Description
Belden 9844 060500 RS485, 4 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM
RS-485, 4 Pair 24AWG (7x32) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, PVC Outer Jacket, CM
Ordering Details
- Manufacturer Part Number: 9844 060500
- Color: Chrome
- UPC/EAN: 612825259633
- Manufacturer Footnote: C
Product Overview
- Suitable Applications: RS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.
Construction Details
- Element: Pair(s); No. of Elements: 4; Size: 24 AWG; Stranding: 7x32; Material: TC - Tinned Copper
- Element: Pair(s); Material: PE - Polyethylene; Nom. Thickness: 0.022 in (0.56 mm); Nom. Insulation Diameter: 0.068 in (1.7 mm); Color Code: White/Blue Stripe & Blue/White Stripe, White/Orange Stripe & Orange/White Stripe, White/Green Stripe & Green/White Stripe, White/Brown Stripe & Brown/White Stripe
- Shield Type: Tape; Material: Bi-Laminate (Alum+Poly); Coverage: 100%; Drainwire Type: 24 AWG (7x32) TC
- Shield Type: Braid; Material: Tinned Copper (TC); Coverage: 90%
- Material: PVC - Polyvinyl Chloride; Nom. Thickness: 0.035 in (0.89 mm); Nom. Diameter: 0.390 in (9.91 mm)
- Outer Jacket1 Table Notes: Jacket OD +/- 0.030
- Overall Cable Diameter (Nominal): 0.390 in (9.91 mm)
Electrical Characteristics
- Element: Pair(s); Nom. Conductor DCR: 24 Ohm/1000ft; Nom. Capacitance Cond-to-Cond: 12.8 pF/ft (42.0 pF/m); Nom. Capacitance Cond-to-Other (Conds + Shield): 23 pF/ft (75 pF/m); Nom. Characteristic Impedence: 120 Ohm; Nom. Delay: 1.6 ns/ft; Nom. Velocity of Prop.: 66%; Max. Current: 1.54 Amps per Conductor at 25ºC
- Nom Outer Shield DCR: 2.1 Ohm/1000ft (6.9 Ohm/km)
- Element: Pair(s); Frequency [MHz]: 1; Nom. Insertion Loss (Attenuation): 0.6 dB/100ft
- UL Voltage Rating: 300 V (CM), 30 V (UL AWM 2919)
Mechanical Characteristics
- UL Temperature: 80°C; Operating: -30°C to +80°C
- Stationary Min.: 4 in (100 mm); Installation Min.: 4 in (100 mm)
- Max. Pull Tension: 110 lbs (50 kg)
- Bulk Cable Weight: 71 lbs/1000ft
Standards and Compliance
- Environmental Suitability: Indoor
- Flammability / Reaction to Fire: UL 1685 UL Loading, IEC 60332-1-2
- CPR Compliance: CPR Euroclass: Fca
- NEC / UL Compliance: Article 800, CM
- AWM Compliance: AWM 2919
- CEC / C(UL) Compliance: CM
- European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance: China RoHS II (GB/T 26572-2011)
History
- Update and Revision: Revision Number: 0.531 Revision Date: 02-20-2026
- Footnote: C - CRATE REEL PUT-UP.