Description

Description of Function

Upon application of control voltage, the time delay relay is ready to accept a trigger. When the trigger is applied, the output remains de-energized. Upon removal of the trigger, the output is energized and the time delay (t) begins. At the end of the time delay (t), the output is de-energized unless the trigger is removed and re-applied prior to time out (before time delay (t) elapses). Continuous cycling of the trigger at a rate faster than the time delay (t) will cause the output to remain energized indefinitely.

Features

  • Cost effective design & compact 2″ x 2″ enclosure are ideal for volume OEM applications
  • Microprocessor-based design for greater performance & maximum flexibility
  • Encapsulated for protection against harsh environments
  • 10A SPDT relay output contacts
  • Relay common internally connected to pin 2 for easier wiring
  • Onboard, adjustable, or fixed time delays from 0.05 seconds to 100 hours

Specifications

  • Function: Single Shot Falling Edge
  • CONTROL VOLTAGE: 240V AC
  • Output: 10A SPDT
  • TIMING RANGE: 0.1 – 10 Hrs
  • MOUNT: Single Screw Mounting
  • Setting Adjustment: Analog
  • Options: Control Voltage connected at Relay Common
  • REMOTE POTENTIOMETER: Consult Factory
  • Enclosure Style: Encapsulated
  • Configuration / Contact Rating: SPDT 10A @ 240V AC / 7A @ 28V SPDT, 1/4 HP @ 120V AC (N.O.)
  • Approvals: UL Recognized for the U.S. and Canada, CE
  • AC Operation: +10/-15% of nominal at 50/60 Hz
  • Load (Burden): 2 VA
  • Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%
  • Setting Accuracy: Minimum Setting (Adjustable): +0%, -50%
  • Fixed: ±2% or ±50ms, whichever is greater
  • Repeat Accuracy: ±0.1% or ±0.04 seconds, whichever is greater
  • Reset Time: 0.04 Seconds
  • Start-up Time: 0.05 seconds
  • Maintain Function Time: 0.01 seconds
  • Temperature: Operating: -28° to 65° C (-18° to 149° F)
  • Temperature: Storage: -40° to 85° C (-40° to 185° F)
  • Life: Mechanical: 10,000,000 operations
  • Life: Full Load: 100,000 operations
  • Mounting: Surface with one #8 or #10 screw and a maximum tightening torque of 15 in-lbs
  • Termination: 0.25″ male quick-connect terminals