Description
SICK 1050158 IVC-3D51113 3D machine vision.
Features
- Task: Presence inspection; Quality inspection; Measuring, 3D
- Technology: 3D line scanning
- Product category: Programmable
- Working distance: 259 mm ... 398 mm 1)
- Example field of view: 100 mm x 200 mm
- Internal lighting: Laser, Visible, Red, 658 nm, ± 15 nm
- Laser class: 2 (IEC 60825-1:2014, EN 60825-1:2014)
- Factory calibrated: ✔
- Width at minimum operating distance: 179 mm
- Width at maximum operating distance: 255 mm
- Maximum height range: 139 mm
- Imaging angle: 61°
- Offline support: Emulator
1) The specified values are valid for single device installations. Please see operating instructions for details.
Mechanics/electronics
- Connection type: M12, 4-pin female connector, D-coded (Ethernet); M12, 8-pin female connector (RS-485); M12, 8-pin male connector, A-coded (voltage supply, I/O); M12, 5-pin male (Encoder)
- Connector material: Stainless steel
- Supply voltage: 24 V DC, ± 20 %
- Ripple: < 5 Vpp
- Current consumption: < 1 A, without output load
- Enclosure rating: IP67
- Protection class: III
- Housing material: Stainless steel
- Window material: PMMA
- Weight (technical data): 5.5 kg
- Dimensions (L x W x H): 311 mm x 103 mm x 187 mm
Performance
- Image sensor: CMOS
- Processor: 800 MHz
- Scan/frame rate: 5,000 3D profiles/s
- Memory: 128 MB RAM, 16 MB flash
- Typical height resolution: 0.05 mm
- 3D profile resolution: 2,048 points
Interfaces
- Ethernet: ✔ , TCP/IP, UDP/IP
- Remark: Including OPC server
- Data transmission rate: 10/100 MBit/s
- EtherNet/IP™: ✔
- Serial: ✔ , RS-422, RS-485
- Function: Encoder (RS-422)
- Data transmission rate: Maximum encoder frequency: 2 MHz
- Operator interfaces: Application-specific user interfaces can be set up as stand-alone web pages. The integrated OPC server supports data exchange with SCADA systems, for example.
- Configuration software: IVC Studio
- Data storage and retrieval: Images and data can be stored to and retrieved from flash and external FTP servers
- Digital input: 3 program controlled inputs (1 trigger input), HIGH = 10 V ... 28.8 V
- Digital output: 3 programmable type B digital outputs, Max. output current 100 mA, trigger output
- Encoder interface: RS-422
- Maximum encoder frequency: 2 MHz
Ambient data
- Shock load: 15 g, 3 x 6 directions
- Vibration load: 5 g, 58 Hz ... 150 Hz
- Ambient operating temperature: 0 °C ... +40 °C
- Storage temperature: –20 °C ... +70 °C
Certificates
- EU declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- China RoHS: ✔
Image is representative and may differ from the supplied item.