-Link certificate: ✔
  • Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔