null

SICK 1054862 MPS-032THTP0 Cylinder sensors, 32 mm, Cable with M8 male connector, 4-pin, 0.3 m, PUR, 15 V DC ... 30 V DC

$389.00
SKU:
1054862
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

SICK 1054862 MPS-032THTP0 Cylinder sensors.

Features

  • Cylinder type: T-slot
  • Cylinder types with adapter: Round body cylinder; Profile cylinders and tie-rod cylinders; Dovetail groove cylinder
  • Measuring range: 32 mm 1)
  • Housing length: 45 mm
  • Output function: Analog
  • Electrical wiring: DC 4-wire
  • Analog output (voltage): 0 V ... 10 V 2)
  • Analog output (current): 4 mA ... 20 mA 2)
  • Enclosure rating: IP67 3)
  • Teach-in control panel: Teaching in analog outputs; Resetting the measuring range to factory settings

1) ± 1 mm.

2) The sensor only activates the wired output.

3) According to EN 60529.

Mechanics/electronics

  • Supply voltage: 15 V DC ... 30 V DC
  • Power consumption: 22 mA, without load
  • Max. load resistance: ≤ 500 Ω Power Output, at 24 V
  • Min. load resistance: ≥ 2 kΩ 1)
  • Protection class: III
  • Time delay before availability: 1.5 s
  • Required magnetic field sensitivity, typ.: 2 mT ... 15 mT
  • Resolution, typ.: 0.03 % FSR (max. ≥ 0.05 mm) 2)
  • Linearity error, typ.: 0.3 mm 3)
  • Repeat accuracy, typ.: 0.06 % FSR (≥ 0.1 mm) 4)
  • Sampling rate, typ.: 1 ms 5)
  • Reverse polarity protection: Yes
  • Short-circuit protection: Yes
  • Status indicator LED: Yes
  • Teach-in: Yes
  • Ambient operating temperature: –20 °C ... +70 °C
  • Shock and vibration resistance: 30 g, 11 ms / 10 ... 55 Hz, 1 mm
  • EMC: According to EN 60947-5-7 6)
  • Connection type: Cable with M8 male connector, 4-pin, 0.3 m
  • Deep-freeze property: Do not bend below 0 °C
  • Conductor cross section: 0.08 mm²
  • Cable diameter: Ø 2.6 mm
  • Bending radius: With fixed installation > 5 x cable diameter
  • Cable outlet: Axial
  • Housing: Plastic
  • Cable: PUR
  • UL File No.: NRKH.E181493 & NRKH7.E181493

1) Voltage output.

2) FSR: Full Scale Range; max. measuring range.

3) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.

4) At 25 ° C, repeatability magnet movement in one direction.

5) Only in standard mode, not in IO-Link mode.

6) The analog measured value can deviate for up to 100 ms under transient conditions.

Safety-related parameters

  • MTTFD: 387 years
  • DCavg: 0 %
  • TM (mission time): 20 years

Certificates

  • EU declaration of conformity: ✔
  • UK declaration of conformity: ✔
  • ACMA declaration of conformity: ✔
  • Moroccan declaration of conformity: ✔
  • China RoHS: ✔
  • China Compulsory Product Certification (CCC) exempt: ✔
  • cULus certificate: ✔

Download SICK product specification sheet (PDF)