Description
Description of Function
Upon application of control voltage, the time delay relay is ready to accept a trigger. When the trigger is applied, the time delay (t1) begins. At the end of the time delay (t1), the output is energiezed and remains in that condition for the time delay (T2). At the end of the time delay (t2), the output is de-energized & the relay is ready to accept another another trigger. During both time delay (t1) & time delay (t2), the trigger is ignored.
Features
- Onboard & remote adjustable or fixed time delays from 0.05 seconds to 2 hours
- Independently adjustable ON & OFF times
- Uses industry-standard 11 pin octal sockets
- 10A DPDT output contacts
- Pilot Duty Rating
Specifications
- Function: Delayed Interval (Switch Trigger)
- CONTROL VOLTAGE: 12V DC
- Output: 10A DPDT
- TIMING RANGE: 0.1 – 10 Sec
- TIMING RANGE 2: 0.1 – 10 Sec
- MOUNT: 11-Pin Socket
- Setting Adjustment: Analog
- REMOTE POTENTIOMETER: Consult Factory
- REMOTE POTENTIOMETER 2: Consult Factory
- Enclosure Style: Plug-in
- Configuration / Contact Rating: DPDT 10A @ 240V AC / 10A @ 30V DC, 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.), B300 & R300
- Approvals: UL Recognized for the U.S. and Canada, CE
- DC Operation: +10/-15% of nominal
- Load (Burden): 2 VA
- Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%
- Setting Accuracy: Minimum Setting (Adjustable): +0%, -50%
- Fixed: ±2% or 50ms, whichever is greater
- Repeat Accuracy: ±0.1% or ±0.04 seconds, whichever is greater
- Reset Time: 0.04 Seconds
- Start-up Time: 0.05 Seconds
- Maintain Function Time: 0.01 Seconds
- Temperature: Operating: -28° to 65° C (-18° to 149° F)
- Temperature: Storage: -40° to 85° C (-40° to 185° F)
- Life: Mechanical: 10,000,000 operations
- Life: Full Load: 100,000 operations
Resources