Macromatic ARF024A8R

$208.89
SKU:
ARF024A8R
Shipping:
Calculated at Checkout
In Stock
Available
Before Ordering

Availability and lead times may vary. Request a quote if you need to confirm availability before placing your order.

Family Owned Since 1932
Nationwide Shipping Serving all 50 states
Technical Support Product selection assistance
Project Assistance Quotes and sourcing support

Description

Description of Function

The two loads are energized sequentially, but remain on together until the OFF switch is opened. In the initial OFF state, all three switches are open, the Alternating Relay is in the LOAD 1 position, and both loads are OFF. No action happens with the Alternating Relay or either load when the OFF Switch closes. When the LEAD Switch closes, Load M1 turns ON. When the LAG Switch closes, Load M2 turns ON. Both loads remain ON as long as all three switches are closed. When the LAG Switch opens, Load M2 remains ON because the OFF Switch is still closed. When the LEAD Switch opens, Load M1 remains ON because the OFF Switch is still closed. When the OFF Switch opens, both Load M1 and Load M2 are turned off simultaneously. The Alternating Relay toggles to the LOAD 2 position. The entire cycle is then repeated, but with Load M2 energized first followed by Load M1.

Features

  • Combines functions of alternating relay, control relay, and auxiliary contacts in one unit
  • Offers Sequence On – Simultaneous Off (S.O.S.O.) Operation with three float switch inputs
  • Protects against failures of both OFF and LEAD switches
  • Flange-enclosure designed for deadfront door-mounting
  • Low profile selector switch for normal alternation or to lock either load to be ON first
  • Two LEDs indicate relay status

Specifications

  • Function: Duplex Sequence On – Simultaneous Off
  • Control voltage: 24V AC/DC
  • Output: 5A DPDT
  • MOUNT: 8-Pin Socket
  • Setting Adjustment: Digital
  • Options: Switch to Select Normal Alternation or Lock Loads
  • Enclosure Style: Flange
  • Configuration / Contact Rating: DPDT 5A @ 120V AC/ 5A @ 24V DC B300
  • Approvals: UL Recognized for the U.S. and Canada, CE
  • AC Operation: +10/-15% of nominal at 50/60Hz
  • DC Operation: +10/-15% of nominal
  • Load (Burden): Less than 3 VA
  • Life: Mechanical: 10,000,000 operations
  • Life: Full Load: 100,000 operations
  • Temperature: Operating: -28° to 65° C (-18° to 149° F)
  • Temperature: Storage: -40° to 65° C (-18° to 149° F)
  • Optional Selector Switch Settings: LOAD1 (always energizes first), ALTERNATE, LOAD2 (always energizes first)