Description
SICK 1036503 ARS60-AAA01000 Absolute encoders.
Safety-related parameters
- MTTFD (mean time to dangerous failure): 300 years (EN ISO 13849-1) 1)
1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.
Performance
- Number of steps per revolution (max. resolution): 1,000
- Measuring step: 360° /number of steps
- Measuring step deviation: 0.016° non-binary number of steps
- Error limits G: 0.046° (non-binary number of steps) 1)
- Repeatability standard deviation σr: 0.005° 2)
1) In accordance with DIN ISO 1319-1, position of the upper and lower error limit depends on the installation situation, specified value refers to a symmetrical position, i.e. deviation in upper and lower direction is the same.
2) In accordance with DIN ISO 55350-13; 68.3% of the measured values are inside the specified area.
Interfaces
- Communication interface: SSI
- Initialization time: 80 ms 1)
- Code type: Gray
- Code sequence parameter adjustable: CW (clockwise) increasing when viewing the clockwise rotating shaft
- Measured value backlash: 0.005°
- Response threshold: 0.003°
1) Valid positional data can be read once this time has elapsed.
Electronics
- Connection type: Male connector, M23, 12-pin, radial
- Supply voltage: 10 ... 32 V
- Operating current: Typ. 60 mA
- Switching level of control inputs: Logic H = 0.7 x US, Logic L = 0 V ... 0.3 x US
- Actuation of set button: ≥ 100 ms 1)
1) Only with shaft stationary (note initialisation time).
Mechanics
- Mechanical design: Blind hollow shaft
- Shaft diameter: 15 mm 1)
- Characteristics of the shaft: Front clamp
- Weight (technical data): Approx. 0.3 kg 2)
- Housing material: Aluminum die cast
- Start up torque: Typ. 0.6 Ncm
- Operating torque: Typ. 0.4 Ncm
- Permissible movement static: ± 0.3 mm (radial); ± 0.5 mm (axial)
- Permissible movement dynamic: ± 0.1 mm (radial); ± 0.2 mm (axial)
- Operating speed: ≤ 3,000 min⁻¹
- Moment of inertia of the rotor: See figure
- Bearing lifetime: 3.6 x 109 revolutions
- Angular acceleration: ≤ 500,000 rad/s²
1) Collets for 6, 8, 10, 12, 14 mm and 1/4", 3/8" and 1/2" as accessories, separate order item. For 15 mm shaft diameter collet is not needed.
2) Based on devices with male connector.
Ambient data
- EMC: According to EN 61000-6-2 and EN 61000-6-3 1)
- Enclosure rating: IP65, male connector (IEC 60529) 2)
- Permissible relative humidity: 90 % (Condensation not permitted)
- Operating temperature range: –20 °C ... +85 °C
- Storage temperature range: –40 °C ... +100 °C, without package
- Resistance to shocks: 50 g, 11 ms (EN 60068-2-27)
- Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6)
1) EMC according to the standards quoted is achieved if shielded cables are used.
2) With mating connector fitted.
Certificates
- EU declaration of conformity: ✔
- UK declaration of conformity: ✔
- ACMA declaration of conformity: ✔
- Moroccan declaration of conformity: ✔
- China RoHS: ✔
- cULus certificate: ✔
- Information according to Art. 3 of Data Act (Regulation EU 2023/2854): ✔
Manufacturer lifecycle notice: This product is being phased out and can still be ordered until 2027-04-30.
Image is representative and may differ from the supplied item.